Elmo Rietschle C-VLU 401
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle C-VLU 401

Elmo Rietschle C-VLU 401 — Claw Vacuum Pumps.

The C-VLU 401 is a contact-free, dry-running claw vacuum pump with oil-lubricated timing gears, driven by a flanged three-phase standard motor. It delivers 380 m³/h free-suction capacity at 50 Hz and sustains continuous operation from 700 mbar (abs.) down to 60 mbar (abs.) inlet pressure, distinguishing it within the C-VLU series by its mid-range displacement between the 301 and 501/651 sizes. It serves as a dry, oil-free process vacuum source in systems where the exhaust can be kept below +30 mbar back pressure and pressure monitoring is provided by the operator.

Elmo Rietschle C-VLU Series — Model Comparison & Selection

Model Max inlet pressure, kPaOperating principlePumping speed, m³/hUltimate pressure, mbarAmbient temperature limit, °C
C-VLU 401 Current —————
C-VLU 301 70Klauen-Vakuumpumpe265305
C-VLU 62 —————

Full specifications

Description

Construction and series positioning

Behaviour across the working range

Installation, connection and control

Integration & Operating Notes

Process Limits
Exhaust back pressure must stay below +30 mbar

Any silencer, pipe run or downstream treatment that raises exhaust pressure above +30 mbar exceeds the permissible limit and requires consultation with the manufacturer; liquids must not be allowed to accumulate in the exhaust line, and the exhaust opening must never be closed or restricted.

Operating Instructions BA 893-EN, Sections 2.4 and 5.3 Connection of Pipes
Control & I/O
Pressure monitor must trip the pump below minimum final pressure

No pressure monitoring is fitted at the factory and operation without it is not permitted. The operator must install a switch that shuts the pump down or moves it to a safe state when pressure falls below the minimum permissible final pressure on the rating plate, set with the ±5 % pressure tolerance in mind.

Operating Instructions BA 893-EN, Section 5.6 Connect Pressure Monitoring
Electrical
Large motors here are not direct-on-line startable

AC motors with apparent output above 1.7 kVA, three-phase motors above 5.2 kVA, or motors with start currents above 60 A are not designed for direct start on the network; use star-delta starting, a smooth starter or a frequency converter to limit mechanical load at start. Supply tolerances are ±5 % voltage and ±2 % frequency.

Operating Instructions BA 893-EN, Section 5.5.1 Motor Connection
Maintenance
Dry-run at 500 mbar before any stop longer than 2 hours

Before decommissioning or any shutdown exceeding 2 hours, run the pump at 500 mbar (abs.) for at least 15–30 minutes with dry air to remove moisture and pollution; otherwise condensate and deposits can adhere to rotors and casing and prevent restart. Oil level must be checked at the sight glass before commissioning.

Operating Instructions BA 893-EN, Sections 6.2.1 and 6 Check Lubricating Oil

Selection & Integration Q&A

When should I choose the C-VLU 401 rather than the C-VLU 301 or the larger 501/651 sizes?

Pick the 401 when the duty needs about 380 m³/h free suction at 50 Hz within 700–60 mbar (abs.). The 301 is smaller at 265 m³/h with 30 mbar ultimate; the 501/651 cover 495/600 m³/h. Choose the XD version of the 401 only if the gas is water-damp.

What must be provided around the C-VLU 401 for electrical supply, starting and pressure protection?

A qualified electrician must wire it per EN 60204 with a user-supplied main switch and motor protection switch. Motors above 1.7 kVA (AC) or 5.2 kVA (three-phase) or with start current over 60 A need star-delta, soft start or a frequency converter. A pressure monitor that trips below minimum final pressure is mandatory and not factory-fitted.

What maintenance routine and accessories are needed beyond the base pump delivery?

Base delivery excludes the intake filter (paper or polyester option), pressure monitoring and main/motor protection switches. Check oil at the sight glass before start-up and top up as needed; before any stop over 2 hours run at 500 mbar with dry air for 15–30 min. Spare parts are listed per model in the VLU 401/501/651 spare parts list.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — vacuum pump (BA 893-EN, ed. 1.0 08.04.2024, EN)
Manual ·1,7 МБ ·35 pp.
View PDF
PDF
Spare Parts List — vacuum pump (ed. 1.0 13.12.2024, EN)
Spare parts ·1,3 МБ ·12 pp.
View PDF