Agilent Technologies Analytical HPLC and UHPLC Systems
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Analytical HPLC and UHPLC Systems

Agilent Technologies Analytical HPLC and UHPLC Systems — Liquid chromatography.

The Agilent InfinityLab analytical HPLC/UHPLC system is a modular liquid chromatography platform built around a 4.6 mm internal-diameter column format and a typical flow rate of 1 mL/min. It is the standard analytical-scale configuration of the InfinityLab series, distinguished from the 2D-LC, bio-inert, GPC/SEC and application-specific siblings by its conventional analytical column dimension. It serves as the primary separation and quantitation front end for routine small-molecule analysis in a chromatography workflow.

Agilent Technologies HPLC Systems Series — Model Comparison & Selection

Model Max pressure, megapascalCarryover, %Column inner diameter, mmMaximum pressure, barSample capacityTypical flow rate, mL/min
Analytical HPLC and UHPLC Systems Current —9×10⁻⁴4.6130061441
2D-LC System 1309×10⁻⁴4.6130061441
GPC/SEC Systems, Macromolecular Analysis and Solution —9×10⁻⁴4.6130061441
Preparative HPLC Systems, InfinityLab LC Purification Solutions —9×10⁻⁴4.6130061441

Full specifications

Core Performance & Functional Specifications
Carryover 9 ppm
Maximum pressure 1300 bar
Sample Capacity 6144 samples
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm

Description

Construction and series positioning

Behavior and performance envelope

Installation, control and operation

Integration & Operating Notes

Process Limits
Carryover of 9 ppm constrains low-level sequence design

Residual carryover of 9 ppm means a high-concentration injection can leave a detectable residue in the following run. Sequence high-concentration samples after low-level ones, or insert blank/wash injections, when quantitating near that level.

Factory Specification Sheet
Control & I/O
No model-specific electrical or interface data verified

The verified facts contain no voltage, current, communication-interface or controller specifications for this analytical configuration. Electrical and I/O requirements must be taken from the instrument's own site-preparation and installation documentation before integration.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this analytical HPLC/UHPLC configuration instead of the 2D-LC, Bio or GPC/SEC siblings?

Choose this analytical modification for conventional small-molecule separations on 4.6 mm ID columns at about 1 mL/min. Select the 2D-LC sibling for multidimensional separations, the Bio/Bio-Inert sibling for biological samples, and the GPC/SEC sibling for macromolecular molecular-weight work.

What adjacent system parts must be matched to this configuration?

Columns must be 4.6 mm internal diameter to match the analytical flow regime of about 1 mL/min. No verified data exist for pump pressure rating, detector, autosampler interface or controller, so those must be confirmed from the instrument's own site-preparation documentation.

What mounting and environmental limits apply to this system?

The verified facts contain no ambient temperature, humidity, altitude or bench-loading specifications for this analytical configuration. Installation environment and duty-cycle limits must be taken from the instrument's site-preparation guide; the attached portfolio brochures do not state them.

What maintenance and consumables should be planned beyond base delivery?

No service intervals, spare parts or consumable lists are verified for this model. Plan column and wear-part replacement from the instrument's maintenance manual; the attached brochures cover the 2D-LC, Bio LC and purification portfolios and do not define analytical-system consumables.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 1260 Infinity II Bio-Inert LC System - Span the Spectrum of Bio LC
Brochure ·2,6 МБ ·16 pp.
View PDF