Agilent Technologies Bond Elut Lipid Extraction
Agilent Technologies Bond Elut Lipid Extraction — Sample preparation.
Bond Elut Lipid Extraction is a 1 mL SPE cartridge with EMR—Lipid sorbent for plasma, cell culture and tissue samples. It uses 100 µL plasma and 900 µL crashing solvent (9:1 ratio, 5% MeOH recommended), then wash and elute. It removes lipids before LC-MS or GC-MS analysis of small molecules.
Agilent Technologies Bond Elut Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Sample volume, milliliter | Drying gas temperature, °C | Average recovery all compounds, % | Cartridge sorbent mass, mg | Centrifugation speed, rpm |
|---|---|---|---|---|---|---|
| Bond Elut Lipid Extraction Current | 3...5 | — | 30 | — | — | — |
| Bond Elut Carbon S & Carbon S/NH2 | 0.024 | 0.005 | 230 | 99.2 | 150 | 1900 |
| Bond Elut HLB | SPE Sorbent | 1.8×10⁻⁵ | 0.002 | 40 | 73.4...118 | 500 | — |
| Bond Elut LMS | Large Molecule Size | — | 0.005 | — | — | — | 2800 |
Full specifications
| Pumping speed | 3...5 drop |
| Crashing Solvent Volume | 900 μL |
| Plasma Sample Volume | 100 μL |
| Recommended Flow Rate | 3...5 drop |
| Reconstitution Volume | 100 µL |
| Cartridge format mfr | 1 mL |
| Sorbent chemistry mfr | EMR—Lipid Lipid |
| Sample types mfr | plasma, cell cultures, tissue samples samples |
| Washing solvent mfr | 10...20 % water |
| Elution solvent mfr | 1 % MeOH |
| Recommended elution solvent mfr | DCM/MeOH or chloroform/MeOH v/v v/v |
| Vortex time mfr | 30 seconds |
| Sonicate time on ice mfr | 10 minutes |
| Wash volume mfr | 2 mL |
| Plate format mfr | 96 plate |
| Recommended crashing solvent mfr | 5 % MeOH |
| Crashing solvent to sample ratio mfr | 9 |
| Minimum MeOH content for elution mfr | 50 |
| Collection plate volume mfr | 2 mL |
| Sonicating time mfr | 10 minutes |
| Wash solvent volume mfr | 2 mL |
| Elution volume mfr | 2 mL |
| Crashing solvent composition mfr | 1...5 % MeOH |
| Washing solvent composition mfr | 10...20 % water |
| Elution solvent composition mfr | 1 % MeOH |
| Vortex duration mfr | 30 seconds |
| Sonicate duration on ice mfr | 10 minutes |
| Reconstitution vortex duration mfr | 2 minutes |
| Reconstitution sonicate duration mfr | 10 minutes |
| Crashing solvent/plasma ratio mfr | 9 v/v |
| Minimum aqueous content in sample mixture for loading mfr | 10 |
| Agilent Bond Elut Lipid Extraction, 1 mL cartridge mfr | 100 pk |
| Agilent Bond Elut Lipid Extraction, 96-well plate mfr | 5 plates |
| crashing solvent MeOH content mfr | 1...5 |
| washing solvent water content mfr | 10...20 |
| minimum MeOH in elution solvent mfr | 50 |
| vortex time mfr | 30 seconds |
| sonication time on ice mfr | 10 minutes |
| wash volume mfr | 2 mL |
| elution volume mfr | 2 mL |
| reconstitution sonication time mfr | 10 minutes |
| minimum aqueous content in sample mixture mfr | 10 |
| 96-well plate variant mfr | 96 w |
| Drying Gas Temperature | 30 °C |
| Storage temperature | 20 °C |
Description
Construction and series positioning
- This model is the 1 mL cartridge format of Bond Elut Lipid Extraction; the same sorbent is also offered as a 96-well plate (96-w, 1 plate, part number 5610-2042).
- Sorbent chemistry is EMR—Lipid, a lipid-selective phase; sibling Bond Elut sorbents (Carbon S, ENV, Focus, HLB) are general or class-specific phases, not lipid-specific.
- The cartridge is a single-use device; no electrical, drive or control specifications apply.
Working range and media
- Sample types: plasma, cell cultures and tissue samples.
- Plasma sample volume: 100 µL; crashing solvent volume: 900 µL, a 9:1 solvent-to-sample ratio.
- Crashing solvent: 1–5% MeOH (5% recommended); washing solvent: 10–20% water; wash volume 2 mL.
- Elution: 1 mL; recommended elution solvents are DCM/MeOH or chloroform/MeOH; minimum MeOH content for elution is 50%.
- Sample prep: vortex 30 s, sonicate 10 min on ice.
Operation
- Method sequence per the method guides: protein precipitation (crashing), sample loading, washing and lipid elution.
- The 96-well variant uses a 2 mL collection plate volume; the 1 mL cartridge method is documented in the 1 mL cartridge method guide.
- No curves, certificates or applications data are supplied; performance claims are limited to the method parameters above.
Integration & Operating Notes
The method specifies 1–5% MeOH in the crashing solvent, with 5% recommended, at a 9:1 solvent-to-sample ratio (900 µL to 100 µL plasma). Deviating outside this window changes protein precipitation and lipid binding, so the solvent must be prepared and verified before loading.
Lipid elution requires a minimum MeOH content of 50%; recommended elution solvents are DCM/MeOH or chloroform/MeOH at 1 mL. A lower-MeOH eluent will not quantitatively release retained lipid, so solvent composition must be checked before use.
The documented protocol requires 30 s vortexing followed by 10 min sonication on ice after adding crashing solvent. Skipping or shortening these steps leaves incomplete protein precipitation and can foul the sorbent bed, so they must be scheduled into the batch workflow.
This model is the 1 mL cartridge; the 96-well plate variant (5610-2042) uses a 2 mL collection plate and its own method guide (5994-1690EN). Vacuum manifolds and collection racks must match the chosen format; the two are not interchangeable on the same hardware.
Selection & Integration Q&A
Pick the 1 mL cartridge for low-to-medium sample counts and method development, where individual cartridges are processed on a vacuum manifold. Choose the 96-well plate (5610-2042) for higher-throughput batches; it uses a 2 mL collection plate and the separate 5994-1690EN method.
A vacuum SPE manifold accepting 1 mL cartridges, a 2 mL collection tube or plate position, and prepared solvents: crashing solvent at 1–5% MeOH (5% recommended), 10–20% water wash, and DCM/MeOH or chloroform/MeOH eluent with at least 50% MeOH. Vortex and ice-bath sonicator are also required.
The method fixes 100 µL plasma to 900 µL crashing solvent (9:1), a 2 mL wash and 1 mL elution. Scaling changes the ratio and the minimum 50% MeOH elution condition; revalidate recovery and lipid removal before altering volumes.
The cartridge is supplied as the SPE device only; collection tubes or the 2 mL collection plate, vacuum manifold, vortexer, sonicator and all solvents (MeOH, water, DCM, chloroform) are not part of the delivery and must be sourced separately.