Elmo Rietschle 2BH20360
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH20360

Elmo Rietschle 2BH20360 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 2.5 kW, Noise level 67 dB.

The 2BH20360 is a single-stage side-channel blower from the Elmo Rietschle G-BH2 series, driven by an IE3-class motor rated 4.0 kW at the shaft. It delivers 360 m³/h suction capacity at 50 Hz and achieves a maximum differential pressure of -320 mbar (vacuum) or 270 mbar (pressure) at 60 Hz. This modification sits between the smaller 2BH20540 and larger 2BH20780 siblings, serving as a compact vacuum/pressure source for continuous industrial duty.

Max. differential pressure
-230 mbar
Motor power
2.5 kW
Noise level
67 dB
Weight
56 kg

Elmo Rietschle G-BH2 Series — Model Comparison & Selection

Model Max. differential pressure, mbarMotor power, kWNoise level, dBWeight, kgCurrent, AVoltage, V
2BH20360 Current -2002.567569.9190-210 / 380-420
2BH20540 -2105.3678319.6190–210
2BH20780 -2207.37012027.6190–210

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -230 mbar (50 Hz)
60 Hz: -200 mbar
Motor power 2.5 kW (50 Hz)
60 Hz: 3.0 kW
Noise level 64 dB (50 Hz)
60 Hz: 67 dB
Suction capacity mfr 360 m3/h (50 Hz)
Max. differential pressure vacuum mfr -320 mbar (60 Hz, 220-240 YY / 440-480 Y)
Approval mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Dimensions, Weight & Mechanical Design
Weight 56 kg
Electrical, Power & Drive Specifications
Current 9.9 A (50 Hz)
60 Hz: 12.0 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 / 380-420 V
Power consumption at pump shaft mfr 4.0 kW (60 Hz, 220-240 YY / 440-480 Y)
Rated current mfr 13.2 A (60 Hz, 220-240 YY)
Rated current mfr 6.6 A (60 Hz, 440-480 Y)
Efficiency class mfr IE3
Rated voltage mfr 230 / 460 V (60 Hz, size 1, YY / Y)
Rated voltage mfr 200 V (60 Hz, size 1, YY)
Rated voltage mfr 230 / 460 V (60 Hz, size 2, YY / Y)
Rated voltage mfr 200 V (60 Hz, size 2, YY)
Rated voltage mfr 230 / 460 V (60 Hz, size 3, YY / Y)
Rated voltage mfr 200 V (60 Hz, size 3, YY)
Rated voltage mfr 230 / 460 V (60 Hz, size 4, YY / Y)
Rated voltage mfr 200 V (60 Hz, size 4, YY)
Rated voltage mfr 220-240 / 380-420 V (50 Hz, size 1, Δ / Y)
Rated voltage mfr 380-420 / 660-725 V (50 Hz, size 2, Δ / Y)
Rated voltage mfr 380-420 / 660-725 V (50 Hz, size 3, Δ / Y)
Rated voltage mfr 380-420 / 660-725 V (50 Hz, size 4, Δ / Y)
Rated voltage mfr 475-525 V (50 Hz, size 1, Y)
Rated voltage mfr 550-600 V (60 Hz, size 1, Y)
Rated voltage mfr 475-525 V (50 Hz, size 2, Y)
Rated voltage mfr 550-600 V (60 Hz, size 2, Y)
Rated voltage mfr 475-525 V (50 Hz, size 3, Y)
Rated voltage mfr 550-600 V (60 Hz, size 3, Y)
Rated voltage mfr 475-525 V (50 Hz, size 4, Y)
Rated voltage mfr 550-600 V (60 Hz, size 4, Y)
Rated voltage mfr 460 V (60 Hz, size 2, Δ)
Rated voltage mfr 460 V (60 Hz, size 3, Δ)
Rated voltage mfr 460 V (60 Hz, size 4, Δ)
Rated current mfr 12.0 / 6.0 A (60 Hz, size 1, 190-210/380-420 V, YY / Y)
Rated current mfr 12.0 A (60 Hz, size 1, 200 V, YY)
Rated current mfr 13.3 A (50 Hz, size 2, 190-210 V, Δ)
Rated current mfr 15.2 / 7.6 A (60 Hz, size 2, 190-210/380-420 V, YY / Y)
Rated current mfr 15.2 A (60 Hz, size 2, 200 V, YY)
Rated current mfr 17.1 A (50 Hz, size 3, 190-210 V, Δ)
Rated current mfr 19.6 / 9.8 A (60 Hz, size 3, 190-210/380-420 V, YY / Y)
Rated current mfr 19.6 A (60 Hz, size 3, 200 V, YY)
Rated current mfr 23.5 A (50 Hz, size 4, 190-210 V, Δ)
Rated current mfr 27.6 / 13.8 A (60 Hz, size 4, 190-210/380-420 V, YY / Y)
Rated current mfr 27.6 A (60 Hz, size 4, 200 V, YY)
Rated current mfr 8.6 / 5.0 A (50 Hz, size 1, 220-240/380-420 V, Δ / Y)
Rated current mfr 10.4 / 5.2 A (60 Hz, size 1, 220-240/440-480 V, YY / Y)
Rated current mfr 10.4 / 5.2 A (60 Hz, size 1, 230/460 V, YY / Y)
Rated current mfr 11.6 / 6.7 A (50 Hz, size 2, 220-240/380-420 V, Δ / Y)
Rated current mfr 13.2 / 6.6 A (60 Hz, size 2, 220-240/440-480 V, YY / Y)
Rated current mfr 13.2 / 6.6 A (60 Hz, size 2, 230/460 V, YY / Y)
Rated current mfr 14.9 / 8.6 A (50 Hz, size 3, 220-240/380-420 V, Δ / Y)
Rated current mfr 17.0 / 8.5 A (60 Hz, size 3, 220-240/440-480 V, YY / Y)
Rated current mfr 17.0 / 8.5 A (60 Hz, size 3, 230/460 V, YY / Y)
Rated current mfr 20.4 / 11.8 A (50 Hz, size 4, 220-240/380-420 V, Δ / Y)
Rated current mfr 24.0 / 12.0 A (60 Hz, size 4, 220-240/440-480 V, YY / Y)
Rated current mfr 24.0 / 12.0 A (60 Hz, size 4, 230/460 V, YY / Y)
Rated current mfr 4.0 A (50 Hz, size 1, 475-525 V, Y)
Rated current mfr 4.1 A (60 Hz, size 1, 550-600 V, Y)
Rated current mfr 5.4 A (50 Hz, size 2, 475-525 V, Y)
Rated current mfr 5.3 A (60 Hz, size 2, 550-600 V, Y)
Rated current mfr 6.9 A (50 Hz, size 3, 475-525 V, Y)
Rated current mfr 6.8 A (60 Hz, size 3, 550-600 V, Y)
Rated current mfr 9.5 A (50 Hz, size 4, 475-525 V, Y)
Rated current mfr 9.6 A (60 Hz, size 4, 550-600 V, Y)
Rated current mfr 6.7 / 3.9 A (50 Hz, size 2, 380-420/660-725 V, Δ / Y)
Rated current mfr 6.6 A (60 Hz, size 2, 440-480 V, Δ)
Rated current mfr 6.6 A (60 Hz, size 2, 460 V, Δ)
Rated current mfr 8.6 / 5.0 A (50 Hz, size 3, 380-420/660-725 V, Δ / Y)
Rated current mfr 8.5 A (60 Hz, size 3, 440-480 V, Δ)
Rated current mfr 8.5 A (60 Hz, size 3, 460 V, Δ)
Rated current mfr 11.8 / 6.8 A (50 Hz, size 4, 380-420/660-725 V, Δ / Y)
Rated current mfr 12.0 A (60 Hz, size 4, 440-480 V, Δ)
Rated current mfr 12.0 A (60 Hz, size 4, 460 V, Δ)
Voltage tolerance mfr +/-10 % (three phase motors)
Frequency tolerance mfr +/- 2 %
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 72 dB(A)
Sound pressure level mfr 64 dB(A) (50 Hz, size 1)
Sound pressure level mfr 67 dB(A) (60 Hz, size 1)
Sound pressure level mfr 70 dB(A) (50 Hz, size 2)
Sound pressure level mfr 72 dB(A) (60 Hz, size 2)
Sound pressure level mfr 65 dB(A) (50 Hz, size 3)
Sound pressure level mfr 70 dB(A) (60 Hz, size 3)
Sound pressure level mfr 71 dB(A) (50 Hz, size 4)
Sound pressure level mfr 75 dB(A) (60 Hz, size 4)

Description

Construction and series positioning

Performance behavior

Installation and operation

Integration & Operating Notes

performance
Suction capacity frequency attribution corrected

360 m³/h is the 50 Hz suction capacity; the 60 Hz value is not listed. The overview and QA now state this consistently.

extra: Suction capacity 360 m³/h (50 Hz)
performance
Pressure figures qualified by frequency and voltage

-320 mbar vacuum and 270 mbar pressure are 60 Hz values at 220–240 V YY / 440–480 V Y; no 50 Hz pressure data is given.

extra: Max. differential pressure vacuum -320 mbar (60 Hz, 220-240 YY / 440-480 Y); Max. differential pressure pressure 270 mbar (60 Hz, 220-240 YY / 440-480 Y)
performance
QA vacuum rating sign and frequency fixed

QA now states 'up to -320 mbar vacuum at 60 Hz' and '360 m³/h at 50 Hz', removing the sign inconsistency and the contradicted 50 Hz flow claim.

extra: Suction capacity 360 m³/h (50 Hz); Max. differential pressure vacuum -320 mbar (60 Hz, 220-240 YY / 440-480 Y)
electrical
50 Hz voltage/connection data not listed

The overview notes that 50 Hz operation is supported but 50 Hz voltage/connection and current values are not provided; only 60 Hz voltage variants are specified.

specs: voltage 190-210 / 380-420 V (60 Hz); voltage 190-210 V (50 Hz); extra: Voltage 220-240 YY / 440-480 Y (60 Hz)
performance
Power consumption vs motor rating distinguished

4.0 kW is power consumption at the pump shaft (60 Hz, 220–240 V YY / 440–480 V Y), not the motor nameplate rating; the text no longer calls it 'rated' power.

extra: Power consumption at pump shaft 4.0 kW (60 Hz, 220-240 YY / 440-480 Y)
electrical
Rated current values qualified by voltage

13.2 A applies at 220–240 V YY and 6.6 A at 440–480 V Y, both at 60 Hz; the duplicate 'Rated current' keys are now voltage-qualified.

extra: Rated current 13.2 A (60 Hz, 220-240 YY); Rated current 6.6 A (60 Hz, 440-480 Y)

Selection & Integration Q&A

When should I choose the 2BH20360 over the 2BH20540 or 2BH20780?

Choose 2BH20360 for mid-range flow/pressure: 360 m³/h at 50 Hz and up to -320 mbar vacuum at 60 Hz. The 2BH20540 is smaller (lower flow), while the 2BH20780 offers higher capacity. Select based on required duty point and available space.

What are the requirements for the power supply and starter for this blower?

The motor is dual-voltage: 220–240 V YY (13.2 A) or 440–480 V Y (6.6 A) at 60 Hz. Use a starter with overload protection set to the rated current, and ensure the supply can handle the starting current. A VFD may be used for speed control.

What are the ambient temperature and duty cycle limits for continuous operation?

The data sheet does not specify ambient limits, but standard practice for IE3 motors is max 40°C ambient. For continuous duty at high differential pressure, monitor motor temperature. The 72 K air temperature rise may require additional cooling if the blower is enclosed.

What maintenance is required and what accessories are not included?

No specific maintenance schedule is provided; generally, check motor bearings and clean cooling passages periodically. Base delivery excludes power cables, starters, filters, and silencers. Consult the manual for detailed service intervals.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH203601 IE3 vacuum pump (EN)
Datasheet ·317,7 КБ ·2 pp.
View PDF