Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies IMG-100 Inverted Magnetron Gauge

Agilent Technologies IMG-100 Inverted Magnetron Gauge — Vacuum technologies.

The IMG-100 is an inverted magnetron gauge for high-vacuum measurement, distinguished within the Agilent transducer series by its cold-cathode design that operates without a hot filament. It is intended for continuous pressure monitoring in vacuum systems where filament burnout or gas interference must be avoided, complementing thermocouple and Bayard-Alpert gauges in the same portfolio.

Agilent Technologies Vacuum Transducers Series — Model Comparison & Selection

Model Measurement rangeAtomic mass unit, gramsElectron charge, coulombMolar volume, litersMax pressure, megapascalSensitivity
IMG-100 Inverted Magnetron Gauge Current —1.66160222.41——
531 Thermocouple Gauge, Rough Vacuum Pressure Measurement —1.66160222.41——
571 Bayard-Alpert Gauge Tube -3...21.66160222.411.33×10⁻⁴17
572 Tungsten Bayard-Alpert Gauge -3...21.66160222.41-3...2—
Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge —1.66160222.41——
Hot Filament Gauge MBA2-201, Ionization BA Gauge —1.66160222.41——
IMG-300 UHV Inverted Magnetron Gauge —1.66160222.41——
UHV-24/UHV-24p 11.66160222.41—25

Full specifications

Core Performance & Functional Specifications
Electron Charge 1.602 coulomb
Molar Volume 22.41 liters
Acceleration due to gravity mfr 9.8066
Angstrom unit mfr 10 m
Avogadro's number mfr 6.02214076
Boltzmann's constant mfr 1.38064852
Equivalent of heat mfr 4.185
Natural log base mfr 2.7183
Velocity of light mfr 2.9979
Velocity of sound mfr 343
Magnetic flux density mfr 1
Pressure conversion mfr 1 Torr
Pumping speed conversion mfr 1 L/s
Throughput conversion mfr 1 cc/sec
Outgassing rate mfr 2
Dimensions, Weight & Mechanical Design
Atomic Mass Unit 1.6605 grams
Standards, Safety & General Data
Standard pressure mfr 101325 Pa

Description

Construction and series positioning

Behavior and measurement

Installation and operation

Integration & Operating Notes

Mounting
Flange and orientation details are not in the verified facts

The provided documents do not specify the IMG-100 flange type or preferred mounting orientation. The engineer must obtain the IMG-100 datasheet or manual to confirm the mating flange, insertion depth, and any orientation restriction before designing the chamber port.

Factory Specification Sheet (verified facts); document digests do not cover IMG-100
Electrical
Controller and cable requirements are not documented here

No electrical specifications (supply voltage, signal output, connector type) for the IMG-100 appear in the verified facts. Integration with a gauge controller or readout must be based on the IMG-100 product manual, not on the generic vacuum reference booklet.

Factory Specification Sheet (verified facts
Process Limits
Cold-cathode gauges are not suited to rough vacuum

Inverted magnetron gauges require high vacuum to sustain a discharge; operating at rough vacuum can cause discharge instability or contamination. The exact upper pressure limit for the IMG-100 is not stated in the verified facts and must be confirmed from the datasheet before use.

Vacuum technology reference booklet (formulas and glossary); IMG-100 datasheet required for limits
Maintenance
No filament to replace, but discharge cell cleaning is required

Cold-cathode gauges avoid filament burnout but can accumulate sputter deposits in the discharge cell over time, causing drift. The service interval and cleaning procedure for the IMG-100 are not given in the verified facts; consult the IMG-100 manual for the recommended maintenance schedule.

IMG-100 manual (not provided); general cold-cathode practice

Selection & Integration Q&A

When should I choose the IMG-100 inverted magnetron gauge instead of the 571 or 572 Bayard-Alpert gauges in the same series?

Choose the IMG-100 when filament burnout from accidental venting or reactive gases is a concern, since it has no hot filament. Choose the 571/572 Bayard-Alpert gauges when a hot-filament gauge is acceptable and a specific high-vacuum range (their key specs list -3...2 Torr) is required. The IMG-100's own range is not in the verified facts.

What controller or readout is compatible with the IMG-100, and what cable is required?

The verified facts do not list the IMG-100's electrical interface, connector, or compatible controller. The engineer must obtain the IMG-100 manual to confirm the supply voltage, signal output, and cable type; the provided portfolio leaflet covers pumps and leak detectors, not this gauge.

What are the mounting and environment limits for the IMG-100?

The verified facts contain no mounting orientation, ambient temperature, or vibration limits for the IMG-100. The attached reference booklet gives general vacuum practice but no model-specific limits. Confirm flange, orientation, and environment from the IMG-100 datasheet before installation.

What maintenance does the IMG-100 need, and what consumables or accessories are not included?

Cold-cathode gauges have no filament consumable, but the discharge cell may need periodic cleaning; the interval is not stated in the verified facts. Cables, controller, and flange hardware are not listed as included and must be ordered separately per the IMG-100 manual.