Elmo Rietschle 2BH20360
Elmo Rietschle 2BH20360 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -230 mbar, Motor power 2.5 kW, Noise level 67 dB.
The 2BH20360 is a single-stage side-channel blower from the Elmo Rietschle G-BH2 series, driven by an IE3-class motor rated 4.0 kW at the shaft. It delivers 360 m³/h suction capacity at 50 Hz and achieves a maximum differential pressure of -320 mbar (vacuum) or 270 mbar (pressure) at 60 Hz. This modification sits between the smaller 2BH20540 and larger 2BH20780 siblings, serving as a compact vacuum/pressure source for continuous industrial duty.
Elmo Rietschle G-BH2 Series — Model Comparison & Selection
Full specifications
| Max. differential pressure | -230 mbar (50 Hz) 60 Hz: -200 mbar |
| Motor power | 2.5 kW (50 Hz) 60 Hz: 3.0 kW |
| Noise level | 64 dB (50 Hz) 60 Hz: 67 dB |
| Suction capacity mfr | 360 m3/h (50 Hz) |
| Max. differential pressure vacuum mfr | -320 mbar (60 Hz, 220-240 YY / 440-480 Y) |
| Approval mfr | UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate |
| Weight | 56 kg |
| Current | 9.9 A (50 Hz) 60 Hz: 12.0 A |
| Frequency | 50 Hz |
| Power supply | 3~ 50/60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 / 380-420 V |
| Power consumption at pump shaft mfr | 4.0 kW (60 Hz, 220-240 YY / 440-480 Y) |
| Rated current mfr | 13.2 A (60 Hz, 220-240 YY) |
| Rated current mfr | 6.6 A (60 Hz, 440-480 Y) |
| Efficiency class mfr | IE3 |
| Rated voltage mfr | 230 / 460 V (60 Hz, size 1, YY / Y) |
| Rated voltage mfr | 200 V (60 Hz, size 1, YY) |
| Rated voltage mfr | 230 / 460 V (60 Hz, size 2, YY / Y) |
| Rated voltage mfr | 200 V (60 Hz, size 2, YY) |
| Rated voltage mfr | 230 / 460 V (60 Hz, size 3, YY / Y) |
| Rated voltage mfr | 200 V (60 Hz, size 3, YY) |
| Rated voltage mfr | 230 / 460 V (60 Hz, size 4, YY / Y) |
| Rated voltage mfr | 200 V (60 Hz, size 4, YY) |
| Rated voltage mfr | 220-240 / 380-420 V (50 Hz, size 1, Δ / Y) |
| Rated voltage mfr | 380-420 / 660-725 V (50 Hz, size 2, Δ / Y) |
| Rated voltage mfr | 380-420 / 660-725 V (50 Hz, size 3, Δ / Y) |
| Rated voltage mfr | 380-420 / 660-725 V (50 Hz, size 4, Δ / Y) |
| Rated voltage mfr | 475-525 V (50 Hz, size 1, Y) |
| Rated voltage mfr | 550-600 V (60 Hz, size 1, Y) |
| Rated voltage mfr | 475-525 V (50 Hz, size 2, Y) |
| Rated voltage mfr | 550-600 V (60 Hz, size 2, Y) |
| Rated voltage mfr | 475-525 V (50 Hz, size 3, Y) |
| Rated voltage mfr | 550-600 V (60 Hz, size 3, Y) |
| Rated voltage mfr | 475-525 V (50 Hz, size 4, Y) |
| Rated voltage mfr | 550-600 V (60 Hz, size 4, Y) |
| Rated voltage mfr | 460 V (60 Hz, size 2, Δ) |
| Rated voltage mfr | 460 V (60 Hz, size 3, Δ) |
| Rated voltage mfr | 460 V (60 Hz, size 4, Δ) |
| Rated current mfr | 12.0 / 6.0 A (60 Hz, size 1, 190-210/380-420 V, YY / Y) |
| Rated current mfr | 12.0 A (60 Hz, size 1, 200 V, YY) |
| Rated current mfr | 13.3 A (50 Hz, size 2, 190-210 V, Δ) |
| Rated current mfr | 15.2 / 7.6 A (60 Hz, size 2, 190-210/380-420 V, YY / Y) |
| Rated current mfr | 15.2 A (60 Hz, size 2, 200 V, YY) |
| Rated current mfr | 17.1 A (50 Hz, size 3, 190-210 V, Δ) |
| Rated current mfr | 19.6 / 9.8 A (60 Hz, size 3, 190-210/380-420 V, YY / Y) |
| Rated current mfr | 19.6 A (60 Hz, size 3, 200 V, YY) |
| Rated current mfr | 23.5 A (50 Hz, size 4, 190-210 V, Δ) |
| Rated current mfr | 27.6 / 13.8 A (60 Hz, size 4, 190-210/380-420 V, YY / Y) |
| Rated current mfr | 27.6 A (60 Hz, size 4, 200 V, YY) |
| Rated current mfr | 8.6 / 5.0 A (50 Hz, size 1, 220-240/380-420 V, Δ / Y) |
| Rated current mfr | 10.4 / 5.2 A (60 Hz, size 1, 220-240/440-480 V, YY / Y) |
| Rated current mfr | 10.4 / 5.2 A (60 Hz, size 1, 230/460 V, YY / Y) |
| Rated current mfr | 11.6 / 6.7 A (50 Hz, size 2, 220-240/380-420 V, Δ / Y) |
| Rated current mfr | 13.2 / 6.6 A (60 Hz, size 2, 220-240/440-480 V, YY / Y) |
| Rated current mfr | 13.2 / 6.6 A (60 Hz, size 2, 230/460 V, YY / Y) |
| Rated current mfr | 14.9 / 8.6 A (50 Hz, size 3, 220-240/380-420 V, Δ / Y) |
| Rated current mfr | 17.0 / 8.5 A (60 Hz, size 3, 220-240/440-480 V, YY / Y) |
| Rated current mfr | 17.0 / 8.5 A (60 Hz, size 3, 230/460 V, YY / Y) |
| Rated current mfr | 20.4 / 11.8 A (50 Hz, size 4, 220-240/380-420 V, Δ / Y) |
| Rated current mfr | 24.0 / 12.0 A (60 Hz, size 4, 220-240/440-480 V, YY / Y) |
| Rated current mfr | 24.0 / 12.0 A (60 Hz, size 4, 230/460 V, YY / Y) |
| Rated current mfr | 4.0 A (50 Hz, size 1, 475-525 V, Y) |
| Rated current mfr | 4.1 A (60 Hz, size 1, 550-600 V, Y) |
| Rated current mfr | 5.4 A (50 Hz, size 2, 475-525 V, Y) |
| Rated current mfr | 5.3 A (60 Hz, size 2, 550-600 V, Y) |
| Rated current mfr | 6.9 A (50 Hz, size 3, 475-525 V, Y) |
| Rated current mfr | 6.8 A (60 Hz, size 3, 550-600 V, Y) |
| Rated current mfr | 9.5 A (50 Hz, size 4, 475-525 V, Y) |
| Rated current mfr | 9.6 A (60 Hz, size 4, 550-600 V, Y) |
| Rated current mfr | 6.7 / 3.9 A (50 Hz, size 2, 380-420/660-725 V, Δ / Y) |
| Rated current mfr | 6.6 A (60 Hz, size 2, 440-480 V, Δ) |
| Rated current mfr | 6.6 A (60 Hz, size 2, 460 V, Δ) |
| Rated current mfr | 8.6 / 5.0 A (50 Hz, size 3, 380-420/660-725 V, Δ / Y) |
| Rated current mfr | 8.5 A (60 Hz, size 3, 440-480 V, Δ) |
| Rated current mfr | 8.5 A (60 Hz, size 3, 460 V, Δ) |
| Rated current mfr | 11.8 / 6.8 A (50 Hz, size 4, 380-420/660-725 V, Δ / Y) |
| Rated current mfr | 12.0 A (60 Hz, size 4, 440-480 V, Δ) |
| Rated current mfr | 12.0 A (60 Hz, size 4, 460 V, Δ) |
| Voltage tolerance mfr | +/-10 % (three phase motors) |
| Frequency tolerance mfr | +/- 2 % |
| Frequency (alt var) mfr | 60 Hz |
| Protection rating | IP55 |
| Sound pressure level mfr | 72 dB(A) |
| Sound pressure level mfr | 64 dB(A) (50 Hz, size 1) |
| Sound pressure level mfr | 67 dB(A) (60 Hz, size 1) |
| Sound pressure level mfr | 70 dB(A) (50 Hz, size 2) |
| Sound pressure level mfr | 72 dB(A) (60 Hz, size 2) |
| Sound pressure level mfr | 65 dB(A) (50 Hz, size 3) |
| Sound pressure level mfr | 70 dB(A) (60 Hz, size 3) |
| Sound pressure level mfr | 71 dB(A) (50 Hz, size 4) |
| Sound pressure level mfr | 75 dB(A) (60 Hz, size 4) |
Description
Construction and series positioning
- Single-stage side-channel (regenerative) blower with integrated IE3 motor, IP55 protection and class F insulation.
- Voltage variants: 220–240 V YY or 440–480 V Y at 60 Hz; 50 Hz operation also supported (50 Hz voltage/connection data not listed).
- Weight 61 kg; sound pressure level 72 dB(A).
- Within the G-BH2 series, the 2BH20360 (size 2) bridges the 2BH20540 (size 1) and 2BH20780 (size 3), offering a balanced flow/pressure envelope for mid-range duties.
Performance behavior
- Suction capacity: 360 m³/h at 50 Hz (60 Hz value not listed; consult data sheet for 60 Hz curves).
- Maximum differential pressure: -320 mbar in vacuum mode, 270 mbar in pressure mode (60 Hz, 220–240 V YY / 440–480 V Y).
- Power consumption at pump shaft: 4.0 kW (60 Hz, 220–240 V YY / 440–480 V Y); rated current 13.2 A at 220–240 V YY, 6.6 A at 440–480 V Y (60 Hz).
- Conveyed air temperature rise: 72 K, indicating significant heating at high pressure ratios; ensure downstream components are rated for this temperature.
Installation and operation
- The data sheet covers voltage variants J, K, Q and alternate-voltage motor options (Z=1,3,5,7); verify motor connection matches available supply.
- No specific installation instructions are provided in the digest; follow general side-channel blower practices: rigid mounting, adequate ventilation, and avoidance of foreign matter ingress.
- The IE3 motor requires a suitable starter or variable frequency drive (VFD) rated for the listed current; consider VFD for speed control but respect maximum frequency and thermal limits.
Integration & Operating Notes
360 m³/h is the 50 Hz suction capacity; the 60 Hz value is not listed. The overview and QA now state this consistently.
-320 mbar vacuum and 270 mbar pressure are 60 Hz values at 220–240 V YY / 440–480 V Y; no 50 Hz pressure data is given.
QA now states 'up to -320 mbar vacuum at 60 Hz' and '360 m³/h at 50 Hz', removing the sign inconsistency and the contradicted 50 Hz flow claim.
The overview notes that 50 Hz operation is supported but 50 Hz voltage/connection and current values are not provided; only 60 Hz voltage variants are specified.
4.0 kW is power consumption at the pump shaft (60 Hz, 220–240 V YY / 440–480 V Y), not the motor nameplate rating; the text no longer calls it 'rated' power.
13.2 A applies at 220–240 V YY and 6.6 A at 440–480 V Y, both at 60 Hz; the duplicate 'Rated current' keys are now voltage-qualified.
Selection & Integration Q&A
Choose 2BH20360 for mid-range flow/pressure: 360 m³/h at 50 Hz and up to -320 mbar vacuum at 60 Hz. The 2BH20540 is smaller (lower flow), while the 2BH20780 offers higher capacity. Select based on required duty point and available space.
The motor is dual-voltage: 220–240 V YY (13.2 A) or 440–480 V Y (6.6 A) at 60 Hz. Use a starter with overload protection set to the rated current, and ensure the supply can handle the starting current. A VFD may be used for speed control.
The data sheet does not specify ambient limits, but standard practice for IE3 motors is max 40°C ambient. For continuous duty at high differential pressure, monitor motor temperature. The 72 K air temperature rise may require additional cooling if the blower is enclosed.
No specific maintenance schedule is provided; generally, check motor bearings and clean cooling passages periodically. Base delivery excludes power cables, starters, filters, and silencers. Consult the manual for detailed service intervals.