The W 1500/14 is a bogie hearth furnace with a 1500 l chamber (900 × 1900 × 900 mm) and wire heating to 1400 °C, built for loads up to 3500 kg. It is the mid-size 1400 °C modification in the W series, positioned between the W 1500 and W 5000 variants for batch heat treatment on a rail-mounted hearth.

Nabertherm Bogie Hearth Furnaces with Wire Heating up to 1400 °C | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LHeating power, WMax temperature, °CWeight, kgElectrical connection
W 1500/14 Current 1500110140035003-phase
W 1500 150075128035003-phase
W 5000 5000185128073003-phase
W 5000/H 5000235134073003-phase
W 7500/H 75003701340103003-phase

Full specifications

Core Performance & Functional Specifications
Chamber volume 1500 l
Electrical connection 3-phase
Heating power 110 watt
Inner dimensions (W × D × H) mfr 900 × 1900 × 900 mm
Outer dimensions (W × D × H) mfr 1570 × 2690 × 2020 mm
Dimensions, Weight & Mechanical Design
Weight 3500 kg
Operating Conditions, Environment & Protection
Max temperature 1400 °C

Description

Construction and series positioning

Thermal behaviour

Control and operation

Integration & Operating Notes

Control & I/O
Controller and recorder are separate selections from the furnace

Nabertherm controller series 500 and the MyNabertherm app provide process-data storage and temperature-uniformity instrumentation, and recorder/controller options are documented separately. Specify the controller, recorder and any AMS2750F instrumentation type at order time; they are not defined by the furnace model code alone.

Prozesssteuerung englisch (controller series 500 and MyNabertherm app
Maintenance
Obtain the W 1500/14 manual before defining service intervals

The supplied document digests cover controllers, fiber-optics glass furnaces, foundry furnaces and dental furnaces, none of which are this model. Maintenance intervals for wire-heating elements, hearth drive and door seals, and the list of consumables and accessories not included in base delivery, must be taken from the W 1500/14 instruction manual and spare-parts list.

Document digests (no W 1500/14 manual supplied

Selection & Integration Q&A

When should I choose the W 1500/14 rather than the W 1500 or W 5000 siblings?

Pick the W 1500/14 when the batch fits a 900 × 1900 × 900 mm chamber and the 3500 kg furnace class is acceptable at 1400 °C. The W 1500 is the smaller chamber; the W 5000 and W 7500 are larger, so move up only if the workload exceeds the 1500 l envelope.

What supply and protection does the 3-phase connection require?

The specs give only '3-phase' with no voltage or current, and the 110 W heating-power entry is inconsistent with this size, so do not size from it. Take voltage, full-load current and breaker rating from the nameplate and wiring diagram, and provide a lockable isolator near the furnace.

What is not included in base delivery that I must plan for?

Controller series 500, MyNabertherm app connectivity, recorders and AMS2750F instrumentation are separate selections, and the supplied digests contain no W 1500/14 manual, spare-parts list or accessory schedule. Obtain the model manual and order controller, recorder and consumables explicitly.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF