Nabertherm F 30
Nabertherm ·Made in Germany · In Active Production

Nabertherm F 30

Nabertherm F 30 — Fusing furnaces.

The Nabertherm F 30 is a top-loading fusing furnace with a 410 × 410 × 230 mm chamber and 950 °C maximum temperature, powered by a 2 kW single-phase connection. It is the smallest model in the F-series, positioned below the F 75 and F 110 for low-throughput fusing and glass melting where floor space is limited to 0.13 m².

Nabertherm Top Loader as Fusing Furnaces | Nabertherm Series — Model Comparison & Selection

Model Electrical connectionWeight, kgMax temperature, °C
F 30 Current 1-phase55950
F 110 3-phase110950
F 75 3-phase95950

Full specifications

Core Performance & Functional Specifications
Electrical connection 1-phase
Nominal power 2 kW
Floor space mfr 0.13
Inner dimensions (W × D × H) mfr 410 × 410 × 230 mm
Outer dimensions (W × D × H) mfr 640 × 770 × 585 mm
Dimensions, Weight & Mechanical Design
Weight 55 kg
Operating Conditions, Environment & Protection
Max temperature 950 °C

Description

Construction and series positioning

Thermal behavior and process role

Control and integration

Integration & Operating Notes

Control & I/O
Controller and process data recording are separate selections

The furnace does not include a controller in the base scope. Nabertherm offers the series 500 controllers and MyNabertherm app for programming and data logging. The specific controller model and any required thermocouples or interface modules must be ordered separately and matched to the 950 °C maximum temperature.

Prozesssteuerung englisch, controller functions
Process Limits
Chamber load must not exceed 950 °C or obstruct lid seal

Operating above 950 °C risks damage to heating elements and insulation. Loads must be placed to avoid contact with the lid seal or heating elements when the lid is closed. The chamber dimensions (410 × 410 × 230 mm) define the maximum charge size; overloading can cause uneven heating and premature element failure.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the F 30 instead of the F 75 or F 110?

Choose the F 30 for small batches or low-throughput fusing where the 410 × 410 × 230 mm chamber and 950 °C limit are sufficient and floor space is tight (0.13 m²). The F 75 and F 110 offer larger chambers but require more space and power; select them only if you need higher capacity.

What controller and power supply components are required to operate the F 30?

The F 30 requires a single-phase 2 kW supply and a separate controller. Nabertherm's series 500 controllers or MyNabertherm app can be used for programming and data logging. Ensure the controller supports type K or appropriate thermocouples for 950 °C and that the supply circuit is dedicated and properly fused.

What maintenance and accessories are needed for the F 30, and what is not included?

Base delivery excludes controller, thermocouples, and process recording accessories. Periodic maintenance includes checking heating elements and door seal, and calibrating the controller. No specific maintenance interval is given in the verified facts; refer to the manual for recommended schedules.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF