Elmo Rietschle C-VLU 301
Elmo Rietschle C-VLU 301 — Claw Vacuum Pumps with Max inlet pressure 70 kPa, Pumping speed 265 m³/h, Ultimate pressure 30 mbar.
The C-VLU 301 is a contact-free, dry-running rotary claw vacuum pump with two gear-synchronised rotors, an oil-lubricated gearbox and a flanged 7.5 kW three-phase motor. It operates continuously at any intake pressure from 700 to 30 mbar (abs.) and delivers 265 m³/h at 50 Hz, distinguishing it within the C-VLU series by its mid-range displacement. It is intended for dry, non-aggressive gas service in industrial vacuum systems, with the XD variant available for water-vapour-laden gases.
Elmo Rietschle C-VLU Series — Model Comparison & Selection
Full specifications
| Max inlet pressure | 700 mbar |
| Operating principle | Klauen-Vakuumpumpe |
| Pumping speed | 265 m³/h (50 Hz) |
| Ultimate pressure | 30 mbar |
| Ambient temperature limit | +5 °C |
Description
Construction and series positioning
- Two-shaft rotary claw design with contact-free rolling claws; rotors are synchronised by a gear pair running in an oil-lubricated gearbox, while the compression chamber is sealed by piston rings and special seals.
- Integrated non-return valve on the inlet flange prevents venting of the evacuated system after shutdown; exhaust silencer and sound-insulating hood with drum fan are standard.
- Driven by a flanged three-phase standard motor via a coupling; motor flange screws are tightened to 84 Nm.
- Within the C-VLU series, the 301 sits between the smaller C-VLU 62 and the larger C-VLU 401; its 265 m³/h at 50 Hz and 30 mbar ultimate pressure define its mid-range duty. The XD variant adds a corrosion-protective coating for water-moist gases and includes a condensate purge (B2) not present on the standard model.
Behaviour under load and media
- Continuous operation is permitted at any pressure between 700 mbar (abs.) and 30 mbar (abs.) intake pressure; the pumping speed depends on intake pressure (see data sheet D 892).
- Maximum permissible back pressure is +30 mbar; the exhaust opening must not be closed or restricted, and no shut-off devices may be installed in the exhaust line.
- Standard model handles non-explosive, non-flammable, non-aggressive, non-toxic, dry gases and gas-air mixtures; the XD variant is additionally suitable for moist gases and water vapour.
- Frequent switching (approx. 10 times per hour) or elevated ambient/inlet temperatures may exceed motor winding and bearing temperature limits; consult the manufacturer for such duty.
- Installation above 1000 m above sea level causes noticeable performance reduction.
Installation, connection and operation
- Must be installed horizontally (max. 8° inclination in all directions) on a level, flat, load-bearing surface; secure against tipping.
- Provide at least 50 cm clearance around the machine for maintenance and keep cooling-air inlet/outlet at least 30 cm from adjacent walls; ambient temperature must be between +5 °C and +40 °C.
- Electrical installation by a qualified electrician per EN 60204; operator must provide a main switch and a motor protection switch. Motors are IP 55, insulation class F, and tolerate ±5 % voltage and ±2 % frequency deviation.
- Three-phase motors >5.2 kVA or with starting current >60 A are not designed for direct-on-line starting; use star-delta, soft starter or frequency converter. The 5.2 kVA threshold applies to this motor series, not as a general rule.
- Pressure monitoring on the inlet side is mandatory; if not supplied, the operator must install a pressure monitor that switches off the pump or brings it to a safe state if pressure falls below the minimum permissible final pressure.
- The pump has no built-in emergency stop/off; the operator must integrate it into the system safety concept.
- For variant XD, condensate must be drained regularly from the silencer; before shutdown for more than 2 hours, run the pump with dry air at 500 mbar (abs.) for at least 15–30 minutes.
Integration & Operating Notes
The exhaust silencer opening must remain unrestricted; installing any shut-off device or reducing the exhaust line cross-section can raise back pressure above the permissible +30 mbar, risking pump damage and invalidating performance data. Size the exhaust line for minimal pressure drop.
With a rated power of 7.5 kW at 50 Hz, the motor exceeds the 5.2 kVA threshold for direct-on-line starting. Use star-delta starting, a soft starter or a frequency converter to limit starting current and mechanical load on the coupling and rotors.
The pump is not supplied with pressure monitoring. The operator must install a pressure monitor on the inlet side that switches off the pump or brings it to a safe state if pressure falls below the minimum permissible final pressure (30 mbar abs.). Operation without this interlock is not permitted.
Cooling-air inlet and outlet must be at least 30 cm from adjacent walls, and exhaust cooling air must not be re-aspirated. Ambient temperature outside +5 °C to +40 °C requires consultation with the manufacturer; insufficient ventilation can cause overheating and reduced service life.
The 20,000-hour oil change interval applies only to Elmo Rietschle-approved oils (GEAR LUBE 150 or ECO GEAR LUBE 150). Extreme temperatures or contamination can shorten oil life to as little as 5,000 operating hours. Check oil level regularly and adjust intervals to actual duty.
The coupling ring gear is subject to wear and must be checked at least once a year; frequent starting and high ambient temperature shorten its life. A defective ring gear can lead to rotor shaft breakage and machine failure. When refitting the motor, tighten flange screws to 84 Nm.
Before shutdown for more than 2 hours, run the pump with dry air at 500 mbar (abs.) for at least 15–30 minutes to remove moisture and contamination. This prevents deposits that could block restart, especially when handling condensable vapours.
Selection & Integration Q&A
Choose the 301 when your required pumping speed at the working vacuum is around 265 m³/h at 50 Hz and ultimate pressure of 30 mbar is sufficient. The 62 is smaller; the 401 offers higher displacement. For water-vapour-laden gases, specify the XD variant of the 301.
The 7.5 kW motor requires a motor protection switch with delayed trip (due to cold-start inrush) and a main switch provided by the operator. Direct-on-line starting is not permitted; use star-delta, soft starter or VFD. Supply tolerance is ±5 % voltage and ±2 % frequency.
No, unless the ambient temperature is kept between +5 °C and +40 °C and cooling-air clearances (30 cm to walls, 50 cm for maintenance) are maintained. For higher temperatures or altitudes above 1000 m, consult the manufacturer for derating.
The base pump includes the pump, motor, coupling, silencer, sound-insulating hood and drum fan. Optional accessories such as intake filter (paper or polyester), flushing device (G 3/8 connection) and pressure monitor must be ordered separately. Spare parts kits and approved oils (GEAR LUBE 150) are available via spare parts list E 892.