No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Hot Filament Gauge MBA2-201, Ionization BA Gauge

Agilent Technologies Hot Filament Gauge MBA2-201, Ionization BA Gauge — Vacuum technologies.

The Agilent MBA2-201 is a hot-filament Bayard-Alpert ionization gauge transducer for high-vacuum measurement, distinct from the 531/536 thermocouple rough-vacuum gauges and the 571/572 gauge tubes in the same series. It is a complete transducer assembly rather than a bare tube, intended for continuous pressure indication in a pumped high-vacuum system.

Agilent Technologies Vacuum Transducers Series — Model Comparison & Selection

Model Measurement rangeAtomic mass unit, gramsElectron charge, coulombMolar volume, litersMax pressure, megapascalSensitivity
Hot Filament Gauge MBA2-201, Ionization BA Gauge Current —1.66160222.41——
531 Thermocouple Gauge, Rough Vacuum Pressure Measurement —1.66160222.41——
571 Bayard-Alpert Gauge Tube -3...21.66160222.411.33×10⁻⁴17
572 Tungsten Bayard-Alpert Gauge -3...21.66160222.41-3...2—
Cold Cathode Gauge Tube 525, High Vacuum (HV) Gauge —1.66160222.41——
IMG-100 Inverted Magnetron Gauge —1.66160222.41——
IMG-300 UHV Inverted Magnetron Gauge —1.66160222.41——
UHV-24/UHV-24p 11.66160222.41—25

Full specifications

Core Performance & Functional Specifications
Electron Charge 1.602 coulomb
Molar Volume 22.41 liters
Acceleration due to gravity mfr 9.8066
Angstrom unit mfr 10 m
Avogadro's number mfr 6.02214076
Boltzmann's constant mfr 1.38064852
Equivalent of heat mfr 4.185
Natural log base mfr 2.7183
Velocity of light mfr 2.9979
Velocity of sound mfr 343
Magnetic flux density mfr 1
Pressure conversion mfr 1 Torr
Pumping speed conversion mfr 1 L/s
Throughput conversion mfr 1 cc/sec
Outgassing rate mfr 2
Dimensions, Weight & Mechanical Design
Atomic Mass Unit 1.6605 grams
Standards, Safety & General Data
Standard pressure mfr 101325 Pa

Description

Construction and series positioning

Measurement behavior

Installation, connection and control

Integration & Operating Notes

Selection
Confirm transducer vs bare-tube need before ordering

The MBA2-201 is a transducer assembly; the 571 and 572 in the same series are Bayard-Alpert gauge tubes. If the existing system already has a transducer housing and controller, a bare tube may be the correct spare; if a complete gauge head is needed, the MBA2-201 is the matching item. The verified data do not state interchangeability, so confirm flange and pinout against the model manual.

Factory Specification Sheet; series sibling model list
Process Limits
Do not expose a hot-filament BA gauge to rough vacuum

Hot-filament Bayard-Alpert gauges are high-vacuum instruments; the sibling 571/572 tubes are specified only for the 10^-3 to 10^-2 Torr decade, and the 531/536 thermocouple gauges exist precisely for the rough-vacuum region. Starting a BA filament at elevated pressure risks filament burnout. No MBA2-201-specific pressure limit is given in the verified facts, so the switch-on threshold must be read from its own manual.

Factory Specification Sheet (sibling 571/572 ranges); series positioning
Maintenance
Filament and tube are consumable; plan spares

In a hot-filament ionization gauge the filament and the gauge tube are wear items, degraded by every exposure to higher pressure and by contamination. The verified data list no spare-part numbers or service interval for the MBA2-201, so spare filaments/tubes and any calibration service must be identified from the model manual or Agilent spare-parts documentation before commissioning.

Factory Specification Sheet; portfolio leaflet (spare parts/service options mentioned, no codes printed
Documentation
Supplied digests do not cover this model's wiring

The two attached documents are a product-portfolio leaflet and a formulas/tables reference booklet; neither prints MBA2-201 ordering codes, electrical connections, or control parameters. Electrical integration (supply, output, controller pairing) must therefore be engineered from the model-specific instruction manual, not from the attached brochures.

Document digests: 'br uhv and leak detection solutions' and 'brochure vacuum leak detection reference formulas properties glossary'

Selection & Integration Q&A

When should I specify the MBA2-201 instead of a 571/572 Bayard-Alpert tube or a 531/536 thermocouple gauge?

Pick the MBA2-201 when a complete high-vacuum transducer head is needed. A 571 or 572 tube is the choice when only the sensing tube is replaced in an existing transducer; the 572 is the tungsten-filament variant. A 531 or baffled 536 thermocouple gauge belongs on the rough-vacuum side, not in the high-vacuum measurement position.

What must I verify on the controller and flange side before connecting this gauge?

The verified facts give no flange, pinout, supply voltage, or output signal for the MBA2-201, so compatibility with the existing controller and chamber port cannot be confirmed from this data. Obtain the model instruction manual and check connector type, cable, and controller input against the gauge before mounting; do not assume the 571/572 tube interface applies.

What pressure-related operating limit applies when starting up this gauge?

A hot-filament BA gauge must not be operated at rough vacuum; the sibling 571/572 tubes are rated only for the 10^-3 to 10^-2 Torr decade, and thermocouple gauges cover the rough range. The MBA2-201's own switch-on threshold is not in the verified facts, so take it from the model manual and interlock filament-on to a proven low pressure.

What consumables and accessories are not part of the base gauge and must be planned separately?

The verified data list no cable, controller, flange hardware, spare filament, or calibration certificate as included. Treat the filament/tube as a wear item and source spares and any calibration service from Agilent documentation; the attached portfolio leaflet mentions spare parts and service options but prints no ordering codes for this model.

Dimensional Drawings & Technical Documentation

Technical documentation