Agilent Technologies Bond Elut HLB | SPE Sorbent
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Bond Elut HLB | SPE Sorbent

Agilent Technologies Bond Elut HLB | SPE Sorbent — Sample preparation with Pumping speed 1.8×10⁻⁵ m³/h.

Bond Elut HLB is a 6 mL, 500 mg polymeric SPE cartridge for extracting sulfonamide drugs from water. It is the HLB modification in the Bond Elut series, distinguished by its hydrophilic-lipophilic balance sorbent. The cartridge serves as the sample preparation front-end for LC/MS/MS quantification, achieving method detection limits of 0.28–1.88 ng/L.

Pumping speed
1.8×10⁻⁵ m³/h

Agilent Technologies Bond Elut Series — Model Comparison & Selection

Model Pumping speed, m³/hSample volume, milliliterDrying gas temperature, °CAverage recovery all compounds, %Cartridge sorbent mass, mgCentrifugation speed, rpm
Bond Elut HLB | SPE Sorbent Current 1.8×10⁻⁵0.0024073.4...118500—
Bond Elut Carbon S & Carbon S/NH2 0.0240.00523099.21501900
Bond Elut Lipid Extraction 3...5—30———
Bond Elut LMS | Large Molecule Size —0.005———2800

Full specifications

Core Performance & Functional Specifications
Pumping speed 0.3 mL/min
Average Recovery (all Compounds) 73.4...118
Cartridge Volume 6 mL
Gas Flow 6 L/min
Reconstitution Volume 1 mL
Rsd (all Compounds) 14 %
Sample volume 2 µL
Sheath Gas Flow 11 L/min
Spe Cartridge Volume 6 mL
Syringe Filter Pore Size 0.2 µm
Syringe filter diameter mfr 15 mm
LC flow rate mfr 0.3 mL/min
Method detection limit range mfr 0.28...1.88 ng/L
Method quantitation limit range mfr 1.12...7.52 ng/L
Linearity (R2) mfr 0.996...0.999
Linearity (R2) mfr 0.996...0.999
Water sample volume mfr 500 mL
EDTA final concentration mfr 0.5 g/L
Sample loading flow rate mfr 5 mL/min
Elution volume per aliquot mfr 4 mL
Dimensions, Weight & Mechanical Design
Cartridge Sorbent Mass 500 mg
Spe Cartridge Sorbent Mass 500 mg
Electrical, Power & Drive Specifications
Capillary Voltage 3500 V
Nozzle Voltage 500 V
Operating Conditions, Environment & Protection
Drying Gas Temperature 40 °C
Gas Temperature 325 °C
Sheath gas heater mfr 350 °C

Description

Construction and Series Positioning

Behavior Under Load and Method Performance

Installation, Connection and Operation

Integration & Operating Notes

Process Limits
Maintain pH and solvent conditions compatible with HLB sorbent

The HLB polymeric sorbent operates across a wide pH range, but the application note specifies conditioning and elution solvents. Deviating from the validated solvent sequence can shift recovery outside the 73.4–102% range and compromise the 0.28–1.88 ng/L MDL.

Application Note 5994-6896EN, SPE Method
Maintenance
Use a fresh cartridge for each extraction; do not reuse

The cartridge is a single-use consumable. Reusing a cartridge after elution risks carryover and variable recovery. The application note describes a single condition-load-wash-elute sequence per cartridge; no regeneration procedure is provided.

Application Note 5994-6896EN, SPE Method
Control & I/O
LC/MS/MS parameters are method-specific, not cartridge properties

Capillary voltage 3500 V, nozzle voltage 500 V, sheath gas 11 L/min at 350 °C, MS gas 6 L/min at 325 °C, and LC flow 0.3 mL/min are detection-method settings from the application note. They must be optimized on the actual instrument and are not supplied by the cartridge.

Application Note 5994-6896EN, LC/MS/MS Conditions

Selection & Integration Q&A

When should I choose Bond Elut HLB over the C18 or ENV siblings for water sample extraction?

Choose HLB for balanced retention of polar and nonpolar analytes such as sulfonamides; C18 is a silica-based reversed phase with limited polar retention, and ENV is a styrene-divinylbenzene polymer. HLB is the validated choice for the 19-sulfonamide method with MDL 0.28–1.88 ng/L.

What sample filtration and injection requirements must be met before LC/MS/MS with this cartridge method?

The method specifies a 0.2 µm syringe filter (15 mm diameter) for sample filtration and a 2 µL injection volume. LC flow is 0.3 mL/min. These are method requirements; the cartridge itself does not include filters or syringes.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Analysis of Sulfonamide Drugs
Brochure ·349,7 КБ ·5 pp.
View PDF