Agilent Technologies 4200 FlexScan

Agilent Technologies 4200 FlexScan — Molecular spectroscopy.

The 4200 FlexScan is a handheld FTIR spectrometer whose optical head (3 lb) is separated from the battery/electronics pack (4 lb) by a cable, enabling access to samples where a single-body analyzer cannot reach. It is calibrated for IR absorbance from 0.05 to 1 absorbance units using 0.06 mil calibration thicknesses, with a primary band at 1610 cm⁻¹ and alternatives at 1510 and 1285 cm⁻¹. It serves field and onsite molecular spectroscopy, including art conservation and diffuse-reflectance geolibrary work.

Agilent Technologies FTIR Compact Portable Systems Series — Model Comparison & Selection

Model Wavelength rangeWeight, kgAnalysis time, minDimensions, mmPower supplyProtection rating
4200 FlexScan Current 4000...650—————
4500 Portable FTIR Spectrometer, Rugged Non-Lab Analyzer —3.6less than two minutes203battery or mains54
Compact FTIR Spectrometer, At-side FTIR Analyzer —3.6less than two minutes203battery or mains54
Handheld FTIR, Mobile Nondestructive Testing —2.27————

Full specifications

Core Performance & Functional Specifications
Wavelength range 4000...650
Laser Low-powered solid state
Spectral resolution 4 dimensionless
Calibration band center mfr 1610
Absorbance of thinnest sample mfr 0.07 units
Absorbance of thickest sample mfr 0.7 units
Linear range of IR absorbance mfr 0.05...1 units
Alternative stronger band mfr 1510
Alternative weaker band mfr 1285
Calibration thicknesses mfr 0.06 mils
Interferometer geometry mfr High-throughput Michelson interferometer with fi
Source mfr Wire-wound element element
Detector mfr 1.3 dTGS
Optical compartment dimensions mfr 5.5 in
Electrical compartment dimensions mfr 7.5 in
Handheld PC processor mfr 520
Handheld PC memory mfr 64 RAM
Handheld PC hard drive mfr 128 flash
Stability specification @ 3000 cm-1 mfr 2
Stability specification @ 1000 cm-1 mfr 1
non-contact standoff distance mfr 5 mm
protein band region mfr -1...1700
number of co-added scans mfr 128 scans
collection and processing time mfr 1 minute
ATR mfr 2500
External reflectance mfr 1500
Grazing angle mfr 1500
System OFF mfr Red Red
System startup mfr Red / green green
System ON mfr Green Green
Firmware update mfr Red / green green
ATR diamond diameter mfr 2 mm
ATR active area mfr 200 μm
Sample press force mfr 15 force
Dimensions, Weight & Mechanical Design
Optical head weight mfr 3 pound
Optical compartment weight mfr 3.2 lb
Electrical compartment weight mfr 2.5 lb
Cord length mfr 6.5 coiled
Cord weight mfr 2.1 lb
ATR depth of penetration mfr 2 micron
Electrical, Power & Drive Specifications
Battery and electronics pack weight mfr 4 pound
Battery mfr 10.8 mAh
Laser frequency calibration specification mfr 1
Low battery mfr Green Green
Critically low battery mfr Red Red
Dead battery mfr No LED illumination illumination
Battery run time mfr 4 hours
Battery run time per battery mfr 4 hours
Interfaces, Connections & Control
Sample interface mfr External reflectance , grazing angle , diffuse r
Operating Conditions, Environment & Protection
Storage temperature 30...60 °F
Humidity mfr 90 condensing
Signal-to-noise specification @ 2500 cm-1 mfr 1500
Signal-to-noise specification @ 1000 cm-1 mfr 2800
Operating humidity mfr 95
Standards, Safety & General Data
Standard beamsplitter mfr Zinc selenide selenide

Description

Construction and series positioning

Optical behavior and calibration

Installation, connection and operation

Integration & Operating Notes

Process Limits
Keep sample absorbance within the 0.05–1 linear range

The calibration is stated for IR absorbance from 0.05 to 1, with the thinnest calibration sample at 0.07 and the thickest at 0.7. Samples outside this range fall beyond the characterized linear region, so thickness or path length must be adjusted before quantitative use.

Factory Specification Sheet
Mounting
Optical head and electronics pack are separate masses

The optical head weighs 3 lb and the battery/electronics pack 4 lb, joined by a cable. The head must be supported or positioned independently of the pack, so the mounting or handling arrangement has to account for two separate masses rather than one balanced body.

Application Note 5990-7795EN
Control & I/O
Cable-linked architecture defines the working envelope

Because the optics and electronics are separated by a cable, the reachable sample area is bounded by that link. The verified documents give no cable length, connector type or control interface, so these must be confirmed against the instrument manual before integration.

Application Note 5990-7795EN
Maintenance
No service intervals are documented in the verified material

The attached application notes contain no maintenance schedule, error codes or consumable lists. Calibration references at 1610, 1510 and 1285 cm⁻¹ and the 0.06 mil calibration thicknesses are the only reference standards given; service planning must rely on the instrument manual, not these notes.

Application Notes 5990-8739, 5990-7794EN, 5990-7795EN

Selection & Integration Q&A

When should I choose the 4200 FlexScan rather than the 4100 ExoScan or 4300 Handheld FTIR?

Pick the 4200 when the sample is hard to reach with a single-body analyzer: its 3 lb optical head is separated from the 4 lb electronics pack by a cable. The 4100 ExoScan and 4300 are described as handheld units without that split, so they suit direct-access measurements.

What sampling interface and reference data are needed alongside the 4200 for diffuse reflectance work?

The 4200 FlexScan is documented with a diffuse reflectance sampling interface and the diffuse reflectance geolibrary. Plan for that interface as an adjacent part; the verified notes do not list it as included in base delivery, so confirm the configuration with the supplier.

What absorbance and thickness limits constrain field measurements with this model?

Quantitative use is bounded by the 0.05–1 IR absorbance linear range, with calibration samples from 0.07 (thinnest) to 0.7 (thickest) absorbance at 0.06 mil calibration thicknesses. Samples outside that window need thickness or path-length adjustment before measurement.

What is supplied for calibration and service, and what must be obtained separately?

The verified material lists calibration band centers at 1610, 1510 and 1285 cm⁻¹ and 0.06 mil calibration thicknesses, but no maintenance schedule, cables, accessories or consumables are documented as included. Those items and any service intervals must be confirmed from the instrument manual or supplier.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Handheld FTIR Analysis for the Agilent 4100 ExoScan and 4200 FlexScan
Brochure ·2,6 МБ ·7 pp.
View PDF
PDF
At Site Rock and Mineral Measurement: Diffuse Reflectance Geolibrary
Brochure ·1,1 МБ ·4 pp.
View PDF
PDF
Agilent 4200 FlexScan FTIR Handheld Spectrometer User's Guide
Manual ·42 pp.
View PDF