Shimadzu Aggregates Sizer
Shimadzu Aggregates Sizer — Particle size analyzers.
The Aggregates Sizer is a laser diffraction particle size analyzer using a violet laser and Wing sensor II with 78 concentric elements, capturing forward-scattered light up to 60°. It measures 100 nm to 10 µm at concentrations from 0.1 to 1000 ppm, with a minimum 30 s interval, serving aggregation analysis in biopharmaceuticals. The standard unit is distinguished from the TC variant by lacking temperature control.
Direct drop-in replacements
Full specifications
| Detector types | Wing sensor II, 78 concentric sensor elements |
| Forward scatter angle | up to 60 ° |
| Measurement range | 100 nm to 10 µm |
| Measurement range (SALD-7500nano) mfr | 0.007 to 800 μm (SALD-7500nano) |
| Measurement range (SALD-2300) mfr | 0.017 to 2500 μm (SALD-2300) |
| Measurement range (SALD-201V) mfr | 0.25 to 350 μm (SALD-201V) |
| Wavelength (SALD-7500nano) mfr | 405 nm (SALD-7500nano) |
| Wavelength (SALD-2300) mfr | 680 nm (SALD-2300) |
| Wavelength (SALD-201V) mfr | 670 nm (SALD-201V) |
| Detector elements (SALD-7500nano) mfr | 84 elements (SALD-7500nano) |
| Detector elements (SALD-2300) mfr | 84 elements (SALD-2300) |
| Detector elements (SALD-201V) mfr | 54 elements (SALD-201V) |
| Sampler (circulation type) (SALD-7500nano) mfr | available (SALD-7500nano) |
| Sampler (circulation type) (SALD-2300) mfr | available (SALD-2300) |
| Sampler (circulation type) (SALD-201V) mfr | available (SALD-201V) |
| Wet measurement batch cell (SALD-7500nano) mfr | available (SALD-7500nano) |
| Wet measurement batch cell (SALD-2300) mfr | available (SALD-2300) |
| Wet measurement batch cell (SALD-201V) mfr | available (SALD-201V) |
| High-concentration sample measurement (SALD-7500nano) mfr | available (SALD-7500nano) |
| High-concentration sample measurement (SALD-2300) mfr | available (SALD-2300) |
| High-concentration sample measurement (SALD-201V) mfr | available (SALD-201V) |
| Dispersion bath capacity (SALD-MS75) mfr | 100 to 300 cm3 (SALD-MS75) |
| Dispersion bath capacity (SALD-MS23) mfr | 100 to 300 cm3 (SALD-MS23) |
| Max. pump flow rate (SALD-MS75) mfr | 2000 cm3/min (SALD-MS75) |
| Max. pump flow rate (SALD-MS23) mfr | 2000 cm3/min (SALD-MS23) |
| Batch cell capacity (SALD-BC23) mfr | 12 cm3 (SALD-BC23) |
| Batch cell capacity (SALD-BC75) mfr | 5 cm3 (SALD-BC75) |
| Particle size divisions (SALD Series software) mfr | Fixed 51 or 101 divisions (SALD Series software) |
| Measurement principle mfr | Laser diffraction method by violet laser |
| Concentration range mfr | 0.1 ppm to 1000 ppm ppm |
| Minimum measurement interval mfr | 30 seconds |
| Micro cell sample amount mfr | 0.125 mL |
| Batch cell sample amount mfr | 5 mL |
| Repeatability CV (PSL 1 μm, 0.5–5 ppm) mfr | less than 3 % (PSL 1 μm, 0.5–5 ppm) |
| Length | 680 or more mm |
| Width | Approx. 400 mm |
| Required power supply mfr | AC100V, 13A, 50/60 Hz |
Description
Construction and positioning
- The Aggregates Sizer is built around a violet laser diffraction engine with Wing sensor II, a 78-element concentric detector capturing forward-scattered light up to 60°.
- It is a dedicated aggregation analysis system for biopharmaceuticals, not a general-purpose SALD-series size analyzer; the SALD-7500nano, SALD-2300 and SALD-201V cover broader ranges (0.007–800 µm, 0.017–2500 µm, 0.25–350 µm respectively) with 84/84/54 elements.
- Two configurations exist: the standard unit and the Aggregates Sizer TC with temperature control; the standard unit described here has no temperature-control function.
- Sample handling supports a micro cell (0.125 mL) and a batch cell (5 mL), allowing small-volume and larger batch measurement.
Behavior and measurement modes
- The measurement range is 100 nm to 10 µm, with a concentration range of 0.1 ppm to 1000 ppm; the minimum measurement interval is 30 s.
- Particle size divisions in the SALD Series software are fixed at 51 or 101 divisions.
- No digitized curve points are available for this model, so load-dependent behavior cannot be characterized from the supplied facts.
Installation, connection and operation
- The document digests provide no sections or actionable engineering facts on installation, electrical connection, control interfaces or operation; these must be taken from the full instruction manual.
- An optional FDA 21 CFR Part 11 compliant software package is available for regulated environments.
- The unit is part of the SALD Series ecosystem, sharing software conventions (51/101 divisions) with the SALD analyzers.
Integration & Operating Notes
Measurements outside the stated concentration range of 0.1 ppm to 1000 ppm are not supported by the verified specification; dilution or concentration of the biopharmaceutical sample must be planned before analysis to stay inside this window.
The micro cell requires 0.125 mL and the batch cell 5 mL; the chosen configuration determines the minimum sample volume that must be recovered, which is critical when aggregating biopharmaceutical material is scarce.
An FDA 21 CFR Part 11 compliant software package is listed as optional; laboratories requiring audit trails and electronic records must order it separately and validate it as part of the system.
The standard Aggregates Sizer has no temperature-control function; samples sensitive to temperature must be run on the Aggregates Sizer TC variant or handled with external temperature management, since the standard unit cannot regulate sample temperature.
Selection & Integration Q&A
Pick the Aggregates Sizer for biopharmaceutical aggregation analysis in the 100 nm–10 µm range at 0.1–1000 ppm. The SALD-7500nano covers 0.007–800 µm and the SALD-2300 0.017–2500 µm for broader industrial sizing; choose those when the range extends beyond 10 µm.
The base delivery does not include cells; specify the micro cell (0.125 mL) or batch cell (5 mL) according to sample volume. For regulated labs, add the optional FDA 21 CFR Part 11 software. Temperature-sensitive work requires the TC variant instead.
The supplied document digests contain no sections or actionable facts on mounting, environment or duty cycle; these limits must be taken from the full instruction manual before installation planning.
Cells (micro 0.125 mL or batch 5 mL) and the optional Part 11 software are not part of the base unit. The digests provide no service intervals or consumable schedules; consult the full manual for maintenance planning.