Operating Instructions — vacuum pump (BA 891-EN, ed. 1.0 08.04.2024, EN)
Technical Reference Summary
Covered Models & Document Scope
Covers the contact-free running claw vacuum pumps C-VLU 62 and C-VLU 122 in standard version (CD) and XD version with corrosion-protective coating. Document BA 891-EN, edition 1.0, 08.04.2024.
Section-by-Section Technical Breakdown
Describes the C-VLU 62/122 as double-shaft rotary piston (claw) vacuum pumps with contact-free, dry-running rotors synchronised by an oil-lubricated gear pair. The compression chamber is separated from the gearbox by special seals; an integral non-return valve prevents back-ventilation of the evacuated system after stop. Cooling is by a drum fan drawing fresh air between compressor and insulation hood.
- Vacuum connection A, exhaust air connection B with exhaust silencer B1
- Condensate drain B2 only on XD model
- Inlet flange D with non-return valve
- Oil filling point H, oil sight glass I, oil discharge point with magnet K
- Hot surfaces > 70 °C marked Q
- Data plate N and motor data plate P1
Defines continuous operation between 700 mbar (abs.) and an inlet pressure of 40 mbar (abs.). Suction capacity with unrestricted suction is 65 m³/h for C-VLU 62 and 120 m³/h for C-VLU 122 at 50 Hz. The XD design is suitable for water-damp gases (water vapour).
- Continuous operation range: 700 mbar (abs.) down to 40 mbar (abs.) inlet pressure
- Suction capacity 65 m³/h (C-VLU 62) / 120 m³/h (C-VLU 122) at 50 Hz
- XD version with corrosion-protective coating for water-damp gases
- Frequent switching (~10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits
- Outdoor installation requires protection from environmental influences (e.g. protective roof)
- Minimum permissible end pressure is specified on the rating plate
The intake filter protects the machine from dust and other solids in the process gas and is available as an option with a paper filter or a polyester filter.
- Intake filter available with paper filter or polyester filter
- Optional accessory available on request from Gardner Denver
Specifies installation conditions: free access from all sides, unobstructed ventilation grids, no external vibrations, no intake of hot exhaust air from other machines, and at least 50 cm space around the machine for maintenance. The machine must be set up horizontally with a maximum inclination of 8° in all directions and secured against tipping.
- Maximum inclination 8° in all directions
- Minimum 50 cm free space around machine for maintenance
- Cooling air inlets/outlets at least 30 cm from adjacent walls
- Ambient temperature min. +5 °C, max. +40 °C
- Output reduction noticeable above 1000 m above sea level
- Integrated non-return valve may not be removed
- Installation on firm base without anchoring possible; flexible buffers recommended on substructure
Covers removal of blind plugs/adhesive film from vacuum and exhaust connections, connection of pipes, and prevention of excessive forces and torques. The exhaust air opening must not be closed or restricted; maximum permissible back pressure is +30 mbar.
- Maximum permissible back pressure: +30 mbar
- Exhaust air opening must not be closed or restricted; no blocking devices
- Prevent liquids from accumulating in the exhaust line
- Only screw in pipes by hand; use flexible connections if necessary
- Compensators recommended to avoid distorting the piping system
- Suction capacity reduced if inlet pipe is too narrow and/or too long
Electrical installation must be carried out by a qualified electrician observing EN 60204. The user provides the main switch; the motor must be safeguarded by a motor protection switch installed by the operating company. Motors comply with DIN EN 60034, protection class IP 55, insulation class F.
- Electrical installation per EN 60204 by qualified electrician
- Main switch provided by user; motor protection switch installed by operating company
- Motors: DIN EN 60034, IP 55, insulation class F
- Permissible voltage deviation ±5 % of nominal value
- Permissible frequency deviation ±2 %
- AC motors >1.7 kVA, three-phase motors >5.2 kVA, or start currents >60 A not designed for direct-on-line start
- Use star-delta starting, soft starter, or frequency converter where required
- Motor protection circuit breakers with delayed switch-off recommended due to temporary excess current at cold start
Start-up requires an installation check covering transport damage, safe horizontal standing, leak-tight pipe connections, tight screw/flange connections, compliant electrical installation, adequate ventilation, oil level, cleanliness, and function of optional accessories. Rotation direction must be checked with a phase sequence indicator; when viewed at the motor blower, it must rotate counter-clockwise.
- Brief start max. two seconds to check rotation direction
- Correct rotation: counter-clockwise when looking at the motor blower
- Keep 1 m distance from outlet and inlet connections during rotation check
- Machine may only be switched on again after it stands still
- Operation only with sufficient cooling air quantity
- Surface temperatures may exceed 70 °C at operating temperature
On XD models, condensate must be discharged regularly from the silencer through the condensate drain. Before shutdown for more than 2 hours or decommissioning, moisture and pollution must be removed by running the pump at 500 mbar (abs.) for at least 15–30 minutes with dry air.
- XD model: regularly discharge condensate from silencer through condensate drain
- Before shutdown >2 hours: run at 500 mbar (abs.) for at least 15–30 minutes with dry air
- Do not discharge condensate manually; allow machine to cool down first
- Wear protective gloves when handling condensate drain
- Purging gas run-after recommended depending on use case
Decommissioning requires draining condensate, running with dry air, switching off and cooling, closing cut-off devices if present, disconnecting power, depressurising slowly, removing pipes/hoses, draining condensate from silencer (XD), and sealing inlet/outlet stubs with adhesive foil. Recommissioning requires checking machine condition and following installation and commissioning procedures.
- Disconnect power and secure against unexpected restart
- Depressurise by opening pipes slowly
- Seal inlet and outlet stubs with adhesive foil after decommissioning
- For recommissioning, check cleanliness and cabling, then follow installation and commissioning chapters
Covers maintenance table, preparation of maintenance works, cleaning the vacuum pump, lubricating oil check/refill and oil change, air filter (mesh filter, filter silencer, intake filter accessory), motor and coupling, repair/service, and spare parts. Maintenance must be performed only by qualified personnel with the machine disconnected and secured.
- Maintenance table defines intervals (chapter 7.2)
- Oil level checked at oil sight glass; refill as necessary
- Oil change procedure per chapter 7.5.2
- Air filter includes mesh filter and filter silencer; intake filter is an accessory
- Motor and coupling maintenance per chapter 7.7
- Spare parts per chapter 7.9
Technical data chapter references data sheet D 891 for technical data and characteristic curves. Data plate example shows C-VLU 122 CD values: final pressure 40.00/40.00 mbar (abs), pumping capacity 120.0/144.0 m³/h, motor output 2.70/3.00 kW, speed 2897/3495 /min at 50/60 Hz.
- Data plate example: C-VLU 122 CD, 40.00/40.00 mbar (abs), 120.0/144.0 m³/h, 2.70/3.00 kW, 2897/3495 /min
- Operating mode S1 100%
- Technical data and characteristic curves in data sheet D 891
- Noise emission per EN ISO 3744, sound pressure level dB(A)
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Continuous operation permitted between 700 mbar (abs.) and an inlet pressure of 40 mbar (abs.). p.16 ↗ | Select pump only for applications whose continuous inlet pressure stays within this range; operation outside requires manufacturer consultation. | C-VLU 62 and C-VLU 122 |
| Suction capacity with unrestricted suction is 65 m³/h (C-VLU 62) or 120 m³/h (C-VLU 122) at 50 Hz. p.16 ↗ | Use these values for initial sizing; refer to data sheet D 891 for capacity dependence on suction pressure. | C-VLU 62 / C-VLU 122 |
| Maximum permissible back pressure is +30 mbar. p.8 ↗ | Exhaust lines must be sized and routed to keep back pressure below +30 mbar; higher process back pressures require manufacturer contact. | Whole series |
| Ambient and inlet temperature must be between 5 °C and 40 °C. p.8 ↗ | Install in a location with adequate ventilation and no hot exhaust air intake; temperatures outside this range require manufacturer consultation. | Whole series |
| Maximum inclination during installation is 8° in all directions; machine must be set up horizontally. p.17 ↗ | Mount on a plane, even floor and secure against tipping; non-horizontal installation is not permitted. | Whole series |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.17 ↗ | Maintain clearance to prevent recirculation of heated cooling air and overheating. | Whole series |
| Provide at least 50 cm space around the machine for maintenance works. p.17 ↗ | Layout installation to allow access to oil filling point, oil sight glass, and oil drain. | Whole series |
| Permissible voltage deviation is ±5 % of nominal value and frequency deviation ±2 %. p.19 ↗ | Verify mains quality at installation location against motor data plate before connection. | Whole series |
| Motors with AC apparent output >1.7 kVA, three-phase motors >5.2 kVA, or start currents >60 A are not designed for direct-on-line start. p.19 ↗ | Use star-delta starting, soft starter, or frequency converter for such motors to limit starting torque and mechanical load. | Whole series |
| Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.19 ↗ | Suitable for dusty/damp industrial environments within IP55 limits; electrical installation per EN 60204. | Whole series |
| Correct direction of rotation is counter-clockwise when looking at the motor blower; check with a phase sequence indicator. p.21 ↗ | Brief start max. two seconds to verify rotation; wrong rotation can damage the machine and cause injury. | Whole series |
| Before shutdown for more than 2 hours, run the pump at 500 mbar (abs.) for at least 15–30 minutes with dry air. p.21 ↗ | Prevents condensate and impurities from adhering to rotors and casing and blocking restart. | Whole series; especially XD |
| Storage temperature range is -20 °C to +70 °C; relative air humidity max. 80 %; storage not to exceed 6 months. p.13 ↗ | Store dust-free, dry, vibration-free, protected from sun radiation, with openings sealed air-tight. | Whole series |
| Output reduction is noticeable when installed at more than 1000 m above sea level. p.18 ↗ | Contact manufacturer for installations above 1000 m elevation. | Whole series |
| Data plate example C-VLU 122 CD: final pressure 40.00/40.00 mbar (abs), pumping capacity 120.0/144.0 m³/h, motor output 2.70/3.00 kW, speed 2897/3495 /min at 50/60 Hz, operating mode S1 100%. p.15 ↗ | Use data plate values for verification of delivered unit against order; minimum permissible end pressure is specified on the rating plate. | C-VLU 122 CD |
| XD model is suitable for conveying water-damp gases (water vapour); standard model is for dry gases only. p.8 ↗ | Select XD variant when process gas contains moisture; standard model must not convey water vapour. | XD variant vs. standard |
| Frequent switching at regular intervals of approx. 10 times per hour or higher ambient/inlet temperatures may exceed motor winding and bearing temperature limits. p.16 ↗ | Contact manufacturer for such duty; may require alternative motor or cooling measures. | Whole series |
| The vacuum pump does not have its own Emergency Stop or Emergency Off. p.11 ↗ | Operator must integrate the pump into the plant protection concept to provide Emergency Stop/Off. | Whole series |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.31 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.31 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent turn-off delay that considers the short excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 102 or IEC 60947-4-1) | |
| Suction capacity is insufficient p.31 ↗ | Air filter is polluted | Clean/replace air filter | Chapter 7.6 / Chapter 7.9 |
| Suction capacity is insufficient p.31 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Suction capacity is insufficient p.31 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. vacuum) is not reached p.31 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and check for tight fit | Chapter 5.3 |
| Final pressure (max. vacuum) is not reached p.31 ↗ | Air filter is polluted | Clean/replace air filter | Chapter 7.6 / Chapter 7.9 |
| Machine gets too hot p.31 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.31 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.31 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| The machine makes a strange noise p.31 ↗ | Deposits on the rotary piston | Clean the working space and the rotary piston | Elmo Rietschle Service |