Nabertherm W 1500/14
Nabertherm W 1500/14 — Furnace Solutions 1400 Degc.
The W 1500/14 is a bogie hearth furnace with a 1500 l chamber (900 × 1900 × 900 mm) and wire heating to 1400 °C, built for loads up to 3500 kg. It is the mid-size 1400 °C modification in the W series, positioned between the W 1500 and W 5000 variants for batch heat treatment on a rail-mounted hearth.
Nabertherm Bogie Hearth Furnaces with Wire Heating up to 1400 °C | Nabertherm Series — Model Comparison & Selection
Full specifications
| Chamber volume | 1500 l |
| Electrical connection | 3-phase |
| Heating power | 110 watt |
| Inner dimensions (W × D × H) mfr | 900 × 1900 × 900 mm |
| Outer dimensions (W × D × H) mfr | 1570 × 2690 × 2020 mm |
| Weight | 3500 kg |
| Max temperature | 1400 °C |
Description
Construction and series positioning
- Bogie hearth architecture: the load sits on a rail-guided hearth that is withdrawn for loading and returned into the fixed heating chamber; the 1500 l workspace measures 900 mm wide × 1900 mm deep × 900 mm high.
- Outer envelope 1570 × 2690 × 2020 mm and 3500 kg machine weight define the civil and handling requirements; the hearth load path and door mechanism are integral to the furnace, not separate ancillaries.
- Within the W 1400 °C wire-heated series, this is the 1500-litre size; siblings W 1500, W 5000, W 5000/H and W 7500 cover smaller and larger chamber volumes, so the W 1500/14 is selected when the batch fits a 900 × 1900 × 900 mm envelope and the 3500 kg class is acceptable.
Thermal behaviour
- Maximum operating temperature is 1400 °C with wire heating elements; the 110 W heating power figure in the matched specs is not consistent with a 1500 l furnace at 1400 °C and is therefore not used for sizing or utility planning here.
- No digitized heating or cooling curves were supplied for this model, so ramp rates and uniformity cannot be stated; process design must rely on the controller documentation and on-site commissioning measurements.
Control and operation
- The furnace is a 3-phase electrical load; final connection data (voltage, current, protection) must come from the nameplate and wiring diagram, as the matched specs do not carry a voltage value.
- Nabertherm controller series 500 and the MyNabertherm app are the documented control platform for process data storage and temperature-uniformity instrumentation; recorder and controller options are ordered separately from the furnace base.
- The attached document digests do not contain model-specific installation or operating instructions for the W 1500/14; the furnace manual must be obtained before commissioning.
Integration & Operating Notes
Nabertherm controller series 500 and the MyNabertherm app provide process-data storage and temperature-uniformity instrumentation, and recorder/controller options are documented separately. Specify the controller, recorder and any AMS2750F instrumentation type at order time; they are not defined by the furnace model code alone.
The supplied document digests cover controllers, fiber-optics glass furnaces, foundry furnaces and dental furnaces, none of which are this model. Maintenance intervals for wire-heating elements, hearth drive and door seals, and the list of consumables and accessories not included in base delivery, must be taken from the W 1500/14 instruction manual and spare-parts list.
Selection & Integration Q&A
Pick the W 1500/14 when the batch fits a 900 × 1900 × 900 mm chamber and the 3500 kg furnace class is acceptable at 1400 °C. The W 1500 is the smaller chamber; the W 5000 and W 7500 are larger, so move up only if the workload exceeds the 1500 l envelope.
The specs give only '3-phase' with no voltage or current, and the 110 W heating-power entry is inconsistent with this size, so do not size from it. Take voltage, full-load current and breaker rating from the nameplate and wiring diagram, and provide a lockable isolator near the furnace.
Controller series 500, MyNabertherm app connectivity, recorders and AMS2750F instrumentation are separate selections, and the supplied digests contain no W 1500/14 manual, spare-parts list or accessory schedule. Obtain the model manual and order controller, recorder and consumables explicitly.