Agilent Technologies MagnisDx NGS Prep System
Agilent Technologies MagnisDx NGS Prep System — Next generation sequencing with Temperature 15 °C.
The MagnisDx NGS Prep System (K1007A) is an automated liquid-handling platform for IVD use, processing human nucleic acid samples from total RNA or fragmented gDNA through library preparation and target enrichment. It integrates a 75 °C heater, shaker, LCD touchscreen, and USB/LAN interfaces, and is validated with Agilent Magnis NGS kits. It differs from the research-use-only Magnis (G9710A) by its in vitro diagnostic labeling.
Agilent Technologies NGS Automation Platforms Series — Model Comparison & Selection
| Model | Temperature, °C | Operating temperature, °C | Acoustic pressure, dB | Electrostatic discharge immunity, volts | Labware temperature stability, °C | Library storage duration after run, hours |
|---|---|---|---|---|---|---|
| MagnisDx NGS Prep System Current | 15 | 75 | 70 | 8000 | 120 | 72 |
| Magnis NGS Prep System | 15 | 75 | 70 | 8000 | 120 | 72 |
Full specifications
| Temperature | 15 °C |
| Electrostatic Discharge Immunity | 8000 volts |
| Library Storage Duration After Run | 72 hours |
| Lifting capacity | 100 kg |
| Temperature settings | 75 °C |
| Uv Decontamination Extended Cycle Duration | 2 hours |
| Uv Decontamination Quick Cycle Duration | 30 minutes |
| Shaker maximum speed mfr | 1800 % rpm |
| Intended use mfr | Automated liquid handling system for NGS library |
| End result mfr | Target-enriched DNA library ready for sequencing |
| Validated reagents mfr | Agilent Magnis NGS kits kits |
| Materials provided mfr | Instrument with preloaded touchscreen software; |
| Cleaning supplies mfr | Alcohol wipes; dry, lint-free, scratch-free wipe |
| Dimensions, instrument door closed (H × D × W) mfr | 71 cm |
| Dimensions, instrument door open (H × D × W) mfr | 107 cm |
| Clearance, sides mfr | 4 inches |
| Clearance, back mfr | 7 inches |
| Clearance, front mfr | 2 inches |
| Clearance, top mfr | 44 inches |
| Lifting capacity for moving instrument mfr | 220 lbs |
| Maximum shaker speed mfr | 1 % tr/min |
| Maximum speed (rpm) mfr | 1800 |
| ISM Classification mfr | 1 |
| Diluted bleach (10%) wipes mfr | Surface-cleaning of the instrument deck deck |
| Alcohol (70%) wipes mfr | Surface-cleaning of the instrument exterior and |
| Dry, lint-free, scratch-free, laboratory wipes mfr | Surface-cleaning of the barcode scanner window w |
| White mfr | Ready Ready |
| Blue mfr | Ready Ready |
| Green mfr | Running Running |
| Red mfr | Error Error |
| Set up and run protocols mfr | Yes Yes |
| Update the number of PCR cycles during run setup mfr | No Yes Yes |
| Edit user accounts of other users mfr | No Yes Yes |
| Install firmware updates mfr | No Yes Yes |
| Delete diagnostic reports mfr | No Yes Yes |
| Bypass reagent expiration error mfr | No Yes* |
| Home icon mfr | Provides access to the Home screen. Press to exi |
| User name mfr | Displays the user name of the currently logged-i |
| Door status mfr | Indicates the position and lock status of the in |
| Error icon mfr | Indicates the occurrence of a system error or fa |
| Time and date mfr | Displays the time and date according to the syst |
| User Management mfr | Opens the “User Management screen” for viewing u |
| System Settings mfr | Ouvre la Fenêtre « System Settings » permettant |
| Export mfr | Opens the “Export Files screen” for exporting po |
| Auto Teaching mfr | Ouvre la Fenêtre « Auto Teach » permettant d’exé |
| Hardware Usage Tracking mfr | Ouvre la Fenêtre « Hardware Usage Tracking » per |
| Date & Time Settings mfr | Opens the “Date & Time Settings screen” for sett |
| Chiller Setting mfr | Ouvre la Fenêtre « Chiller Setting » permettant |
| Other Settings mfr | Opens the “Other Settings screen” which has a se |
| Firmware Update mfr | Opens the “Firmware Update screen” for installin |
| Lift capacity required for moving mfr | 100 kg |
| Side clearance mfr | 10 cm |
| Back clearance mfr | 18 cm |
| Chiller hold time before auto shutoff mfr | 2 hours |
| Clearance side mfr | 10 cm |
| Clearance back mfr | 18 cm |
| Clearance front mfr | 5 cm |
| Clearance top mfr | 111 cm |
| ESD threshold mfr | 8 volts |
| Module du thermocycleur mfr | Température maximale du bloc thermique thermique |
| Module chauffage/agitateur/aimant mfr | Vitesse maximale maximale |
| Module refroidisseur mfr | Plage de température rature |
| Prise d’alimentation mfr | Puissance maximale maximale |
| Connecteurs d’entrée/de sortie (E/S) mfr | Tension nominale maximale maximale |
| Système mfr | Poids Poids |
| Conditions environnementales* mfr | Altitude Altitude |
| Configuration et exécution de protocoles mfr | Oui Oui |
| Affichage des données des protocoles exécutés par eux-mêmes mfr | Oui Oui |
| Mise à jour du nombre de cycles de réaction de polymérisation en chaîne lors de la configuration du protocole mfr | Non Oui Oui |
| Affichage des données des protocoles exécutés par d’autres utilisateurs mfr | Non Oui Oui |
| Modification des comptes d’autres utilisateurs mfr | Non Oui Oui |
| Installation des mises à jour du firmware mfr | Non Oui Oui |
| Installation des mises à jour de protocoles mfr | Non Oui Oui |
| Suppression des rapports de diagnostic mfr | Non Oui Oui |
| Modification de la version par défaut des protocoles mfr | Non Oui Oui |
| Contournement de l’erreur de péremption du réactif mfr | Non Oui* |
| Date & time Settings mfr | Ouvre la Fenêtre « Date & Time Settings » permet |
| Lingettes à l'eau de Javel diluée (10 %) mfr | Nettoyage en surface du plateau de l'instrument |
| Lingettes imbibées d'alcool (70 %) mfr | Nettoyage en surface de l'extérieur et du platea |
| Lingettes de laboratoire douces, non pelucheuses et sèches mfr | Nettoyage de surface de la fenêtre du lecteur de |
| Blanc mfr | « Ready » |
| Bleu mfr | « Ready » |
| Vert mfr | « Running » |
| Rouge mfr | « Error » |
| Icône en forme de maison mfr | Permet d’accéder à la fenêtre « Home ». Appuyez |
| Nom d’utilisateur mfr | Affiche le nom de l’utilisateur actuellement con |
| État de la porte mfr | Indique la position et l’état de verrouillage de |
| UV tube lifetime mfr | 630 heures |
| Post-run chiller hold time mfr | 2 heures |
| Post-run sample hold time mfr | 72 heures |
| Lift capacity required mfr | 100 kg |
| Rear clearance mfr | 18 cm |
| Weight | 95 kg |
| Dimensions, instrument door closed (height × depth × width) mfr | 71 cm |
| Dimensions, instrument door open (height × depth × width) mfr | 107 cm |
| Dimensions, instrument door closed (Height × Depth × Width) mfr | 71 cm |
| Dimensions, instrument door open (Height × Depth × Width) mfr | 107 cm |
| Power consumption | 1000 W |
| Power supply | 100...240 VAC |
| AC voltage mfr | 100...240 |
| AC frequency mfr | 50 Hz |
| ISM classification mfr | 1 A |
| Power supply frequency mfr | 50 Hz |
| Maximum voltage rating mfr | 3.3 VDC |
| USB 2.0 port maximum voltage rating mfr | 5 VDC |
| Control interface mfr | LCD touchscreen touchscreen |
| USB 2.0 port maximum nominal voltage mfr | 5 VCC |
| LAN port maximum nominal voltage mfr | 3.3 VCC |
| LAN port maximum voltage rating mfr | 3.3 VDC |
| USB port voltage mfr | 5 VDC |
| Ethernet port voltage mfr | 3.3 VDC |
| USB 2.0 port maximum rated voltage mfr | 5 VCC |
| LAN port maximum rated voltage mfr | 3.3 VCC |
| View data from their own protocol runs mfr | Yes Yes |
| View data from protocol runs of other users mfr | No Yes Yes |
| Install protocol updates mfr | No Yes Yes |
| Change default protocol version mfr | No Yes Yes |
| Protocol Update mfr | Ouvre la Fenêtre « Protocol Update » permettant |
| Electrostatic discharge threshold affecting USB mfr | 8000 volts |
| Install firmware and protocol updates mfr | No Yes Yes |
| Starting material mfr | Total RNA or fragmented genomic DNA purified fro |
| Acoustic Pressure | 70 dBA |
| Labware Temperature Stability | 120 °C |
| Library Storage Temperature After Run | 12 °C |
| Maximum Altitude | 2000 m |
| Maximum temperature | 75 °C |
| Minimum Temperature Of Thermal Block | 4 °C |
| Sound pressure | 70 dBA |
| Operating humidity mfr | 30...70 condensing |
| Humidity mfr | 30 condensing |
| Maximum altitude for instrument operation mfr | 2000 m |
Description
Construction and series positioning
The MagnisDx NGS Prep System is the in vitro diagnostic (IVD) variant of the Magnis NGS Prep series; its sibling, the Magnis NGS Prep System (G9710A), is labeled for research use only. Both are automated liquid-handling systems intended for NGS library preparation and/or target enrichment of human nucleic acid samples. The MagnisDx is distinguished by its IVD labeling and is supplied with preloaded touchscreen software, a power cord, and a functional test certificate. The instrument includes a heater with a maximum temperature of 75 °C, a shaker, an LCD touchscreen for control, and USB 2.0 and LAN ports.
Working range and sample input
The system accepts total RNA or fragmented genomic DNA purified from cell or tissue samples, blood samples, or FFPE samples. The end result is a target-enriched DNA library ready for sequencing. Validated reagents are Agilent Magnis NGS kits. The heater supports processes up to 75 °C, and the shaker provides mixing; the maximum shaker speed is listed as 1 tr/min in the available specifications, which is insufficient to define a usable mixing range and is therefore not further characterized here.
Control, interfaces, and operation
Operation is via an LCD touchscreen with preloaded software. The USB 2.0 port has a maximum nominal voltage of 5 V, and the LAN port has a maximum nominal voltage of 3.3 V. The user guide (GEN MAN K1007 90000, 90010, 90011) covers both the Magnis and MagnisDx systems; detailed installation, connection, and operating procedures are provided in those documents. No certificates or applications are listed in the verified facts.
Integration & Operating Notes
The USB 2.0 port is rated for a maximum nominal voltage of 5 V. Connecting a device that sources or applies a higher voltage can damage the port or the instrument. Verify that any USB peripheral or adapter is compatible with this limit before connection.
The LAN port is rated for a maximum nominal voltage of 3.3 V. Use only standard Ethernet equipment that complies with this limit; non-compliant PoE injectors or miswired cables may exceed the rating and cause damage.
The heater has a maximum temperature of 75 °C. Process protocols must be validated within this limit; exceeding it may degrade samples or reagents and is outside the instrument's specified operating range.
The system is validated with Agilent Magnis NGS kits. Substituting other reagents may produce invalid results and is not supported by the IVD labeling. Ensure kit compatibility before starting a run.
The materials provided include alcohol wipes and dry, lint-free, scratch-free wipes for cleaning. Avoid abrasive or solvent-based cleaners that could damage the touchscreen or instrument surfaces. Follow the user guide for cleaning frequency and procedure.
Selection & Integration Q&A
Choose the MagnisDx (K1007A) when the workflow requires in vitro diagnostic use, as it is labeled for IVD. The Magnis (G9710A) is for research use only and must not be used for diagnostic procedures. Both automate NGS library prep and target enrichment with Agilent Magnis NGS kits.
The USB 2.0 port has a maximum nominal voltage of 5 V, and the LAN port has a maximum nominal voltage of 3.3 V. Ensure any connected device or network equipment does not exceed these ratings to avoid damage.
The base delivery includes the instrument with preloaded touchscreen software, a power cord, and a functional test certificate. Cleaning requires alcohol wipes and dry, lint-free, scratch-free wipes, which are not listed as included and must be supplied separately.