Agilent Technologies Preparative HPLC Systems, InfinityLab LC Purification Solutions
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Preparative HPLC Systems, InfinityLab LC Purification Solutions

Agilent Technologies Preparative HPLC Systems, InfinityLab LC Purification Solutions — Liquid chromatography.

The Agilent InfinityLab LC Purification Solutions preparative HPLC platform is a modular benchtop system built around preparative-scale pumps, columns and fraction collection, configured from 1220/1260/1290 Infinity II modules. It is distinguished within the HPLC series by preparative rather than analytical duty, with a stated productivity range in micrograms and a 4.6 mm analytical column inner diameter as the reference scale. It serves purification and fraction-isolation steps upstream of analysis or structure confirmation.

Agilent Technologies HPLC Systems Series — Model Comparison & Selection

Model Max pressure, megapascalCarryover, %Column inner diameter, mmMaximum pressure, barSample capacityTypical flow rate, mL/min
Preparative HPLC Systems, InfinityLab LC Purification Solutions Current —9×10⁻⁴4.6130061441
2D-LC System 1309×10⁻⁴4.6130061441
Analytical HPLC and UHPLC Systems —9×10⁻⁴4.6130061441
GPC/SEC Systems, Macromolecular Analysis and Solution —9×10⁻⁴4.6130061441

Full specifications

Core Performance & Functional Specifications
Carryover 9 ppm
Maximum pressure 1300 bar
Sample Capacity 6144 samples
Typical Flow Rate 1 mL/min
Productivity range mfr Micrograms Micrograms
Dimensions, Weight & Mechanical Design
Column Inner Diameter 4.6 mm

Description

Construction and positioning

Behavior and scale

Installation and operation

Integration & Operating Notes

Control & I/O
Module set defines the control and detector architecture

Because the platform is configured from separate InfinityLab modules (pumps, injector, column compartment, detectors, fraction collector, optional LC/MSD XT), the control interface and signal routing depend on which modules are ordered. Confirm the module list and software before specifying the system, as the supplied document digests contain no connection or control details.

Brochure InfinityLab LC Purification Solutions 5991-9154EN

Selection & Integration Q&A

When should I choose this preparative purification platform instead of the analytical HPLC/UHPLC or 2D-LC siblings?

Choose it when the goal is isolating fractions at microgram-to-preparative scale with a fraction collector and preparative columns. For routine quantification choose the analytical HPLC/UHPLC systems; for multidimensional separation of complex samples choose the 2D-LC System; for biomolecule-inert flow paths choose the Bio HPLC systems.

What adjacent system parts must be specified together with the platform?

The platform is modular: preparative pump, injector, column organizer or compartment, detector, fraction collector and optional LC/MSD XT are separate modules, and preparative columns and supplies are a separate portfolio. Specify the full module list and column hardware together, since the base delivery does not include columns.

What mounting and duty-cycle limits apply to this system?

The verified facts and attached document digests contain no mounting, clearance, environment or duty-cycle data. These must be taken from the installation manual of each InfinityLab module in the delivered configuration; do not assume benchtop clearances from the brochure.

What maintenance and consumables are not included in the base delivery?

Preparative columns and supplies are a separate portfolio item and are not part of the base system. No service intervals or replacement-part schedules are stated in the verified facts; obtain them from the module manuals. The 6144-sample capacity refers to sampler capacity, not a maintenance interval.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 1260 Infinity II Bio-Inert LC System - Span the Spectrum of Bio LC
Brochure ·2,6 МБ ·16 pp.
View PDF