Agilent Technologies TwisTorr 305 FS
Agilent Technologies TwisTorr 305 FS — Turbomolecular Vacuum Pumps with Motor power 0.3 kW.
The TwisTorr 305 FS is a hybrid turbomolecular pump combining 8 bladed stages with 3 TwisTorr drag stages, driven by a high-frequency induction motor at up to 60600 rpm. It delivers 250 l/s N2 pumping speed and reaches 1 Torr base pressure with the recommended forepump. This FS modification is the flange-configurable platform, available in ISO 100, ISO 160, CFF 6", and CFF 8" high-vacuum connections for high and ultrahigh vacuum systems.
Direct drop-in replacements
Full specifications
| Motor power | 300 VA |
| Base Pressure With Recommended Forepump | 1 mbar |
| Pumping Speed Ar | 250 l/s |
| Pumping Speed H2 | 220 l/s |
| Pumping Speed He | 255 l/s |
| Pumping Speed N2 | 250 l/s |
| Rotational speed | 60600 rpm |
| Run-up time | 3 minutes |
| Max gas flow rate (N2) mfr | 250 sccm |
| Compression ratio N2 mfr | 1 |
| Compression ratio He mfr | 1 |
| Compression ratio H2 mfr | 1.5 |
| Compression ratio Ar mfr | 1 |
| Max Rotation Speed mfr | 60600 rpm |
| Operating position mfr | Any Any |
| Max foreline pressure tolerance N2 mfr | 12 mbar |
| Lubricant mfr | Permanent lubrication lubrication |
| Installation category mfr | II II |
| Maximum magnetic field strength axial mfr | 100 Gauss |
| Maximum magnetic field strength transversal mfr | 50 Gauss |
| Max rotation speed mfr | 60600 rpm |
| Max magnetic field axial mfr | 100 Gauss |
| Max magnetic field transversal mfr | 50 Gauss |
| Max gas flow rate (N2): mfr | 250 sccm |
| Vent Valve Extension cable (5 m) mfr | 9699941 |
| X3506-64130 mfr | 305 |
| X3506-64131 mfr | 305 Profibus |
| X3513-64008 mfr | 305 COOLING |
| X3513-64009 mfr | 305 COOLING |
| X3513-64010 mfr | 305 COOLING |
| X3513-64011 mfr | 305 COOLING |
| X3513-64012 mfr | 305 COOLING |
| X3513-64013 mfr | 305 COOLING |
| X3513-64014 mfr | 305 COOLING |
| X3513-64015 mfr | 305 COOLING |
| shelf life mfr | 12 months |
| ISO-K clamp torque mfr | 22 Nm |
| ConFlat screw torque mfr | 20 Nm |
| Weight Pump CFF 6" mfr | 8.16 kg |
| Weight Pump CFF 8" mfr | 10.43 kg |
| Pump stand-by average power mfr | 10 W |
| Pump max operating power mfr | 150 W |
| Pwr supply : mfr | 300 W |
| X3507-64130 mfr | 305 V |
| X3507-64131 mfr | 305 V |
| Inlet flange | 8 O.D. |
| Foreline flange mfr | 16 NW |
| Turbopump extension cable (for remote controller only) mfr | 9699942 |
| Vent Valve N.O. 0,5 mm Orifice (for remote controller only) mfr | 9699844 |
| Vent Valve N.O. 1,2 mm Orifice (for remote controller only) mfr | 9699845 |
| Vent Valve N.C. 0,5 mm Orifice (for remote controller only) mfr | 9699847 |
| Vent Valve N.C. 1,2 mm Orifice (for remote controller only) mfr | 9699846 |
| Mains Cable CHINA plug (3 m long) mfr | 8121 |
| high-vacuum flange torque mfr | 1000 Nm |
| Coolant Water Minimum Flow | 50 l/h |
| Coolant water max pressure mfr | 5 bar |
| Bakeout Temperature | 75 °C |
| Noise Pressure Level | 41 dB |
| Operating Altitude | 3000 m |
| Operating temperature | 5 °C |
| Storage temperature | -40 °C |
| Relative humidity of air mfr | 13 |
| Air cooling requirements mfr | Natural convection Forced air air |
| Pollution degree mfr | 2 |
| Small TMP air cooling kit ext cable (5 m) mfr | 9699940 |
| maximum ambient pressure mfr | 2 pressure |
| Weight Pump ISO 100 K mfr | 5.84 kg |
| Weight Pump ISO 160 K mfr | 6.28 kg |
Description
Construction and series positioning
- Hybrid rotor: 8 bladed turbine stages plus 3 TwisTorr drag stages, ceramic ball bearings on the fore-vacuum side.
- One pump platform, eight orderable models differing only by high-vacuum flange: ISO 100 (X3513-64008), CFF 6" (X3513-64009), ISO 160, and CFF 8".
- Pump weights track the flange: 5.84 kg (ISO 100 K), 6.28 kg (ISO 160 K), 8.16 kg (CFF 6"), 10.43 kg (CFF 8").
- Permanent bearing lubrication; no oil system to service.
Behavior across gases and operating modes
- Pumping speed is nearly gas-independent: 250 l/s N2, 250 l/s Ar, 255 l/s He, 220 l/s H2.
- Maximum N2 gas flow 250 sccm; foreline pressure tolerance for N2 is 12 mbar, the point at which the pump still produces a compression of 100.
- Start-up is under 3 minutes, but soft start extends this; soft start is mandatory at first ramp-up and after 60 days or more of inactivity to ensure bearing lubrication.
- Rotor fatigue life is 405000 full ramp cycles; Agilent recommends return after 17 years.
Installation, connection, and control
- The pump may be mounted in any position but must be fixed against a 1000 Nm torque around its axis in case of rotor failure; use bolts of resistance class 8.8 or higher.
- ISO-K flanges use 4 claw clamps at 22 Nm; ConFlat flanges use 16 screws (CFF 6") or 20 screws (CFF 8") at 20 Nm, tightened sequentially.
- Foreline flange is NW 16; recommended forepumps are DS102, DS302, IDP-3 (no gas flow), IDP-7, and IDP10.
- Controller options: onboard 24 V (X3507-64130), onboard 110/230 V (X3507-64131), AG Remote RS232/485 (X3506-64130), AG Remote Profibus (X3506-64131).
- Cooling is forced air by default; water cooling kits 9699337 (metallic) and 9699347 (plastic) require >50 l/h flow, +15 to +30 °C, max 5 bar, conductivity ≤500 µs/cm.
- A separate earth conductor (M5 x 10 screw, 2 Nm) must give <0.1 Ω impedance between pump body and earth point.
Integration & Operating Notes
The installation must withstand a torque of 1000 Nm around the pump axis in the event of rotor failure. Use only high-resistance-class clamps or bolts (≥ 8.8) and follow the specified tightening torques; the pump can be mounted in any position, but the fixing is not optional.
The maximum foreline pressure tolerance for N2 is 12 mbar, defined as the pressure at which the turbopump still produces a compression of 100. Size and operate the forepump so the foreline stays below this limit under the actual gas load, otherwise pumping performance degrades.
Soft start mode is mandatory at the first ramp-up and after 60 days or more of inactivity to ensure proper bearing lubrication. If a new pump is paired with a used controller, set soft start manually and wait for full speed before stopping the pump.
Install a dedicated earth conductor using the M5 x 10 screw and shake-proof washer tightened to 2 Nm. The impedance between the pump body and the earth point must be less than 0.1 Ω; this is a safety requirement, not a performance tuning step.
Water cooling kits require flow >50 l/h, water temperature +15 to +30 °C, maximum pressure 5 bar, and conductivity ≤500 µs/cm. In closed circuits with higher conductivity, use up to 20% ethyl glycol; tighten the kit into the pump body to 5 Nm.
For corrosive and oxidizing gases, inert purge gas must flow around the upper bearing to the forevacuum line at 0.1 to 0.8 mbar l/s, with a minimum of 10 sccm (0.17 mbar l/s). Install the purge valve with 2.5 Nm torque after switching off the pump.
Rotor fatigue resistance is 405000 cycles of ramp up from stop to full speed and back to stop; Agilent also recommends return after 17 years of use. Log cycle counts and calendar age to plan maintenance or replacement, since the pump itself requires no routine maintenance.
Maximum allowed magnetic field is 100 Gauss (10 mT) axial and 50 Gauss (5 mT) transversal. Operating ambient temperature is +5 °C to +35 °C; if the pump is stored below 5 °C, wait until it reaches operating temperature before switching on.
Selection & Integration Q&A
All eight models share the same rotor and performance; the choice is the high-vacuum flange. Pick ISO 100 or ISO 160 for elastomer-sealed ISO-K systems with claw clamps at 22 Nm; pick CFF 6" or CFF 8" for metal-sealed ConFlat systems needing 16 or 20 screws at 20 Nm and bakeout to 100 °C instead of 75 °C.
Recommended forepumps are DS102, DS302, IDP-3 (no gas flow), IDP-7, and IDP10, connected to the NW 16 foreline flange. Controllers are onboard 24 V (X3507-64130), onboard 110/230 V (X3507-64131), or AG Remote RS232/485 (X3506-64130) and Profibus (X3506-64131). Max input power is 300 VA.
Yes, any operating position is allowed, but the fixing must withstand 1000 Nm around the axis in case of rotor failure. Keep ambient at +5 to +35 °C, magnetic field below 100 Gauss axial / 50 Gauss transversal, and observe bakeout limits of 75 °C (ISO) or 100 °C (CFF) at the inlet flange.
The pump needs no routine maintenance, but plan return at 405000 ramp cycles or 17 years. Accessories ordered separately include air cooling kits X3500-68010/X3500-68011, water cooling kits 9699337/9699347, vent valves (e.g. 9699834, 9699844), purge valves, inlet screens, vibration isolators (9699344/9699345/9699334/9699335), and the KF25 foreline flange.