Shimadzu LC-MS TQ RX Series
Shimadzu LC-MS TQ RX Series — Mass spectrometers.
The Shimadzu LC-MS TQ RX Series is a triple quadrupole LC-MS/MS platform available in three configurations (LCMS-8060RX, LCMS-8050RX, LCMS-8045RX) with CoreSpray ion source. It delivers high sensitivity for targeted quantitation in complex matrices. The series is positioned for routine and high-throughput bioanalysis, environmental, and food safety testing where reliable trace-level detection is required.
Direct drop-in replacements
Full specifications
Description
Construction and positioning
The LC-MS TQ RX Series is a triple quadrupole mass spectrometer platform offered in three models: LCMS-8060RX, LCMS-8050RX, and LCMS-8045RX. All share the CoreSpray ion source, which is designed for robust ionization and high sensitivity. The series is positioned as a high-sensitivity solution for quantitative LC-MS/MS applications, with the three variants likely differing in sensitivity, scan speed, or hardware configuration to address different throughput and performance needs. ### Behavior under load and media
As a triple quadrupole instrument, the RX Series operates in MRM (multiple reaction monitoring) mode for targeted quantitation, with high sensitivity enabling detection of trace analytes in complex matrices. The CoreSpray ion source contributes to stable ionization across a range of flow rates and mobile phase compositions. No digitized curve points or detailed performance specifications were provided, so specific sensitivity, resolution, or mass range figures cannot be stated. Power consumption is noted as 31% (likely relative to a reference), but the context is unclear.
Integration & Operating Notes
The provided specification lists power consumption as '31 %', which is ambiguous without a reference value. Engineers must obtain the absolute power requirement (kVA) from the site planning guide to ensure adequate electrical supply and cooling capacity.
Selection & Integration Q&A
The RX Series uses the CoreSpray ion source, which is compatible with standard LC flow rates. Ensure the LC system can deliver flow rates within the source's operating range (typically 0.1–2 mL/min) and that the mobile phase is compatible with ESI. Consult the installation manual for specific connection details.
The instrument requires a stable laboratory environment with controlled temperature (typically 15–30°C) and humidity (40–70% non-condensing). Avoid direct sunlight and vibration. Duty cycle depends on the application; continuous operation is possible with proper maintenance. Refer to the site planning guide for exact limits.
Routine maintenance includes cleaning the ion source and checking the vacuum system. Consumables such as ESI needles, capillary, and calibration solutions are typically not included. A nitrogen generator or gas supply is required for the ion source. Refer to the manual for detailed schedules and part numbers.