Nabertherm N 81
Nabertherm N 81 — Prozesse Unter Luft.
The N 81 is a 3-phase electrically heated chamber furnace with an 80-litre chamber (500 × 750 × 250 mm W×D×H) rated to 1200 °C. Within the N-series it is the mid-size 1200 °C modification, distinct from the 1300 °C N 81/13 and the higher-temperature /H siblings. It serves batch heat treatment under air in industrial processes.
Nabertherm Chamber Furnaces electrically heated | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 80 l |
| Chamber volume | 80 l |
| Chamber volume | 80 l |
| Chamber volume | 80 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 20.0 |
| Inner dimensions (W × D × H) mfr | 500 × 750 × 250 mm |
| Outer dimensions (W × D × H) mfr | 1300 × 2000 × 2000 mm |
| Weight | 950 kg |
| Weight | 950 kg |
| Weight | 950 kg |
| Weight | 950 kg |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
| Max temperature | 1200 °C |
Description
Construction and series positioning
- Chamber volume 80 l; inner dimensions 500 × 750 × 250 mm (W × D × H); outer dimensions 1300 × 2000 × 2000 mm; weight 950 kg.
- Electrically heated, 3-phase connection; maximum temperature 1200 °C.
- Sibling models define the series envelope: N 41/H and N 87/H are the /H (higher-temperature) variants, while N 81/13 is the 1300 °C version of the same 81 size. The N 81 is therefore the 1200 °C, 80-litre member of the family.
Behavior and media
- The category path places the unit in processes under air; no curve points or atmosphere data were supplied, so no load-dependent or atmosphere-specific behavior is asserted here.
- The only thermal limit documented is the 1200 °C maximum temperature; no heating-rate or uniformity figures are available for this model.
Control and operation
- The attached controller digest covers the Nabertherm 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but it prints no furnace-specific settings for the N 81. Controller configuration must therefore be taken from the unit's own wiring and commissioning documents, not from the generic digest.
Integration & Operating Notes
The maximum temperature is 1200 °C. The sibling N 81/13 reaches 1300 °C and the /H models are the higher-temperature variants; if the process recipe requires more than 1200 °C, this modification is the wrong selection and the workload must be moved to a sibling.
Selection & Integration Q&A
Pick the N 81 when the recipe tops out at 1200 °C and an 80-litre chamber (500 × 750 × 250 mm) fits the batch. Choose N 81/13 if 1300 °C is needed; choose N 41/H or N 87/H when the /H higher-temperature variant or a different chamber size is required.
The furnace is a 3-phase load, so a three-phase feed with matching protection is required. The verified facts give no current or power rating; size cables and breakers from the unit nameplate and its circuit diagram, not from this card.
The controller digest covers 500-series controllers, the MyNabertherm app, process-data storage and AMS2750F instrumentation options, but does not state what is in the N 81 base delivery. Confirm controller model, thermocouples, recorder and interface cables as line items before ordering.