Agilent Technologies Smart SPME Arrows | Solid Phase Microextraction
Agilent Technologies Smart SPME Arrows | Solid Phase Microextraction — Sample preparation.
Smart SPME Arrow with 20 mm arrow length, 10 mm fiber length, 30 µm PDMS phase (0.6 µL sorption volume), 23-gauge needle and 1.1 mm outside diameter. This modification is the nonpolar semivolatile configuration within the Smart SPME Arrow series, distinguished from 1.5 mm OD arrows and from 10 mm SPME fibers by its longer arrow body and larger sorption phase volume. It is used for headspace or direct immersion extraction of nonpolar to semivolatile analytes prior to GC or GC-MS analysis.
Agilent Technologies Solid Phase Microextraction Spme Series — Model Comparison & Selection
| Model | Arrow length, mm | Fiber length, mm | Pack quantity, pk | Phase thickness, µm | Sorption phase volume, microliter |
|---|---|---|---|---|---|
| Smart SPME Arrows | Solid Phase Microextraction Current | 20 | 10 | 3 | 30 | 0.6 |
| Smart SPME Fibers | 20 | 10 | 3 | 30 | 0.6 |
| SPME Fibers | 20 | 10 | 3 | 30 | 0.6 |
Full specifications
| Pack Quantity | 3 pack |
| Needle gauge mfr | 23 gauge |
| Arrow outside diameter mfr | 1.1 mm |
| SPME fiber needle gauge mfr | 23 gauge |
| SPME Arrow outside diameter mfr | 1.1 mm |
| SPME Arrow inner core diameter mfr | 0.4 mm |
| Arrow Length | 20 mm |
| Fiber Length | 10 mm |
| Phase Thickness | 30 µm |
| Sorption Phase Volume | 0.6 µL |
Description
Construction and series positioning
- The Smart SPME Arrow is a solid-phase microextraction device with a 20 mm arrow length and a 10 mm fiber length; the fiber is coated with a 30 µm PDMS phase giving a 0.6 µL sorption phase volume.
- The arrow body has a 1.1 mm outside diameter and a 23-gauge needle, distinguishing this modification from the 1.5 mm OD Arrow variant and from standard 10 mm SPME fibers listed as siblings.
- The 30 µm PDMS phase is the nonpolar semivolatile configuration within the series; polar volatile work uses the 65 µm DVB/PDMS phase, which is a different chemistry, not a different Arrow size.
Behavior and media
- The 0.6 µL sorption phase volume and 30 µm film thickness set the extraction capacity for nonpolar semivolatiles; the 20 mm arrow length provides a longer extraction path than the 10 mm fiber format.
- No digitized extraction-time or temperature curves were supplied with the verified facts, so recovery and equilibration behavior cannot be quantified here; method development must establish those values empirically.
Installation and operation
- The attached fundamentals document covers SPME fibers and SPME Arrows as a family, including Smart (Yes/No) and non-Smart variants and 3-pack/5-pack packaging, but contains no actionable installation, connection or control facts for this specific model.
- Consequently, autosampler compatibility, conditioning temperatures and injection parameters must be taken from the instrument-specific manual rather than inferred from this card.
Integration & Operating Notes
The 30 µm PDMS phase is intended for nonpolar to semivolatile analytes. Polar volatiles require the 65 µm DVB/PDMS phase listed in the series documentation; using the PDMS Arrow for polar volatiles will give low recovery and is a method-selection error, not an instrument fault.
This Arrow has a 1.1 mm outside diameter and 23-gauge needle, while the series also includes a 1.5 mm OD variant. The autosampler guide, septum and injector port must be sized for the 1.1 mm body; forcing a mismatched arrow can bend the arrow or damage the septum.
New SPME phases carry manufacturing residue; the Arrow must be conditioned per the phase-specific instructions and blank-run until the baseline is clean before quantitative work. The supplied fundamentals digest does not state conditioning temperatures, so the phase-specific manual must be consulted.
The series includes Smart (Yes/No) variants; the Smart feature provides automatic recognition by the instrument. Confirm which variant is being integrated, because the non-Smart version requires manual method entry of fiber type and does not report its identity to the controller.
Selection & Integration Q&A
Pick the 1.1 mm OD Arrow when the autosampler or injector accepts the smaller body and nonpolar semivolatiles are the target; the 1.5 mm OD Arrow suits wider-bore ports, and the 10 mm SPME fiber remains the lower-capacity option for standard fiber-based methods.
The autosampler guide and injector septum must accept the 1.1 mm arrow body and 23-gauge needle, and the GC inlet liner must be sized for the 20 mm arrow length. The Smart variant requires an instrument that recognizes Smart fibers; otherwise use the non-Smart variant.
The 1.1 mm OD body and 23-gauge needle are the mechanical limits: the arrow must travel through a correctly sized guide and septum, and repeated injections wear the septum and phase. The supplied digest gives no temperature or cycle-count limits, so those must come from the phase-specific manual.
The Arrow requires phase conditioning and periodic blank runs; septa, inlet liners and autosampler guides are wear items not part of the Arrow itself. The series is offered in 3-pack and 5-pack configurations, so pack size must be ordered explicitly; no cables or accessories are listed in the verified facts.