Shimadzu Maldimini 1
Shimadzu Maldimini 1 — Mass spectrometers.
The Maldmini 1 is a benchtop MALDI digital ion trap mass spectrometer from Shimadzu, combining a MALDI ion source with a digital ion trap (DIT) detector for wide mass range analysis. It is distinguished within its class by sub-μL sample sensitivity and a compact, benchtop configuration. Its primary purpose is rapid, sensitive mass analysis of solid or dried-droplet samples in laboratory settings.
Direct drop-in replacements
Full specifications
| Type | MALDI Digital Ion Trap Mass Spectrometer (MALDImini-1) |
| Detector types | Digital Ion Trap (DIT) (MALDImini-1) |
| Ion source | MALDI (MALDImini-1) |
| Scan speed (MS measurement conditions) mfr | 4000 Da/s (MS measurement conditions) |
| Sensitivity (sample volume, MS/MS and MS3 default) mfr | 50 pmol/spot (sample volume, MS/MS and MS3 default) |
| Sample volume mfr | sub-μL (MALDImini-1) |
| Height | 268 mm (MALDImini-1) |
| Length | 420 mm (MALDImini-1) |
| Width | 385 mm (MALDImini-1) |
| Mass range (MS measurement conditions) mfr | 650-5000 m/z (MS measurement conditions) |
| Footprint (MALDImini-1, reduced to size of a piece of paper) mfr | 420 x 385 mm (MALDImini-1, reduced to size of a piece of paper) |
Description
Construction and Architecture
- The Maldmini 1 integrates a MALDI ion source with a digital ion trap (DIT) mass analyzer in a single benchtop enclosure. - The DIT detector provides digital control of ion trapping and ejection, enabling wide mass range operation. - As a benchtop unit, it is designed for installation on a standard laboratory bench, with no floor-standing infrastructure required. ### Behavior and Performance
- The system is specified for a wide mass range and sub-μL sample sensitivity, making it suitable for analyzing limited sample volumes. - MALDI ionization is performed directly from a sample spot, typically requiring co-crystallization with a matrix. - No digitized curve points or detailed performance curves are available in the provided facts; refer to the manufacturer's specifications for exact sensitivity and mass accuracy figures. ### Installation and Operation
- No PDF digests or manual excerpts were provided, so installation, connection, and control specifics cannot be detailed here. - The instrument is intended for laboratory use; typical installations require a suitable vacuum system (integral to the mass spectrometer) and a PC for control and data acquisition, though these are not confirmed in the facts.
Integration & Operating Notes
The system is specified for sub-μL sample sensitivity, meaning that sample preparation should aim for volumes below 1 μL. Exceeding this may not be harmful but could affect sensitivity and reproducibility. Always follow validated MALDI sample preparation protocols.
Selection & Integration Q&A
Choose the Maldmini 1 when you need a benchtop MALDI digital ion trap with wide mass range and sub-μL sensitivity for compact lab spaces. For higher resolution or tandem MS capabilities, consider other Shimadzu models such as the MALDI-8000 series, but verify availability and specifications.
The provided facts do not specify network or data system requirements. Typically, mass spectrometers require a dedicated PC with acquisition software and may support Ethernet or USB connections. Consult the Maldmini 1 manual for exact interface specifications and compatibility with laboratory information systems.
The base delivery typically includes the instrument and basic accessories, but consumables such as MALDI matrix, calibration standards, and sample plates are not included. Maintenance items like ion source cleaning kits and vacuum pump oil should be ordered separately. A detailed schedule is in the service manual.