Elmo Rietschle 2BV3151
Elmo Rietschle 2BV3151 — Liquid Ring Vacuum Pumps.
The 2BV3151 is a liquid-ring vacuum pump in the L-2BV series, achieving an ultimate pressure of 33 mbar abs. with a nominal operating-liquid flow of 0.65 l/min. It is distinguished from siblings by its G3/8 inlet/discharge ports and 9 kg weight, serving as a compact solution for self-priming or operating-liquid-fed vacuum systems.
Elmo Rietschle L-2BV Series — Model Comparison & Selection
| Model | Max inlet pressure, kPa | Operating principle | Weight, kg | Noise level, dB | Operating temperature, °C | Pumping speed, m³/h |
|---|---|---|---|---|---|---|
| 2BV3151 Current | — | Liquid ring vacuum pump | 9 | 70 | — | — |
| L-2BV 3151 | 3.3 | — | 9 | 70 | 110 | 39 |
| L-2BV 7060 | 130 | liquid-ring | 25 | 70 | 80 | — |
Full specifications
| Operating principle | Liquid ring vacuum pump |
| Ultimate pressure | 33 mbar abs. |
| Weight | 9 kg |
| Power supply | AC |
| Noise level | 70 dB(A) (50 Hz) 60 Hz: 70 dB(A) |
| Protection rating | IP55 |
Description
Construction and Series Positioning
The 2BV3151 is a liquid-ring vacuum pump from the Elmo Rietschle L-2BV series. It weighs 9 kg and has an IP55-rated motor. The pump is optimized for vacuum generation with an ultimate pressure of 33 mbar abs. This model uses G3/8 inlet and discharge connections, G1/8 operating-liquid and cavitation-protection ports, and a G1/8 drain hole.
Operating Behavior and Limits
- The pump can operate in self-priming mode or with operating-liquid feed (non-automatic or automatic). In self-priming mode, the inlet must be pre-throttled to at least 80 kPa abs. at switch-on, and the liquid level in the reservoir must be at shaft center initially, not dropping below approximately 1 m below shaft center during operation.
- For operation with operating-liquid feed, the pre-pressure should be set to approximately inlet pressure + 100 kPa, or the flow rate adjusted to the nominal 0.65 l/min using a flow meter or graduated vessel.
- The maximum pumped gas temperature is +110 °C, while operating-liquid and ambient temperatures must remain between +5 and +40 °C. Without cavitation protection, the minimum inlet pressure is 5 kPa abs.; with cavitation protection, the maximum achievable vacuum can be reached.
- Maximum discharge pressure during vacuum operation is 110 kPa abs.
Installation and Operation
Installation requires a minimum clearance of 20 mm from the fan guard to adjacent surfaces for cooling, and the mounting surface must support the 9 kg weight. The pump must be installed so that vibration velocity does not exceed 4.5 mm/s. Electrical connection requires a motor circuit breaker set to the rating plate current, and supply voltage/frequency deviations must stay within ±5% and ±2%, respectively. Pipe connections must be tightened to the specified torques: G3/8 to 16 Nm ±10%, G1/8 to 4.5 Nm ±10%. A check valve is recommended when connecting to a vacuum accumulator, and a start-up screen should be installed in the inlet pipe for the first 100 operating hours.
Integration & Operating Notes
Insufficient clearance can cause overheating and reduced service life. Ensure at least 20 mm (0.787 in) between the fan guard and any adjacent surface to allow adequate cooling airflow.
During vacuum operation, the maximum discharge pressure is 110 kPa abs. (16.0 psia). Exceeding this limit may damage the pump or cause leakage. Install pressure relief or monitoring if the system can exceed this value.
Operating below 5 kPa abs. without cavitation protection can lead to cavitation damage. If lower pressures are required, ensure cavitation protection is installed or consult the manufacturer.
The motor circuit breaker must be set to the nominal current specified on the motor rating plate to provide correct overload protection. Verify the setting before commissioning.
A start-up screen in the inlet pipe prevents installation residues from entering the pump during the initial operating period. Remove or clean the screen after 100 hours to avoid flow restriction.
For operation with operating-liquid feed, adjust the flow rate to the nominal 0.65 l/min using a flow meter or graduated vessel. Incorrect flow can affect vacuum performance and cause cavitation or overheating.
Selection & Integration Q&A
Choose the 2BV3151 for vacuum duty with an ultimate pressure of 33 mbar abs. and G3/8 ports.
Use G3/8 mating fittings for inlet and discharge, tightened to 16 Nm ±10%. Install a check valve if connecting to a vacuum accumulator to prevent liquid ingress. For the first 100 hours, install a start-up screen in the inlet pipe.
The base delivery does not include a start-up screen, check valve, or operating-liquid flow meter; these must be procured separately. Regular maintenance includes checking operating-liquid flow and condition, and inspecting the start-up screen for the first 100 hours.