Agilent Technologies Smart SPME Fibers
Agilent Technologies Smart SPME Fibers — Sample preparation.
Smart SPME Fibers are 23-gauge, 10 mm fiber assemblies with a 30 µm PDMS sorption phase (0.6 µL phase volume) for nonpolar semivolatile extraction. The Smart designation adds an integrated memory chip that carries method parameters to the autosampler, distinguishing this modification from non-Smart SPME fibers in the same series. They are used as the extraction interface in GC/HPLC sample preparation workflows.
Agilent Technologies Solid Phase Microextraction Spme Series — Model Comparison & Selection
| Model | Arrow length, mm | Fiber length, mm | Pack quantity, pk | Phase thickness, µm | Sorption phase volume, microliter |
|---|---|---|---|---|---|
| Smart SPME Fibers Current | 20 | 10 | 3 | 30 | 0.6 |
| Smart SPME Arrows | Solid Phase Microextraction | 20 | 10 | 3 | 30 | 0.6 |
| SPME Fibers | 20 | 10 | 3 | 30 | 0.6 |
Full specifications
| Pack Quantity | 3 pack |
| Needle gauge mfr | 23 gauge |
| Arrow outside diameter mfr | 1.1 mm |
| SPME fiber needle gauge mfr | 23 gauge |
| SPME Arrow outside diameter mfr | 1.1 mm |
| SPME Arrow inner core diameter mfr | 0.4 mm |
| Arrow Length | 20 mm |
| Fiber Length | 10 mm |
| Phase Thickness | 30 µm |
| Sorption Phase Volume | 0.6 µL |
Description
Construction and series positioning
- This model is the Smart variant of the 10 mm SPME fiber format: 23-gauge needle, 10 mm fiber length, 30 µm phase thickness, 0.6 µL sorption-phase volume.
- It differs from the SPME Arrow sibling (20 mm arrow length, 1.1 mm or 1.5 mm outside diameter) in both geometry and format; the Arrow is a separate modification, not a longer version of this fiber.
- Within the series, the Smart (Yes/No) attribute is the distinguishing feature of this modification: the fiber carries its method information with it, whereas non-Smart fibers do not.
Phase and application behavior
- The 30 µm PDMS phase is the nonpolar semivolatile option in the documented phase set; polar volatiles are served by the 65 µm DVB/PDMS phase, which is a different fiber, not this one.
- The 0.6 µL phase volume and 30 µm film set the extraction capacity; no digitized curve points or recovery data are available for this model, so no capacity or kinetics claims are made here.
Installation and operation
- The 23-gauge needle and 10 mm fiber length define the mating autosampler/injector geometry; the 20 mm arrow length and 1.1 mm arrow OD belong to the Arrow sibling and must not be applied to this fiber.
- The supplied document digest contains no sections or actionable engineering facts on installation, control, or operating sequences, so no procedural detail is asserted beyond the verified geometry.
Integration & Operating Notes
The 23-gauge needle and 10 mm fiber length are the interface dimensions of this model. Do not substitute Arrow-format hardware (20 mm arrow, 1.1 mm OD), which belongs to the SPME Arrow sibling and will not seat correctly with this fiber.
This is the Smart variant, so method information is stored with the fiber and read by the autosampler. Verify that the autosampler/controller in use supports Smart fiber reading; non-Smart SPME fibers in the series lack this capability.
Phase selection is a process condition: the 30 µm PDMS film is documented for nonpolar semivolatiles. Polar volatiles require the 65 µm DVB/PDMS phase, a different fiber; using this fiber for that class of analytes is outside its documented scope.
Selection & Integration Q&A
Choose this fiber for 10 mm, 23-gauge fiber-format extraction of nonpolar semivolatiles with method data carried on the fiber (Smart). Choose the SPME Arrow sibling when the 20 mm arrow geometry (1.1 or 1.5 mm OD) is required; choose a non-Smart fiber only where Smart reading is not used.
The autosampler/injector must accept the 23-gauge, 10 mm fiber format, and the controller must support Smart fiber reading to use the stored method data. Arrow-format hardware (20 mm, 1.1 mm OD) is not compatible with this fiber and belongs to the separate SPME Arrow modification.
Mount it in fiber-format (23-gauge, 10 mm) hardware only; the 20 mm arrow length and 1.1 mm arrow OD are not this model's dimensions. The 30 µm PDMS phase is documented for nonpolar semivolatiles; polar volatiles call for the 65 µm DVB/PDMS fiber instead.