Elmo Rietschle 2BH20540
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH20540

Elmo Rietschle 2BH20540 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -270 mbar, Motor power 4.6 kW, Noise level 71 dB.

The 2BH20540 is a side-channel regenerative blower in the Elmo Rietschle G-BH2 series, driven by a 4.6 kW IE3 motor rated for 190–210 V at 50 Hz or 200 V at 60 Hz. It delivers up to 170 mbar gauge pressure or -210 mbar vacuum, positioning it between the smaller 2BH20360 and larger 2BH20780 siblings. Its primary role is oil-free conveying, pressure, or vacuum generation in industrial processes.

Max. differential pressure
-270 mbar
Motor power
4.6 kW
Noise level
71 dB
Weight
83 kg

Elmo Rietschle G-BH2 Series — Model Comparison & Selection

Model Max. differential pressure, mbarMotor power, kWNoise level, dBWeight, kgCurrent, AVoltage, V
2BH20540 Current -2105.3678319.6190–210
2BH20360 -2002.567569.9190-210 / 380-420
2BH20780 -2207.37012027.6190–210

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -270 mbar (50 Hz)
60 Hz: -210 mbar
Motor power 4.6 kW (50 Hz)
60 Hz: 5.3 kW
Noise level 67 dB (50 Hz)
60 Hz: 71 dB
Order No. mfr 2BH20540-1AAK...
Certification mfr UL 1450 and CAN/CSA C22.2 No. 68-09 (certificate
Max. differential pressure vacuum mfr -210 mbar
Max. differential pressure (alt 50 Hz) mfr 240 mbar (50 Hz)
Max. differential pressure (alt 60 Hz) mfr 170 mbar (60 Hz)
Dimensions, Weight & Mechanical Design
Weight 83 kg
Number of stages 1
Electrical, Power & Drive Specifications
Current 17.1 A (50 Hz)
60 Hz: 19.6 A
Frequency 50 Hz
Power supply 3~ 50/60 Hz
Voltage 190-210 V (50 Hz)
60 Hz: 190-210 V
Motor efficiency class mfr IE3
Rated current mfr 19.6 A (50 Hz)
Frequency (alt var) mfr 60 Hz
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 67 dB(A)

Description

Construction and series positioning

Performance behavior

Installation and operation

Integration & Operating Notes

Electrical
Supply voltage must stay within 190–210 V at 50 Hz

Exceeding the upper voltage limit can overflux the motor and cause overheating; operating below the lower limit reduces starting torque and may trip overload protection. Verify site voltage and use a suitable transformer if the grid deviates.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 2BH20540 instead of the 2BH20360 or 2BH20780?

Choose the 2BH20540 when your required pressure or vacuum falls between the capacities of the 2BH20360 and 2BH20780. It offers a balanced 4.6 kW motor and 170/-210 mbar limits, avoiding oversizing of the larger unit or underperformance of the smaller one.

What are the power supply and protection requirements for this blower?

The motor requires a 190–210 V supply at 50 Hz or 200 V at 60 Hz, with rated current of 19.6 A (50 Hz) or 17.1 A (60 Hz). Use a motor protection circuit breaker or overload relay set to these currents, and ensure the supply can handle starting inrush.

What environmental and duty-cycle limits apply to the 2BH20540?

The IP55 motor allows dusty and damp environments but not immersion. Ambient temperature limits and duty cycle are detailed in the manual; typically continuous duty at rated load is permissible up to 40°C. Ensure adequate ventilation and avoid corrosive atmospheres.

What maintenance is required and what accessories are not included?

Regular maintenance includes checking the impeller for debris, inspecting bearings every 10,000 hours, and verifying electrical connections. The base delivery excludes suction/discharge silencers, filters, and flexible connectors; these must be ordered separately as needed.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — 2BH20540-1 IE3 vacuum pump (EN)
Datasheet ·243,6 КБ ·2 pp.