Peter Huber Kältemaschinenbau HB240 Umwälz-Heizgerät
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau HB240 Umwälz-Heizgerät

Peter Huber Kältemaschinenbau HB240 Umwälz-Heizgerät — Thermostatic baths.

The HB240 is a 24 kW, 400 V three-phase heating bath circulator for external open operation, delivering 60–250 °C with a magnetically coupled stainless-steel pump (up to 100 l/min, 3.5 bar). It has no expansion tank, so the external application must provide filling and volume compensation. It is the mid-high capacity unit in the HB series, positioned between the HB120 and HB480.

Direct drop-in replacements

Eppendorf
MixMate ®
82%
match
⚖️ Compare

Peter Huber Kältemaschinenbau Umwaelz Heizgeraete Series — Model Comparison & Selection

Model Dimensions w d hPower supplyPump connectionPump typeHeating capacity, WAmbient temperature limit, °C
HB240 Umwälz-Heizgerät Current 570 x 700 x 1171400V 3~ 50HzM30x1, 5 AG malemagnetically coupled, st240005–40
HB120 Umwälz-Heizgerät 479 x 539 x 695380-460V 3~ 50/60HzM30x1, 5 AG malemagnetically coupled, st—5–40
HB480 Umwälz-Heizgerät 570 x 700 x 1171400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st480005–40
HB60 Umwälz-Heizgerät 323 x 451 x 498400V 3~N 50HzM30x1, 5 AG malePressure pump, speed not60005–40
HB720 Umwälz-Heizgerät 800 x 1007 x 1607400V 3~ 50HzM38x1, 5 AG malemagnetically coupled, st720005–40

Full specifications

Core Performance & Functional Specifications
Dimensions (w × D × H) 570 x 700 x 1171 mm
Heating capacity 24 kW
Pump connection M30x1, 5 AG male
Pump speed adjustable Yes
Pump type magnetically coupled, stainless steel
External sensor connection Pt100
Temperature range 60...250 °C
Electrical, Power & Drive Specifications
Power supply 400V 3~ 50Hz
Interfaces, Connections & Control
Controller Pilot ONE
Display resolution 0, 01 K
Digital interface Ethernet, USB (Host u. Device), RS232
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Standards, Safety & General Data
Safety class II / FL

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
External circuit must provide filling and volume compensation

Because the HB240 has no expansion tank and is designed exclusively for external open operation, the external application must supply the filling volume and compensate for thermal expansion; otherwise the unit cannot operate correctly.

Datasheet, Overview
Electrical
Cable supplied without plug; customer provides 3-phase plug

The unit is delivered with a cable but without a plug for three-phase devices under 63 A, so the customer must provide a suitable 400 V three-phase plug and connection by a qualified electrician.

Datasheet, Technical Specifications
Process Limits
Minimum 60 °C depends on application heat loss of 0.1–2.8 kW

To reach the 60 °C minimum temperature, ambient must be below 60 °C and the external application heat loss must fall between 0.1 kW and 2.8 kW depending on the HB model; outside this window the minimum temperature may not be achieved.

Datasheet, Technical Specifications
Electrical
EMC class A group 1: industrial environment only

The unit is classified EMC class A, group 1 to EN 55011, so it may cause radio interference in residential areas and is intended for industrial environments; consider EMC coordination if installed near sensitive electronics.

Datasheet, Technical Specifications
Electrical
Account for leakage current from external temperature control

Leakage current from the external temperature control must be considered when selecting protective devices and earthing; proper earthing and RCD selection are required.

Datasheet, Technical Specifications
Process Limits
Check external circuit pressure drop against 3.5 bar / 100 l/min

The circulation pump delivers up to 100 l/min at up to 3.5 bar; the pressure drop of the external application must be checked to ensure the pump can overcome it.

Datasheet, Technical Specifications
Control & I/O
Set adjustable overtemperature protection for the application

The unit has adjustable overtemperature protection according to DIN 12876 and safety classification II/FL; the installer must configure the limit to protect the external application and fluid.

Datasheet, Technical Specifications

Selection & Integration Q&A

When should I choose the HB240 rather than the HB120 or HB480?

Choose the HB240 when 24 kW heating and 60–250 °C suit your load; the HB120 offers lower capacity and the HB480 higher. The HB240 sits between them in the series, so match heating power and pump duty to your application heat loss and circuit pressure drop.

What must I provide for the external circuit and power connection to integrate the HB240?

Provide an external open circuit with filling and volume compensation (no expansion tank on the unit), hoses or adapters with M30x1.5 female thread, and a 400 V 3~ 50 Hz supply with a suitable plug (cable supplied without plug). Verify voltage/frequency within ±10% without opposing deviation.

What maintenance and accessories are required that are not included in the base delivery?

The base delivery includes a cable but no plug, so a 400 V three-phase plug is required. No maintenance schedule or consumables are specified in the available datasheet; use stainless-steel-compatible thermofluid and cleaning agents, and set the adjustable overtemperature protection for the application.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
HB240 Heating Bath Circulator
Datasheet ·17,6 КБ ·2 pp.
View PDF