Elmo Rietschle 2BH20780
Elmo Rietschle 2BH20780 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -220 mbar, Motor power 6.3 kW, Noise level 75 dB.
The 2BH20780 is a side-channel (regenerative) blower from the Elmo Rietschle G-BH2 series, configured as a single unit with IP55 protection and class F insulation. It operates on 50/60 Hz with ±10% voltage and ±2% frequency tolerance, distinguishing it from smaller siblings 2BH20360 and 2BH20540 by its larger frame size. It serves as a vacuum or pressure source in pneumatic conveying, drying, or aeration systems where oil-free, pulsation-free air is required.
Elmo Rietschle G-BH2 Series — Model Comparison & Selection
Full specifications
| Max. differential pressure | -220 mbar 60 Hz: -150 mbar |
| Motor power | 6.3 kW (50 Hz) 60 Hz: 7.3 kW |
| Noise level | 70 dB (50 Hz) 60 Hz: 75 dB |
| Typ Nr. mfr | 2BH20780-1AAQQ3-BA |
| Frequenz mfr | 60 Hz |
| Zulassungen mfr | UL 1450, CAN/CSA 22.2 No 68-09 |
| Spannungstoleranz mfr | ± 10 % |
| Frequenztoleranz mfr | ± 2 % |
| Typ mfr | 2BH20780-1 |
| Max. Differenzdruck Vakuum mfr | -150 mbar (50 Hz) |
| Max. Differenzdruck Verdichter mfr | 120 mbar (50 Hz) |
| Effizienzklasse mfr | IE3 (50 Hz) |
| Bestell-Nr. mfr | 2BH20780-1AAKM1-BA |
| Max. Differenzdruck Vakuum mfr | -150 mbar (60 Hz) |
| Max. Differenzdruck Verdichter mfr | 120 mbar (60 Hz) |
| Effizienzklasse mfr | NP (60 Hz) |
| Max. Differenzdruck Verdichter (alt var) mfr | 200 mbar |
| Max. Differenzdruck Verdichter (alt 60 Hz) mfr | 120 mbar (60 Hz) |
| Weight | 120 kg |
| Number of stages | 1 |
| Current | 27.6 A (60 Hz (190-210 VYY / 380-420 VY)) 60 Hz (200 VYY): 27.6 A |
| Frequency | 50 Hz (50 Hz) 60 Hz: 60 Hz |
| Voltage | 190-210 V (50 Hz) 60 Hz: 190-210 V |
| Strom mfr | 27.6 A (50 Hz YY) |
| Strom mfr | 13.8 A (50 Hz Y) |
| Leistung mfr | 7.3 kW (50 Hz) |
| Strom mfr | 27.6 A (60 Hz YY) |
| Strom mfr | 13.8 A (60 Hz Y) |
| Leistung mfr | 7.3 kW (60 Hz) |
| voltage (alt 50 Hz) mfr | 380-420 V (50 Hz) |
| voltage (alt 60 Hz) mfr | 200 V (60 Hz) |
| Strom (alt 60 Hz (190-210 VYY / 380-420 VY)) mfr | 13.8 A (60 Hz (190-210 VYY / 380-420 VY)) |
| Protection rating | IP55 |
| Schalldruckpegel mfr | 75 dB(A) (50 Hz) |
| Schalldruckpegel mfr | 75 dB(A) (60 Hz) |
Description
Construction and series positioning
- The 2BH20780 is a side-channel blower with a regenerative impeller that accelerates air radially and tangentially, generating pressure or vacuum without oil or contact seals.
- Within the G-BH2 series, it is the largest of the three listed models (2BH20360, 2BH20540, 2BH20780), offering higher flow and pressure capability than the smaller siblings.
- The motor is integrated with the blower housing, rated IP55 and insulation class F, with UL 1450 and CAN/CSA 22.2 No 68-09 approvals (E225239).
Behavior under load and media
- No digitized curve points are available for this model; performance must be derived from the factory specification sheet or requested from the manufacturer.
- The blower is designed for continuous duty with air or neutral gases; the absence of internal lubrication makes it suitable for processes requiring oil-free air.
- Voltage and frequency tolerances (±10% and ±2%, respectively) allow operation on standard 50/60 Hz supplies without derating, but performance may vary slightly with supply fluctuations.
Installation, connection, and control
- No PDF digests are provided; installation and operation details must be taken from the official instruction manual.
- The blower is typically mounted horizontally on a rigid base; inlet and outlet connections are flanged or threaded according to the model's interface specifications.
- Electrical connection requires a suitable motor protection device; the IP55 rating permits outdoor installation but the terminal box must be sealed properly.
Integration & Operating Notes
Exceeding the ±10% voltage tolerance can cause motor overheating, reduced insulation life, or failure of the integrated thermal protection. The ±2% frequency tolerance also applies; operation outside these limits voids the UL/CSA approvals and may damage the motor windings.
The blower must be mounted horizontally on a foundation that dampens vibration; uneven or flexible mounting can lead to bearing wear, increased noise, and premature failure. Ensure sufficient clearance for cooling air intake and exhaust.
Operating beyond the maximum permissible pressure or vacuum (as per the performance curve) can cause motor overload, excessive temperature rise, and mechanical damage. The blower has no internal relief valve; system design must include external protection.
Accumulation of dust or debris on the impeller can cause imbalance and vibration. The maintenance schedule in the manual specifies periodic cleaning and bearing inspection; in dusty environments, shorten intervals accordingly.
Selection & Integration Q&A
Choose 2BH20780 when your required flow or pressure exceeds the capacity of the smaller siblings. It offers higher performance but also larger dimensions and power draw; verify the system curve against the 2BH20780 performance data.
The motor requires a 50/60 Hz supply within ±10% voltage and ±2% frequency. Use a motor protection circuit breaker or VFD with proper settings; ensure the supply can handle the starting current. The IP55 terminal box must be sealed with appropriate cable glands.
Regular maintenance includes cleaning the impeller and checking bearings. Consumables like filters, gaskets, and bearings are not included; order separately. The manual specifies intervals based on operating hours and environment.