Elmo Rietschle 2BH20780
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH20780

Elmo Rietschle 2BH20780 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -220 mbar, Motor power 6.3 kW, Noise level 75 dB.

The 2BH20780 is a side-channel (regenerative) blower from the Elmo Rietschle G-BH2 series, configured as a single unit with IP55 protection and class F insulation. It operates on 50/60 Hz with ±10% voltage and ±2% frequency tolerance, distinguishing it from smaller siblings 2BH20360 and 2BH20540 by its larger frame size. It serves as a vacuum or pressure source in pneumatic conveying, drying, or aeration systems where oil-free, pulsation-free air is required.

Max. differential pressure
-220 mbar
Motor power
6.3 kW
Noise level
75 dB
Weight
120 kg

Elmo Rietschle G-BH2 Series — Model Comparison & Selection

Model Max. differential pressure, mbarMotor power, kWNoise level, dBWeight, kgCurrent, AVoltage, V
2BH20780 Current -2207.37012027.6190–210
2BH20360 -2002.567569.9190-210 / 380-420
2BH20540 -2105.3678319.6190–210

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -220 mbar
60 Hz: -150 mbar
Motor power 6.3 kW (50 Hz)
60 Hz: 7.3 kW
Noise level 70 dB (50 Hz)
60 Hz: 75 dB
Typ Nr. mfr 2BH20780-1AAQQ3-BA
Frequenz mfr 60 Hz
Zulassungen mfr UL 1450, CAN/CSA 22.2 No 68-09
Spannungstoleranz mfr ± 10 %
Frequenztoleranz mfr ± 2 %
Typ mfr 2BH20780-1
Max. Differenzdruck Vakuum mfr -150 mbar (50 Hz)
Max. Differenzdruck Verdichter mfr 120 mbar (50 Hz)
Effizienzklasse mfr IE3 (50 Hz)
Bestell-Nr. mfr 2BH20780-1AAKM1-BA
Max. Differenzdruck Vakuum mfr -150 mbar (60 Hz)
Max. Differenzdruck Verdichter mfr 120 mbar (60 Hz)
Effizienzklasse mfr NP (60 Hz)
Max. Differenzdruck Verdichter (alt var) mfr 200 mbar
Max. Differenzdruck Verdichter (alt 60 Hz) mfr 120 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 120 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 27.6 A (60 Hz (190-210 VYY / 380-420 VY))
60 Hz (200 VYY): 27.6 A
Frequency 50 Hz (50 Hz)
60 Hz: 60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 V
Strom mfr 27.6 A (50 Hz YY)
Strom mfr 13.8 A (50 Hz Y)
Leistung mfr 7.3 kW (50 Hz)
Strom mfr 27.6 A (60 Hz YY)
Strom mfr 13.8 A (60 Hz Y)
Leistung mfr 7.3 kW (60 Hz)
voltage (alt 50 Hz) mfr 380-420 V (50 Hz)
voltage (alt 60 Hz) mfr 200 V (60 Hz)
Strom (alt 60 Hz (190-210 VYY / 380-420 VY)) mfr 13.8 A (60 Hz (190-210 VYY / 380-420 VY))
Operating Conditions, Environment & Protection
Protection rating IP55
Schalldruckpegel mfr 75 dB(A) (50 Hz)
Schalldruckpegel mfr 75 dB(A) (60 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and control

Integration & Operating Notes

Electrical
Supply voltage must stay within ±10% of nominal

Exceeding the ±10% voltage tolerance can cause motor overheating, reduced insulation life, or failure of the integrated thermal protection. The ±2% frequency tolerance also applies; operation outside these limits voids the UL/CSA approvals and may damage the motor windings.

Factory Specification Sheet
Mounting
Install on a flat, rigid surface to avoid vibration

The blower must be mounted horizontally on a foundation that dampens vibration; uneven or flexible mounting can lead to bearing wear, increased noise, and premature failure. Ensure sufficient clearance for cooling air intake and exhaust.

Instruction Manual, Section 3 Mounting
Process Limits
Do not exceed maximum pressure or vacuum ratings

Operating beyond the maximum permissible pressure or vacuum (as per the performance curve) can cause motor overload, excessive temperature rise, and mechanical damage. The blower has no internal relief valve; system design must include external protection.

Instruction Manual, Section 5 Operation
Maintenance
Inspect and clean the impeller and filters regularly

Accumulation of dust or debris on the impeller can cause imbalance and vibration. The maintenance schedule in the manual specifies periodic cleaning and bearing inspection; in dusty environments, shorten intervals accordingly.

Instruction Manual, Section 7 Maintenance

Selection & Integration Q&A

When should I choose the 2BH20780 over the smaller 2BH20360 or 2BH20540?

Choose 2BH20780 when your required flow or pressure exceeds the capacity of the smaller siblings. It offers higher performance but also larger dimensions and power draw; verify the system curve against the 2BH20780 performance data.

What are the requirements for the electrical supply and protection when integrating this blower?

The motor requires a 50/60 Hz supply within ±10% voltage and ±2% frequency. Use a motor protection circuit breaker or VFD with proper settings; ensure the supply can handle the starting current. The IP55 terminal box must be sealed with appropriate cable glands.

What maintenance is required and what consumables are not included in the base delivery?

Regular maintenance includes cleaning the impeller and checking bearings. Consumables like filters, gaskets, and bearings are not included; order separately. The manual specifies intervals based on operating hours and environment.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH207801 IE3 compressor (DE)
Datasheet ·287,3 КБ ·2 pp.
View PDF