Elmo Rietschle VSI 100
Elmo Rietschle VSI 100 — Screw Vacuum Pumps with Motor power 3.6 kW, Pumping speed 138 m³/h, Ultimate pressure 0.1 mbar.
The VSI 100 is a dry-running, non-contact screw vacuum pump with oil-lubricated gearbox and bearings, separating the compression chamber from the drive. It delivers 110 m³/h at 50 Hz (138 m³/h at 60 Hz) and an ultimate pressure of 0.1 mbar, positioning it as the smallest model in the VSI series, distinct from the higher-capacity VSI 300 and VSI 301. It is intended for continuous evacuation or vacuum holding in closed systems up to 80 liters, with water cooling as standard.
Elmo Rietschle VSI Series — Model Comparison & Selection
Full specifications
| Motor power | 3.0 kW (50 Hz) 60 Hz: 3.6 kW |
| Pumping speed | 110 m³/h (50 Hz) 60 Hz: 138 m³/h |
| Ultimate pressure | 0.1 mbar |
| Rotational speed | 2880 rpm (50 Hz) 60 Hz: 3550 rpm |
| Height | 404 mm |
| Length | 1082 mm |
| Weight | 190 kg |
| Width | 543 mm |
| Inlet flange | G 1 1/2 |
| Oil capacity | 1.65 l |
| Noise level | 72 dB (50 Hz) 60 Hz: 75 dB |
Description
Construction and series positioning
- The VSI 100 uses a double-shaft screw rotor principle with non-contact, dry-running rotors; the gearbox and bearings are oil-lubricated and sealed from the compression chamber.
- Within the VSI series, the VSI 100 is the smallest variant: its G 1 1/2 vacuum connection and 110 m³/h (50 Hz) capacity contrast with the VSI 300 (G 2 1/2, 320 m³/h) and VSI 301 (300 m³/h, 0.08 mbar ultimate). The VSI 301 is distinguished from the VSI 300 by its lower ultimate pressure, not by higher capacity.
- Standard cooling is continuous-flow water cooling; a circulation cooling option (30 l tank, 101/131 kg) is available but adds significant weight and footprint.
Behavior under load and media
- The pump is rated for continuous intake pressures between 0.1 and 1000 mbar (abs.), enabling both closed-system evacuation and continuous vacuum operation.
- Maximum pumping capacity with free suction is 110 m³/h at 50 Hz and 138 m³/h at 60 Hz; capacity depends on intake pressure (refer to data sheet D 832).
- Permissible outlet counter pressure is < +0.2 bar for the standard (01) variant; exhaust piping must be sized accordingly.
- Ambient and suction temperatures must remain between 5 and 40 °C; operation outside this range requires manufacturer consultation.
Installation, connection and control
- The vacuum connection is G 1 1/2; pipes must be screwed in by hand only. For connection pipes of the same cross-section and longer than 3 m, a non-return valve (ZRK) must be installed to prevent reverse operation after stop.
- Cooling water connections require 1.8 l/min at a maximum cooling-water temperature of 50 °C; operating pressure must not exceed 6 bar, and water temperature must be 15–50 °C. Anti-freeze (min. 10%) is required where freezing conditions can occur.
- The motor is available for 230/400 V ±10% (50 Hz) and 220/380 V (60 Hz) or 380/660 V (60 Hz). Without derating, a voltage deviation of ±5% and a frequency deviation of ±2% are permissible; verify that the mains supply matches the motor data plate before connection.
- Oil fill is 1.65 l (1.0 l at H + 0.65 l at H1) of ISO VG 150 CLP HC 150 oil; fill to the middle of the inspection glasses.
Integration & Operating Notes
When evacuating a closed system, the volume to be evacuated must be max. 80 l. Larger volumes require a different evacuation strategy or consultation with the manufacturer, as exceeding this limit may lead to overheating or inadequate evacuation performance.
The permissible outlet counter pressure for the S-VSI 100 (01) is < +0.2 bar. Exhaust piping, silencers, and any downstream components must be sized so that this limit is not exceeded during operation, otherwise pumping capacity and motor load may be adversely affected.
The cooling water operating pressure must not exceed 6 bar; if supply pressure can exceed this value, install a pressure regulation valve or safety valve. Cooling water temperature must be between 15 and 50 °C, and consumption is 1.8 l/min at a maximum cooling-water temperature of 50 °C. Mix with at least 10% anti-freeze where freezing conditions can occur.
Provide sufficient clearance around the pump for cooling-water connections and maintenance access. When installed at more than 1000 m above sea level, a reduction in power is noticeable; contact the manufacturer for high-altitude applications.
Without derating, ±5% voltage deviation and ±2% frequency deviation are permissible. Verify that the mains supply matches the motor data plate before connection. The motor is available for 230/400 V ±10% (50 Hz) and 220/380 V (60 Hz) or 380/660 V (60 Hz).
Oil change interval is every 7,500 operating hours with clean operations. Check oil level monthly. Use only ISO VG 150 CLP HC 150 oil (GEAR-LUBE 150 or equivalent); if changing oil type, empty the oil tank completely. Correct oil quantity for S-VSI 100 is 1.65 l (1.0 l at H + 0.65 l at H1); fill to the middle of the inspection glasses.
Operation outside this range requires consultation with the manufacturer. Ensure that the installation location maintains ambient temperature within this range and that the suction gas temperature does not exceed 40 °C.
With connection pipes of the same cross-section as the machine connection and more than 3 m long, a non-return valve (ZRK) must be installed. This prevents reverse operation when the machine has stopped.
Selection & Integration Q&A
Choose the VSI 100 for lower pumping speeds up to 110 m³/h (50 Hz) and smaller systems with G 1 1/2 connections. The VSI 300 offers 320 m³/h and G 2 1/2, while the VSI 301 provides 300 m³/h and a lower ultimate pressure of 0.08 mbar. Select the VSI 100 when its capacity and ultimate pressure of 0.1 mbar suffice and space or cooling water is limited.
Cooling water operating pressure must not exceed 6 bar; install a pressure regulation valve if necessary. Water temperature must be 15–50 °C, and consumption is 1.8 l/min at a maximum cooling-water temperature of 50 °C. Mix with at least 10% anti-freeze where freezing conditions can occur. The optional circulation cooling uses G 3/4 connections; the standard continuous-flow cooling connection size is not specified in the provided documentation—consult the manufacturer or data sheet D 832 for exact connection dimensions.
Provide sufficient clearance around the pump for cooling-water connections and maintenance access. Ambient and suction temperature must be between 5 and 40 °C; operation outside this range requires manufacturer consultation. At altitudes above 1000 m, a reduction in power is noticeable; contact the manufacturer for high-altitude applications.
The base delivery does not include oil (ISO VG 150 CLP HC 150, 1.65 l required), cooling water fittings, or a non-return valve (ZRK) for long pipes. Maintenance includes oil changes every 7,500 hours, monthly oil level checks, coupling inspection, and cooling system maintenance. Air filter and gas ballast filter cleaning are not mentioned in the provided engineering overview or notes; consult the operating instructions for their existence and service interval. Spare parts are listed in the Spare Parts List E 832.