Agilent Technologies Scroll Pumps for Helium Recirculation & Cryogenic Applications
Agilent Technologies Scroll Pumps for Helium Recirculation & Cryogenic Applications — Vacuum technologies with Motor power 0.119 kW, Pumping speed 3.6 m³/h.
The Agilent IDP dry scroll pump is an oil-free, hermetic roughing pump for helium recirculation and cryogenic service. This configuration delivers 60 L/min pumping speed and 3.3 mbar base pressure from a 0.16 HP motor at 100 VAC. It sits in the IDP family alongside the 2.1, 5.4, 20.60 and 26.48 CFM variants, covering small-to-mid laboratory vacuum duties.
Agilent Technologies Idp Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Ultimate pressure, mbar | Pumping speed, m³/h | Base pressure, mbar | Supply frequency, Hz | Operating temperature, °C |
|---|---|---|---|---|---|---|
| Scroll Pumps for Helium Recirculation & Cryogenic Applications Current | 0.119 | — | 3.6 | 3.3 | — | — |
| 20.60 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 26.48 CFM | 0.119 | 3.3 | 3.6 | 3.3 | 50 | — |
| 6.0 CFM | — | — | — | — | — | — |
| IDP-4 | 0.119 | 2.4 | 3.6 | 3.3 | — | 5 |
Full specifications
| Motor power | 0.16 HP |
| Pumping speed | 60 L/min |
| Base Pressure | 3.3 mbar |
| IDP-10 mfr | 3810 |
| IDP-10 with inlet isolation valve mfr | 3810 |
| IDP-7/10 tip seal replacement kit mfr | 3807 |
| Exhaust silencer kit mfr | 110 |
| Purge kit mfr | 3807 |
| Gas ballast kit mfr | 3807 |
| Inlet trap mfr | 25 |
| Vibration isolation kit mfr | 110 VIBISOKIT |
| IDP-35 mfr | 3835 |
| IDP-35 with Gauge mfr | 3835 |
| IDP-35 with Inlet Valve mfr | 3835 |
| IDP-35 with Inlet Valve and Gauge mfr | 3835 |
| Inlet HEPA filter, NW40 mfr | 40 |
| HEPA filter, NW25 mfr | 25 |
| IDP-45 mfr | 3845 |
| IDP-45 with Gauge mfr | 3845 |
| IDP-45 with Inlet Valve mfr | 3845 |
| IDP-45 with Inlet Valve and Gauge mfr | 3845 |
| IDP-15 mfr | 3815 |
| IDP-15 with inlet isolation valve mfr | 3815 |
| IDP-15 tip seal replacement kit mfr | 3815 |
| IDP-3 mfr | Vibration isolation kit kit |
| IDP-4 mfr | Replacement filter element element |
| IDP-7 mfr | Vibration isolation kit kit |
| inlet valve closing time mfr | 20 milliseconds |
| inlet valve opening time after power restore mfr | 10 seconds |
| tip seal replacement duration mfr | half an hour hour |
| IDP-4 maintenance duration mfr | 15...30 minutes |
| integrated Pirani gauge pressure range mfr | -4...1000 mbar |
| VPI valve isolation time mfr | 20 ms |
| Operating voltage mfr | 100 VAC |
| IDP-35/IDP-45 supply frequency mfr | 50 Hz |
Description
Construction and series positioning
- Dry scroll, oil-free architecture with no hydrocarbon backstreaming into the process.
- This model is rated at 60 L/min (≈2.1 CFM) and 3.3 mbar base pressure, placing it at the small-capacity end of the IDP family.
- Sibling models in the same series span 2.1, 5.4, 20.60 and 26.48 CFM; the 20.60 and 26.48 CFM units share the same 0.16 HP motor and 3.3 mbar ultimate pressure, so the choice between them is driven by required throughput, not by achievable vacuum.
Behavior and operating envelope
- Base pressure of 3.3 mbar defines the lower limit of the working range; the pump is intended for rough-to-medium vacuum, not high-vacuum generation.
- Pumping speed of 60 L/min is the nominal figure at the specified operating point; no curve data is available for this configuration, so part-load behavior should be confirmed against the family datasheet.
- The 0.16 HP (≈119 W) motor is consistent across the 20.60 and 26.48 CFM siblings, indicating a common drive platform within the family.
Electrical and control specifics
- Operating voltage for this configuration is 100 VAC. The IDP family also includes 100–120/200–240 VAC motor variants and a 24 VDC drive (IDP-3); the supply must match the nameplate variant ordered.
- No control interface, I/O or communication details are documented for this model in the available digests; integration should rely on the unit's local switch and the facility's own interlock scheme.
Installation and operation
- The available family digest does not contain section-level installation, connection or maintenance procedures for this model; refer to the full instruction manual for mounting orientation, inlet/outlet connections and service intervals.
Integration & Operating Notes
The IDP family is offered with 100–120/200–240 VAC motor variants and a 24 VDC drive on the IDP-3. Applying a supply outside the nameplate rating of the specific unit ordered will damage the motor. Verify the variant on the label before wiring, and do not assume the 100 VAC figure applies to every IDP pump.
The available document digest contains no section-level maintenance schedule, tip-seal replacement interval or error-code table for this model. Obtain the full instruction manual before commissioning to establish preventive-maintenance intervals and spare-parts list; do not extrapolate intervals from other IDP sizes.
No mounting-orientation, clearance or flange data is present in the available digest for this configuration. Confirm baseplate or bench mounting, inlet flange type and exhaust connection from the unit's manual before designing the foreline and exhaust routing.
Selection & Integration Q&A
All three share 0.16 HP and 3.3 mbar base pressure, so the decision is throughput. Pick this 60 L/min unit for small chambers and helium recirculation loops where 2.1 CFM is sufficient; move to the 20.60 or 26.48 CFM variants when pump-down time or gas load demands higher speed at the same ultimate pressure.
The unit is a 100 VAC variant, so the supply must match its nameplate; the family also includes 100–120/200–240 VAC and 24 VDC (IDP-3) drives, which are not interchangeable. Inlet and exhaust fittings are manual-defined, and with a 3.3 mbar base pressure any process needing lower pressure requires an additional high-vacuum stage downstream.
The available family digest gives no mounting orientation, clearance or duty-cycle data for this configuration. Before installation, consult the full instruction manual for allowable tilt, ambient temperature and continuous-operation limits; do not assume the pump may be mounted in any orientation or run continuously without confirmation.
The digest lists no tip-seal kit, inlet filter, exhaust hose or cable as included, and no service interval is documented for this model. Obtain the full manual to establish scroll-tip-seal replacement intervals and the spare-parts list, and budget for foreline fittings and exhaust lines separately from the pump.