Smart SPME Arrow with 20 mm arrow length, 10 mm fiber length, 30 µm PDMS phase (0.6 µL sorption volume), 23-gauge needle and 1.1 mm outside diameter. This modification is the nonpolar semivolatile configuration within the Smart SPME Arrow series, distinguished from 1.5 mm OD arrows and from 10 mm SPME fibers by its longer arrow body and larger sorption phase volume. It is used for headspace or direct immersion extraction of nonpolar to semivolatile analytes prior to GC or GC-MS analysis.

Agilent Technologies Solid Phase Microextraction Spme Series — Model Comparison & Selection

Model Arrow length, mmFiber length, mmPack quantity, pkPhase thickness, µmSorption phase volume, microliter
Smart SPME Arrows | Solid Phase Microextraction Current 20103300.6
Smart SPME Fibers 20103300.6
SPME Fibers 20103300.6

Full specifications

Core Performance & Functional Specifications
Pack Quantity 3 pack
Needle gauge mfr 23 gauge
Arrow outside diameter mfr 1.1 mm
SPME fiber needle gauge mfr 23 gauge
SPME Arrow outside diameter mfr 1.1 mm
SPME Arrow inner core diameter mfr 0.4 mm
Dimensions, Weight & Mechanical Design
Arrow Length 20 mm
Fiber Length 10 mm
Electrical, Power & Drive Specifications
Phase Thickness 30 µm
Sorption Phase Volume 0.6 µL

Description

Construction and series positioning

Behavior and media

Installation and operation

Integration & Operating Notes

Process Limits
Phase chemistry must match analyte polarity class

The 30 µm PDMS phase is intended for nonpolar to semivolatile analytes. Polar volatiles require the 65 µm DVB/PDMS phase listed in the series documentation; using the PDMS Arrow for polar volatiles will give low recovery and is a method-selection error, not an instrument fault.

SPME Fundamentals, Agilent 5994-5775EN, scope and variants
Mounting
Verify autosampler accepts 1.1 mm OD arrow body

This Arrow has a 1.1 mm outside diameter and 23-gauge needle, while the series also includes a 1.5 mm OD variant. The autosampler guide, septum and injector port must be sized for the 1.1 mm body; forcing a mismatched arrow can bend the arrow or damage the septum.

SPME Fundamentals, Agilent 5994-5775EN, scope and variants
Maintenance
Condition and blank-run the Arrow before first use

New SPME phases carry manufacturing residue; the Arrow must be conditioned per the phase-specific instructions and blank-run until the baseline is clean before quantitative work. The supplied fundamentals digest does not state conditioning temperatures, so the phase-specific manual must be consulted.

SPME Fundamentals, Agilent 5994-5775EN
Control & I/O
Smart and non-Smart variants differ in identification

The series includes Smart (Yes/No) variants; the Smart feature provides automatic recognition by the instrument. Confirm which variant is being integrated, because the non-Smart version requires manual method entry of fiber type and does not report its identity to the controller.

SPME Fundamentals, Agilent 5994-5775EN, scope and variants

Selection & Integration Q&A

When should I choose this 1.1 mm OD, 20 mm Smart SPME Arrow over the 1.5 mm OD Arrow or a standard 10 mm SPME fiber?

Pick the 1.1 mm OD Arrow when the autosampler or injector accepts the smaller body and nonpolar semivolatiles are the target; the 1.5 mm OD Arrow suits wider-bore ports, and the 10 mm SPME fiber remains the lower-capacity option for standard fiber-based methods.

What adjacent system parts must be matched to this Arrow before installation?

The autosampler guide and injector septum must accept the 1.1 mm arrow body and 23-gauge needle, and the GC inlet liner must be sized for the 20 mm arrow length. The Smart variant requires an instrument that recognizes Smart fibers; otherwise use the non-Smart variant.

What mounting and duty-cycle limits apply to this Arrow in routine use?

The 1.1 mm OD body and 23-gauge needle are the mechanical limits: the arrow must travel through a correctly sized guide and septum, and repeated injections wear the septum and phase. The supplied digest gives no temperature or cycle-count limits, so those must come from the phase-specific manual.

What maintenance and consumables are needed, and what is not included in the base delivery?

The Arrow requires phase conditioning and periodic blank runs; septa, inlet liners and autosampler guides are wear items not part of the Arrow itself. The series is offered in 3-pack and 5-pack configurations, so pack size must be ordered explicitly; no cables or accessories are listed in the verified facts.