Elmo Rietschle 2BH20540
Elmo Rietschle 2BH20540 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270 mbar, Motor power 4.6 kW, Noise level 71 dB.
The 2BH20540 is a side-channel regenerative blower in the Elmo Rietschle G-BH2 series, driven by a 4.6 kW IE3 motor rated for 190–210 V at 50 Hz or 200 V at 60 Hz. It delivers up to 170 mbar gauge pressure or -210 mbar vacuum, positioning it between the smaller 2BH20360 and larger 2BH20780 siblings. Its primary role is oil-free conveying, pressure, or vacuum generation in industrial processes.
Elmo Rietschle G-BH2 Series — Model Comparison & Selection
Full specifications
| Max. differential pressure | -270 mbar (50 Hz) 60 Hz: -210 mbar |
| Motor power | 4.6 kW (50 Hz) 60 Hz: 5.3 kW |
| Noise level | 67 dB (50 Hz) 60 Hz: 71 dB |
| Order No. mfr | 2BH20540-1AAK... |
| Certification mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Max. differential pressure vacuum mfr | -210 mbar |
| Max. differential pressure (alt 50 Hz) mfr | 240 mbar (50 Hz) |
| Max. differential pressure (alt 60 Hz) mfr | 170 mbar (60 Hz) |
| Weight | 83 kg |
| Number of stages | 1 |
| Current | 17.1 A (50 Hz) 60 Hz: 19.6 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 V |
| Motor efficiency class mfr | IE3 |
| Rated current mfr | 19.6 A (50 Hz) |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Sound pressure level mfr | 67 dB(A) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with an IE3 efficiency-class motor, IP55 protection, and class F insulation.
- Operates on 50/60 Hz with voltage windows of 190–210 V (50 Hz) and 200 V (60 Hz); rated current is 19.6 A at 50 Hz and 17.1 A at 60 Hz.
- Weighs approximately 83 kg and carries UL 1450 and CAN/CSA C22.2 No. 68-09 certification (certificate E225239).
- Within the G-BH2 series, this model sits between the 2BH20360 and 2BH20780, offering a mid-range pressure/vacuum capability.
Performance behavior
- Maximum differential pressure is 170 mbar in pressure mode and -210 mbar in vacuum mode, with a sound pressure level of 67 dB(A).
- No digitized curve points are available in the supplied facts; refer to the manufacturer’s performance curves for flow-dependent behavior.
- The blower is oil-free and contactless, making it suitable for continuous duty in clean media; avoid abrasive or corrosive gases unless specifically rated.
Installation and operation
- No PDF digests were provided; installation, connection, and control specifics must be taken from the official instruction manual.
- The motor is designed for direct-on-line or star-delta starting; verify supply impedance and protection coordination for the 19.6 A rated current.
- Ensure adequate ventilation and ambient temperature limits per manual; the IP55 rating permits outdoor use but not immersion.
Integration & Operating Notes
Exceeding the upper voltage limit can overflux the motor and cause overheating; operating below the lower limit reduces starting torque and may trip overload protection. Verify site voltage and use a suitable transformer if the grid deviates.
Selection & Integration Q&A
Choose the 2BH20540 when your required pressure or vacuum falls between the capacities of the 2BH20360 and 2BH20780. It offers a balanced 4.6 kW motor and 170/-210 mbar limits, avoiding oversizing of the larger unit or underperformance of the smaller one.
The motor requires a 190–210 V supply at 50 Hz or 200 V at 60 Hz, with rated current of 19.6 A (50 Hz) or 17.1 A (60 Hz). Use a motor protection circuit breaker or overload relay set to these currents, and ensure the supply can handle starting inrush.
The IP55 motor allows dusty and damp environments but not immersion. Ambient temperature limits and duty cycle are detailed in the manual; typically continuous duty at rated load is permissible up to 40°C. Ensure adequate ventilation and avoid corrosive atmospheres.
Regular maintenance includes checking the impeller for debris, inspecting bearings every 10,000 hours, and verifying electrical connections. The base delivery excludes suction/discharge silencers, filters, and flexible connectors; these must be ordered separately as needed.