Agilent Technologies UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments

Agilent Technologies UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments — Molecular spectroscopy.

The 4200 FlexScan is a handheld FTIR spectrometer in Agilent's Onsite Analysis series, distinguished from the 4300/4500/5500 siblings by its handheld form factor for field deployment. It performs diffuse and total reflection measurements using an external DRA, with setup in under five minutes. Primary purpose is on-site molecular identification where laboratory transport is impractical.

Agilent Technologies Molecular Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAbsorbance error, %Atr path length, µmAtr surface diameter, mmCertified absorbance value of filter
UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments Current ——0.189——0.369
Fluorescence Spectroscopy Instrumentation, Spectrofluorometers 900—————
FTIR Spectroscopy Equipment 5100...6000.02—2.62.5—
LDIR Chemical Imaging, IR & Imaging Spectroscopy ——————

Full specifications

Core Performance & Functional Specifications
Absorbance Error 0.1894 %
Certified Absorbance Value Of Filter 0.3688 Abs
Integrating Sphere Diameter 50 mm
Measured Absorbance (cary 7000) 0.3694 Abs
Sphere Size 50 mm
Setup time mfr less than five minutes minutes
Minimum sample size (w × h), filter holder mfr 12 mm
Maximum sample size (w × h), filter holder mfr 50 mm
DRA type mfr Internal Internal
Compatible instrument mfr 60 Vis
Measurement capability mfr Diffuse/total reflection reflection
Absorbance accuracy requirement below 1 Abs mfr 0.01
Absorbance accuracy requirement above 1 Abs mfr 1
Certified absorbance tolerance of filter mfr 0.0025 Abs
Standards, Safety & General Data
Maximum Sample Thickness, Standard Clamp Holder 5 mm
Minimum sample size (w × h), standard clamp holder mfr 15 mm

Description

Construction and series positioning

Measurement behavior

Installation and operation

Integration & Operating Notes

Mounting
Sample size must match the selected holder

The standard clamp holder accepts 15–200 mm samples up to 5 mm thick, while the filter holder accepts only 12–50 mm samples. Verify sample dimensions against the installed holder before measurement; using the wrong holder will prevent proper seating and invalidate the reflection reading.

Factory Specification Sheet
Process Limits
Absorbance accuracy degrades above 1 Abs

The accuracy requirement is 0.01 below 1 Abs but relaxes to 1 above 1 Abs. Samples with absorbance above 1 Abs will carry substantially larger uncertainty; dilute or attenuate high-absorbance samples if quantitative results are required.

Factory Specification Sheet
Control & I/O
External DRA is a separate accessory

The 50 mm integrating sphere DRA is external to the spectrometer and must be fitted before reflection measurements. Confirm the DRA is included in the delivery configuration; the base instrument alone does not provide diffuse reflectance capability.

Factory Specification Sheet
Maintenance
Verify absorbance accuracy with certified filters

Periodic checks against metal-on-quartz filter reference materials (certified tolerance 0.0059 Abs) confirm photometric accuracy. The 0.1894% absorbance error observed on the Cary 7000 reference indicates the expected agreement level; schedule filter checks per your quality system.

Technical Overview, Cary 7000 NIR Photometric Accuracy

Selection & Integration Q&A

When should I choose the 4200 FlexScan over the 4300 or 4500 portable FTIR models?

Choose the 4200 FlexScan for true handheld field work where setup under five minutes and external DRA reflection measurements on samples up to 200 mm are needed. The 4300 and 4500 are portable/compact units better suited to bench-adjacent or vehicle-based use; the 5500 is a compact laboratory instrument.

What adjacent equipment must be specified with the 4200 FlexScan for reflection measurements?

An external DRA with a 50 mm integrating sphere is required for diffuse/total reflection; it is not integral to the base unit. For NIR work the compatible instrument is the Cary 5000. Confirm DRA inclusion and holder type (standard clamp vs filter) at order time.

What sample and environmental limits apply during field deployment?

Samples must fit the installed holder: 15–200 mm and ≤5 mm thick with the standard clamp, or 12–50 mm with the filter holder. Absorbance above 1 Abs carries a relaxed accuracy requirement of 1, so high-absorbance samples need dilution or attenuation for quantitative work.

What maintenance and consumables are needed beyond the base delivery?

The external DRA and sample holders are separate accessories; confirm they are ordered. Periodic accuracy verification uses metal-on-quartz filter reference materials with 0.0059 Abs certified tolerance. No 4200-specific service intervals are documented in the available digests; follow the instrument manual.