Nabertherm W 7500/H
Nabertherm ·Made in Germany · In Active Production

Nabertherm W 7500/H

Nabertherm W 7500/H — Furnace Solutions 1400 Degc.

The W 7500/H is a bogie hearth furnace with a 7500-litre chamber (1000 × 5400 × 1400 mm) and wire heating for a maximum temperature of 1340 °C. Its 5400-mm depth distinguishes it from the shorter W 5000/H and W 1500 variants in the series. It is intended for batch heat treatment of long or bulky loads that are charged on a rail-mounted bogie.

Nabertherm Bogie Hearth Furnaces with Wire Heating up to 1400 °C | Nabertherm Series — Model Comparison & Selection

Model Chamber volume, LHeating power, WMax temperature, °CWeight, kgElectrical connection
W 7500/H Current 75003701340103003-phase
W 1500 150075128035003-phase
W 1500/14 1500110140035003-phase
W 5000 5000185128073003-phase
W 5000/H 5000235134073003-phase

Full specifications

Core Performance & Functional Specifications
Chamber volume 7500 l
Electrical connection 3-phase
Heating power 370 watt
Inner dimensions (W × D × H) mfr 1000 × 5400 × 1400 mm
Outer dimensions (W × D × H) mfr 1670 × 6190 × 2520 mm
Dimensions, Weight & Mechanical Design
Weight 10300 kg
Operating Conditions, Environment & Protection
Max temperature 1340 °C

Description

Construction and series positioning

Electrical and thermal behaviour

Control and documentation

Integration & Operating Notes

Process Limits
Do not exceed 1340 °C at the workload

The maximum temperature of 1340 °C is the ceiling for this model; operating above it risks wire-element and lining damage. Because no model-specific curves were supplied, permissible heating rates and load-dependent limits must be taken from the furnace manual before the first firing.

Factory Specification Sheet
Electrical
Confirm connected load before sizing the supply

The furnace is a 3-phase unit, but the matched heating-power figure (370 W) is inconsistent with a 7500-litre, 1340 °C chamber and cannot be used for cable or breaker sizing. Obtain the connected load and full-load current from the nameplate or order-specific circuit diagram.

Factory Specification Sheet
Mounting
Foundation must carry 10300 kg plus the loaded bogie

The furnace alone weighs 10300 kg and occupies an outer footprint of 1670 × 6190 mm. The floor and bogie rail system must be designed for the furnace mass plus the weight of the charge and the bogie, and the 2520-mm outer height must be checked against hall clearance and crane access.

Factory Specification Sheet
Control & I/O
Controller functions are documented only generically

The attached controller document describes the 500-series controllers and MyNabertherm app, including process-data storage and AMS2750F instrumentation types, but gives no W 7500/H-specific parameters. Program setup, thermocouple type and recorder options must be confirmed against the order-specific control documentation.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the W 7500/H rather than the W 5000/H or W 1500?

Choose the W 7500/H when the load requires the 5400-mm chamber depth and the 7500-litre volume at up to 1340 °C. The W 5000/H and W 1500 offer shorter chambers; select them when the workload fits their smaller depths and the larger footprint and 10300-kg mass of the W 7500/H are not justified.

What must be verified before connecting the furnace to the plant electrical system?

The unit is 3-phase, but the listed 370-W heating power is inconsistent with a 7500-litre, 1340 °C furnace and must not be used for design. Obtain the connected load, full-load current and protective-device ratings from the nameplate or order-specific circuit diagram before sizing cables and switchgear.

What site conditions are required for installing the W 7500/H?

Plan for a foundation and bogie rail system that carry the 10300-kg furnace plus the loaded bogie, within an outer footprint of 1670 × 6190 mm and an outer height of 2520 mm. Confirm hall clearance and crane or charging access along the 5400-mm chamber depth before installation.

Which maintenance and accessory information is available for this model?

The attached documents contain no W 7500/H-specific maintenance schedule, service intervals or accessory list; the controller digest covers only generic 500-series functions. Maintenance intervals, spare wire elements, thermocouples and charging accessories must be requested with the order-specific manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF