Nabertherm NAT 50/85 — Forced Convection.
The NAT 50/85 is a 50-litre forced-convection chamber furnace in Nabertherm's tabletop NAT series, electrically heated to 850 °C and connected via 3-phase supply. Its 400 × 320 × 400 mm chamber and 4.5 kW heating distinguish it from smaller 15- and 30-litre siblings, suiting batch heat treatment where forced air circulation is required.
Nabertherm NAT Series — Model Comparison & Selection
Full specifications
| Chamber volume | 50 l |
| Chamber volume | 50 l |
| Chamber volume | 50 l |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Electrical connection | 3-phase |
| Heating mfr | 4,5 |
| Heat-up time3 mfr | 230 |
| Inner dimensions (W × D × H) mfr | 400 × 320 × 400 mm |
| Outer dimensions (W × D × H) mfr | 770 × 880 × 820 mm |
| Weight | 130 kg |
| Weight | 130 kg |
| Weight | 130 kg |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
The NAT 50/85 is the mid-capacity tabletop unit of the NAT forced-convection chamber furnace line, with a 50 l working volume and a maximum temperature of 850 °C. It sits above the NAT 15/85 and NAT 30/85 in chamber size and below the larger floor-standing variants; the 30/65 sibling trades temperature for a lower 650 °C ceiling. The chamber measures 400 mm wide × 320 mm deep × 400 mm high, and the outer envelope is 770 × 880 × 820 mm at 130 kg.
Thermal behaviour and media
Heating is electric with a 4.5 kW installed load; the factory heat-up time to working temperature is listed as 230 (unit not stated in the source, so treat as a relative figure only). Forced convection is the defining feature of the series: an internal fan circulates the chamber atmosphere to reduce temperature gradients across the load. No digitized curve points were supplied, so no cooling-rate or uniformity curve is asserted here.
Control and operation
Controller and process-data functions are covered by Nabertherm's separate controller documentation (series 500 and MyNabertherm app), not by a model-specific manual in the supplied digests. The furnace is a 3-phase unit; no voltage or current rating is stated in the verified facts, so the electrical design must be confirmed against the nameplate before installation.
Integration & Operating Notes
Process control, data storage and recorder options are described in Nabertherm's controller documentation (series 500 and MyNabertherm app), not in a model-specific manual. Specify the controller and any recorder or AMS2750F instrumentation type at order time, since these are not defined by the NAT 50/85 furnace data alone.
Selection & Integration Q&A
Pick the NAT 50/85 when the batch needs the full 400 × 320 × 400 mm, 50 l chamber at up to 850 °C. The 30/85 and 15/85 offer smaller chambers at the same temperature ceiling; choose them only if the load fits, since the 50/85's larger volume and 4.5 kW load are wasted on small batches.
The unit is 3-phase with a 4.5 kW heating load, but the verified data gives no voltage or current. Obtain the nameplate rating for the delivered variant and size the feeder, breaker and earthing to it; do not infer current from the kW figure alone.
The verified facts list only the furnace itself: no controller, recorder, thermocouple, cable or process-data option is included in the base data. Controller and MyNabertherm functions are documented separately, so specify controller, recorder and any AMS2750F instrumentation at order time.