Solid-phase microextraction fiber assembly with a 10 mm coated length, 30 µm PDMS sorption phase (0.6 µL phase volume), mounted in a 23-gauge needle. The 20 mm arrow-length dimension and 1.1 mm arrow outside diameter define the guide/arrow geometry for direct immersion or headspace sampling. Used as the extracting element in GC/HPLC sample preparation, this nonpolar semivolatile modification sits alongside polar (65 µm DVB/PDMS) and Smart variants in the series.
Agilent Technologies Solid Phase Microextraction Spme Series — Model Comparison & Selection
| Model | Arrow length, mm | Fiber length, mm | Pack quantity, pk | Phase thickness, µm | Sorption phase volume, microliter |
|---|---|---|---|---|---|
| SPME Fibers Current | 20 | 10 | 3 | 30 | 0.6 |
| Smart SPME Arrows | Solid Phase Microextraction | 20 | 10 | 3 | 30 | 0.6 |
| Smart SPME Fibers | 20 | 10 | 3 | 30 | 0.6 |
Full specifications
| Pack Quantity | 3 pack |
| Needle gauge mfr | 23 gauge |
| Arrow outside diameter mfr | 1.1 mm |
| SPME fiber needle gauge mfr | 23 gauge |
| SPME Arrow outside diameter mfr | 1.1 mm |
| SPME Arrow inner core diameter mfr | 0.4 mm |
| Arrow Length | 20 mm |
| Fiber Length | 10 mm |
| Phase Thickness | 30 µm |
| Sorption Phase Volume | 0.6 µL |
Description
Construction and series positioning
- This model is a 10 mm fiber, not a 20 mm Arrow: the 20 mm value in the matched specs is the arrow-length dimension, while the coated fiber length is 10 mm.
- Sorption phase is 30 µm PDMS (nonpolar, semivolatile-oriented), giving a 0.6 µL phase volume; the needle is 23 gauge and the arrow outside diameter is 1.1 mm.
- Within the series, the 65 µm DVB/PDMS phase is the polar-volatile counterpart; Smart (Yes/No) and non-Smart variants, plus 3-pack and 5-pack packaging, are separate configurations — this card describes the 30 µm PDMS, 10 mm fiber only.
Behavior and media
- The 30 µm film is the thin-film option in the documented phase set, suited to semivolatile analytes; thicker or more polar phases (e.g. 65 µm DVB/PDMS) belong to other variants and should not be assumed here.
- No digitized extraction/desorption curves were supplied for this model, so no recovery, carryover or equilibration-time figures are stated.
Installation and operation
- The 23-gauge needle and 1.1 mm arrow OD set the septum-piercing and guide geometry; the 10 mm fiber length defines the exposed sorption zone during sampling.
- The attached fundamentals digest contains no actionable installation, conditioning or control facts, so no instrument-specific connection or control statements are made here.
Integration & Operating Notes
The series is documented in 3-pack and 5-pack configurations, so the fiber assembly is treated as a replaceable consumable rather than a serviceable component. No conditioning, cleaning or replacement-interval procedure is given in the supplied digest, so intervals must come from the full method documentation.
Selection & Integration Q&A
Pick this fiber for nonpolar semivolatile analytes, where the 30 µm PDMS film and 0.6 µL phase volume apply. The 65 µm DVB/PDMS phase is the documented choice for polar volatiles. Smart SPME fibers/Arrows are a separate variant family; select them only if your workflow requires the Smart configuration, which is not specified here.
The assembly presents a 23-gauge needle with a 1.1 mm arrow outside diameter and a 10 mm coated length, so the injector septum, guide and desorption port must accept 23-gauge and the 1.1 mm arrow OD. Do not size the guide for the 1.5 mm arrow OD variant. No drive, controller or power-supply interface is documented for this passive fiber.
The supplied digest gives no temperature, immersion-depth or cycle-count limits for this fiber. The only hard geometric constraints are the 23-gauge needle, 1.1 mm arrow OD and 10 mm fiber length; exceeding the guide bore or bending the needle during septum piercing is the practical risk. Consult the full method documentation for thermal and solvent limits.
The series is packaged in 3-packs and 5-packs; no conditioning vials, holders, guides or cables are listed in the supplied facts, so treat the fiber assembly as the delivered item and confirm accessories separately. No service interval or error-code procedure is documented in the digest; replacement is by swapping the consumable fiber.