Agilent Technologies Phycobiliproteins
Agilent Technologies Phycobiliproteins — Biomolecules conjugation synthesis purification.
Native phycobiliprotein fluorophore with excitation maximum at 566 nm and emission maximum at 575 nm, tetrameric molecular weight of 52 kDa, and solubility up to 50 mg/mL. Specific activity of 14.0 U/mg (HABA dye) and extinction coefficient of 240 define its use as a fluorescent label. Intended for conjugation to streptavidin or antibodies in bead-based and imaging assays.
Agilent Technologies Phycobiliprotein Series — Model Comparison & Selection
| Model | Emission maximum, nm | Excitation maximum, nm | Molecular weight tetramer size, kDa | Solubility concentration, mg/mL | Specific activity haba dye, U/mg |
|---|---|---|---|---|---|
| Phycobiliproteins Current | 575 | 566 | 52 | 50 | 14 |
| Activated Phycobiliproteins | 575 | 566 | 52 | 50 | 14 |
Full specifications
| Emission Maximum | 575 nm |
| Excitation Maximum | 566 nm |
| Solubility Concentration | 50 mg/mL |
| Specific Activity (haba Dye) | 14.0 U/mg |
| Extinction coefficient mfr | 240 |
| PJRS301*; PJRS20; PJRS34 mfr | Large Large |
| PJRS25**; PJRS27 mfr | Medium Medium |
| PJ39S mfr | Small Small |
| Streptavidin-Agarose bead size distribution mfr | 75...300 microns |
| Streptavidin-Agarose pH stability range mfr | 4...11 |
| Streptavidin-Agarose streptavidin content mfr | 1 beads |
| HRP conjugate stabilizer dilution mfr | 1000 fold |
| AP conjugate stabilizer dilution mfr | 1000 fold |
| RPE conjugation kit antibody capacity mfr | 1 mg |
| RPE conjugation kit minimum scale mfr | 50 antibody |
| RPE conjugation time mfr | as little as two hours hours |
| Molecular Weight (tetramer Size) | 52 kDa |
Description
Construction and series positioning
- This model is the unmodified phycobiliprotein (native form), distinct from activated phycobiliproteins (chemically reactive derivatives) and from pre-made conjugates such as RPE conjugates or APC conjugates.
- The tetrameric size (52 kDa) and native primary amine content make it suitable for downstream conjugation chemistry, but the user must perform the activation and coupling steps.
- Sibling models include activated phycobiliproteins (ready for direct coupling), allophycocyanin conjugates, and RPE conjugates; this native protein is the starting material for custom conjugates.
Optical and solution behavior
- Excitation maximum at 566 nm and emission maximum at 575 nm define the fluorescence channel; the small Stokes shift (9 nm) requires appropriate filter sets.
- Extinction coefficient of 240 (units not specified in the source) and specific activity of 14.0 U/mg (HABA dye) are provided for quantification of dye-to-protein ratios after conjugation.
- Solubility up to 50 mg/mL in aqueous buffer supports concentrated stock solutions for coupling reactions.
Handling and integration
- The product is supplied as a native protein; no conjugation kit or activated form is included. Users must select appropriate crosslinkers (e.g., SMCC, SPDP) and purify conjugates.
- No electrical, mounting, or control interfaces apply; integration is limited to buffer compatibility and downstream assay conditions.
- The attached document digest covers streptavidin and phycobiliprotein conjugates but provides no actionable engineering facts for this native protein; refer to the certificate of analysis for lot-specific data.
Integration & Operating Notes
Native phycobiliproteins are sensitive to extremes of pH and low ionic strength; keep solutions near neutral pH and moderate salt concentration (e.g., phosphate-buffered saline) to avoid precipitation or loss of fluorescence. Avoid freeze-thaw cycles; store concentrated aliquots at 4 °C or frozen as specified by the supplier.
Phycobiliproteins are photolabile; store protected from light and prepare working solutions immediately before use. Discard solutions showing visible turbidity or color change. No periodic maintenance schedule applies; shelf life is defined by the supplier's storage conditions.
Selection & Integration Q&A
Choose this native form when you need to perform custom conjugation chemistry (e.g., to a primary amine or thiol) and require control over the dye-to-protein ratio. Activated phycobiliproteins are pre-modified for direct coupling to antibodies or streptavidin; pre-made conjugates (RPE, APC) are ready to use but offer fixed stoichiometry.
You will need a heterobifunctional crosslinker (e.g., SMCC or SPDP), a desalting or gel-filtration column for buffer exchange, and a suitable amine-free buffer (e.g., phosphate or HEPES) at pH 7–8. For streptavidin coupling, use the SA10 native streptavidin or SA26 recombinant streptavidin-plus from the same supplier. No drive, power supply, or controller is applicable.
The base delivery is the native phycobiliprotein only; no conjugation kit, crosslinker, or purification columns are included. No scheduled maintenance is required. Consumables for conjugation (crosslinkers, desalting columns, buffers) must be purchased separately. Refer to the certificate of analysis for lot-specific storage and purity.