Agilent Technologies Magnis NGS Prep System
Agilent Technologies Magnis NGS Prep System — Next generation sequencing with Temperature 15 °C.
The Magnis NGS Prep System (G9710A) is a research-use-only automated liquid-handling instrument for next-generation sequencing library preparation from total RNA or fragmented genomic DNA, including blood and FFPE samples. It integrates a 75 °C heater, a shaker, and an LCD touchscreen interface, and is validated exclusively with Agilent Magnis NGS kits. It is the RUO sibling of the IVD-labeled MagnisDx (K1007A).
Agilent Technologies NGS Automation Platforms Series — Model Comparison & Selection
| Model | Temperature, °C | Operating temperature, °C | Acoustic pressure, dB | Electrostatic discharge immunity, volts | Labware temperature stability, °C | Library storage duration after run, hours |
|---|---|---|---|---|---|---|
| Magnis NGS Prep System Current | 15 | 75 | 70 | 8000 | 120 | 72 |
| MagnisDx NGS Prep System | 15 | 75 | 70 | 8000 | 120 | 72 |
Full specifications
| Temperature | 15 °C |
| Electrostatic Discharge Immunity | 8000 volts |
| Library Storage Duration After Run | 72 hours |
| Lifting capacity | 100 kg |
| Temperature settings | 75 °C |
| Uv Decontamination Extended Cycle Duration | 2 hours |
| Uv Decontamination Quick Cycle Duration | 30 minutes |
| Shaker maximum speed mfr | 1800 % rpm |
| Intended use mfr | Automated liquid handling system for NGS library |
| Validated reagents mfr | Agilent Magnis NGS kits kits |
| Materials provided mfr | Instrument with preloaded touchscreen software; |
| Cleaning supply mfr | Dry, lint-free, scratch-free wipes wipes |
| Status LED - Ready mfr | Blue Blue |
| Status LED - Running mfr | Green Green |
| Status LED - Error mfr | Red Red |
| End result mfr | Target-enriched DNA library ready for sequencing |
| Cleaning supplies mfr | Alcohol wipes; dry, lint-free, scratch-free wipe |
| Dimensions, instrument door closed (H × D × W) mfr | 71 cm |
| Dimensions, instrument door open (H × D × W) mfr | 107 cm |
| Clearance, sides mfr | 4 inches |
| Clearance, back mfr | 7 inches |
| Clearance, front mfr | 2 inches |
| Clearance, top mfr | 44 inches |
| Lifting capacity for moving instrument mfr | 220 lbs |
| Maximum shaker speed mfr | 1 % tr/min |
| Maximum speed (rpm) mfr | 1800 |
| ISM Classification mfr | 1 |
| Diluted bleach (10%) wipes mfr | Surface-cleaning of the instrument deck deck |
| Alcohol (70%) wipes mfr | Surface-cleaning of the instrument exterior and |
| Dry, lint-free, scratch-free, laboratory wipes mfr | Surface-cleaning of the barcode scanner window w |
| White mfr | Ready Ready |
| Blue mfr | Ready Ready |
| Green mfr | Running Running |
| Red mfr | Error Error |
| Set up and run protocols mfr | Yes Yes |
| Update the number of PCR cycles during run setup mfr | No Yes Yes |
| Edit user accounts of other users mfr | No Yes Yes |
| Install firmware updates mfr | No Yes Yes |
| Delete diagnostic reports mfr | No Yes Yes |
| Bypass reagent expiration error mfr | No Yes* |
| Home icon mfr | Provides access to the Home screen. Press to exi |
| User name mfr | Displays the user name of the currently logged-i |
| Door status mfr | Indicates the position and lock status of the in |
| Error icon mfr | Indicates the occurrence of a system error or fa |
| Time and date mfr | Displays the time and date according to the syst |
| User Management mfr | Opens the “User Management screen” for viewing u |
| System Settings mfr | Ouvre la Fenêtre « System Settings » permettant |
| Export mfr | Opens the “Export Files screen” for exporting po |
| Auto Teaching mfr | Ouvre la Fenêtre « Auto Teach » permettant d’exé |
| Hardware Usage Tracking mfr | Ouvre la Fenêtre « Hardware Usage Tracking » per |
| Date & Time Settings mfr | Opens the “Date & Time Settings screen” for sett |
| Chiller Setting mfr | Ouvre la Fenêtre « Chiller Setting » permettant |
| Other Settings mfr | Opens the “Other Settings screen” which has a se |
| Firmware Update mfr | Opens the “Firmware Update screen” for installin |
| Lift capacity required for moving mfr | 100 kg |
| Side clearance mfr | 10 cm |
| Back clearance mfr | 18 cm |
| Chiller hold time before auto shutoff mfr | 2 hours |
| Clearance side mfr | 10 cm |
| Clearance back mfr | 18 cm |
| Clearance front mfr | 5 cm |
| Clearance top mfr | 111 cm |
| ESD threshold mfr | 8 volts |
| Module du thermocycleur mfr | Température maximale du bloc thermique thermique |
| Module chauffage/agitateur/aimant mfr | Vitesse maximale maximale |
| Module refroidisseur mfr | Plage de température rature |
| Prise d’alimentation mfr | Puissance maximale maximale |
| Connecteurs d’entrée/de sortie (E/S) mfr | Tension nominale maximale maximale |
| Système mfr | Poids Poids |
| Conditions environnementales* mfr | Altitude Altitude |
| Configuration et exécution de protocoles mfr | Oui Oui |
| Affichage des données des protocoles exécutés par eux-mêmes mfr | Oui Oui |
| Mise à jour du nombre de cycles de réaction de polymérisation en chaîne lors de la configuration du protocole mfr | Non Oui Oui |
| Affichage des données des protocoles exécutés par d’autres utilisateurs mfr | Non Oui Oui |
| Modification des comptes d’autres utilisateurs mfr | Non Oui Oui |
| Installation des mises à jour du firmware mfr | Non Oui Oui |
| Installation des mises à jour de protocoles mfr | Non Oui Oui |
| Suppression des rapports de diagnostic mfr | Non Oui Oui |
| Modification de la version par défaut des protocoles mfr | Non Oui Oui |
| Contournement de l’erreur de péremption du réactif mfr | Non Oui* |
| Date & time Settings mfr | Ouvre la Fenêtre « Date & Time Settings » permet |
| Lingettes à l'eau de Javel diluée (10 %) mfr | Nettoyage en surface du plateau de l'instrument |
| Lingettes imbibées d'alcool (70 %) mfr | Nettoyage en surface de l'extérieur et du platea |
| Lingettes de laboratoire douces, non pelucheuses et sèches mfr | Nettoyage de surface de la fenêtre du lecteur de |
| Blanc mfr | « Ready » |
| Bleu mfr | « Ready » |
| Vert mfr | « Running » |
| Rouge mfr | « Error » |
| Icône en forme de maison mfr | Permet d’accéder à la fenêtre « Home ». Appuyez |
| Nom d’utilisateur mfr | Affiche le nom de l’utilisateur actuellement con |
| État de la porte mfr | Indique la position et l’état de verrouillage de |
| UV tube lifetime mfr | 630 heures |
| Post-run chiller hold time mfr | 2 heures |
| Post-run sample hold time mfr | 72 heures |
| Lift capacity required mfr | 100 kg |
| Rear clearance mfr | 18 cm |
| Weight | 95 kg |
| Dimensions, instrument door closed (height × depth × width) mfr | 71 cm |
| Dimensions, instrument door open (height × depth × width) mfr | 107 cm |
| Dimensions, instrument door closed (Height × Depth × Width) mfr | 71 cm |
| Dimensions, instrument door open (Height × Depth × Width) mfr | 107 cm |
| Power consumption | 1000 W |
| Power supply | 100...240 VAC |
| AC voltage mfr | 100...240 |
| AC frequency mfr | 50 Hz |
| ISM classification mfr | 1 A |
| Power supply frequency mfr | 50 Hz |
| Maximum voltage rating mfr | 3.3 VDC |
| USB 2.0 port maximum voltage rating mfr | 5 VDC |
| Control interface mfr | LCD touchscreen touchscreen |
| USB 2.0 port maximum nominal voltage mfr | 5 VCC |
| LAN port maximum nominal voltage mfr | 3.3 VCC |
| LAN port maximum voltage rating mfr | 3.3 VDC |
| USB port voltage mfr | 5 VDC |
| Ethernet port voltage mfr | 3.3 VDC |
| USB 2.0 port maximum rated voltage mfr | 5 VCC |
| LAN port maximum rated voltage mfr | 3.3 VCC |
| View data from their own protocol runs mfr | Yes Yes |
| View data from protocol runs of other users mfr | No Yes Yes |
| Install protocol updates mfr | No Yes Yes |
| Change default protocol version mfr | No Yes Yes |
| Protocol Update mfr | Ouvre la Fenêtre « Protocol Update » permettant |
| Electrostatic discharge threshold affecting USB mfr | 8000 volts |
| Install firmware and protocol updates mfr | No Yes Yes |
| Starting material mfr | Total RNA or fragmented genomic DNA purified fro |
| Acoustic Pressure | 70 dBA |
| Labware Temperature Stability | 120 °C |
| Library Storage Temperature After Run | 12 °C |
| Maximum Altitude | 2000 m |
| Maximum temperature | 75 °C |
| Minimum Temperature Of Thermal Block | 4 °C |
| Sound pressure | 70 dBA |
| Operating humidity mfr | 30...70 condensing |
| Humidity mfr | 30 condensing |
| Maximum altitude for instrument operation mfr | 2000 m |
Description
Construction and series positioning
- The Magnis (G9710A) and MagnisDx (K1007A) share the same hardware platform; the distinction is regulatory: G9710A is labeled For Research Use Only, while K1007A is For In Vitro Diagnostic Use. No other sibling variants are documented.
- The instrument is delivered with preloaded touchscreen software, a power cord, and a functional test certificate; no external PC is required for control.
- Starting material is total RNA or fragmented genomic DNA purified from cell/tissue, blood, or FFPE samples, processed with Agilent Magnis NGS kits only.
Thermal and motion behavior
- A single heater channel reaches a maximum of 75 °C (167 °F); the shaker's maximum speed is documented as 1 tr/min. No curve data or ramp rates are provided, so thermal cycling performance cannot be characterized beyond these limits.
- Status is indicated by three LEDs: blue (Ready), green (Running), red (Error).
Interfaces and electrical environment
- Control is via an LCD touchscreen. Host connectivity is through a USB 2.0 port (5 V nominal) and a LAN port (3.3 V nominal); these are logic-level interface ratings, not supply specifications.
- No supply voltage, current, or power consumption figures are given in the verified facts; the power cord is the only electrical accessory listed.
Operation and maintenance
- Cleaning requires dry, lint-free, scratch-free wipes. No service intervals, error-code tables, or consumable part numbers are available in the supplied digests.
Integration & Operating Notes
The heater maximum is 75 °C (167 °F). Any protocol requiring higher incubation temperatures cannot be run on this instrument; verify kit protocols against this ceiling before committing a workflow, since exceeding it is outside the documented operating envelope.
The instrument is validated for Agilent Magnis NGS kits with total RNA or fragmented genomic DNA from cell/tissue, blood, or FFPE samples. Third-party library prep chemistries are not covered by the documented validation and would require independent verification.
The USB 2.0 port is rated 5 V nominal and the LAN port 3.3 V nominal; these are interface voltage ratings, not instrument supply requirements. Supply voltage and current are not stated in the verified facts, so confirm them from the instrument label before site power planning.
The documented cleaning supply is dry, lint-free, scratch-free wipes. No liquid cleaning agents, service intervals, or error-code procedures are specified in the supplied documentation; the red Error LED indicates a fault state but no code table is available.
Selection & Integration Q&A
Choose G9710A for research-use-only workflows; it is labeled not for diagnostic procedures. Select K1007A only when in vitro diagnostic use is required. Both share the same platform and Agilent Magnis NGS kit chemistry, so the decision is regulatory, not technical.
It provides a USB 2.0 port (5 V nominal) and a LAN port (3.3 V nominal) plus an LCD touchscreen for local control. Only a power cord is included; USB cables, network cables, and any external PC are not part of the base delivery and must be sourced separately.
Cleaning requires dry, lint-free, scratch-free wipes. The base delivery includes the instrument with preloaded software, power cord, and functional test certificate; Agilent Magnis NGS kits, wipes, and any USB/LAN cables are not included. No service interval is specified in the supplied documentation.