Elmo Rietschle SVT
Elmo Rietschle SVT — Screw Vacuum Pumps with Motor power 15 kW, Pumping speed 892 m³/h, Ultimate pressure 0.1 mbar.
The SVT is an oil-injected twin-screw vacuum pump with integrated variable-frequency control, delivering 892 m³/h pumping speed and 0.1 mbar ultimate pressure from a 15 kW motor. Its 1400–6780 rpm speed range distinguishes it within the SVT series, enabling demand-based throughput. It serves continuous vacuum generation in industrial processes requiring stable low-pressure performance.
Full specifications
| Lubrication type | oil-lubricated |
| Motor power | 15 kW |
| Operating principle | Twin-screw, oil-injected, variable-frequency controlled |
| Pumping speed | 892 m³/h |
| Ultimate pressure | 0.1 mbar |
| Rotational speed | 1400 - 6780 rpm |
| Weight | 765 kg |
| Weight (alt var) mfr | 198 kg |
| Power supply | 3 AC 400 V ±10 % |
| Oil capacity | 22 l |
| Noise level | 78 ± 3 dB |
| Ambient temperature limit | 5 to 40 (max 46 for continuous operation) °C |
Description
Construction and positioning
- Oil-injected twin-screw principle with integrated frequency converter (15–120 Hz) and 15 kW IE3 motor on 3 AC 400 V ±10 %.
- Compact drive version SVT 1000 IE3 15; oil capacity 22 l; unit mass 765 kg.
- Within the SVT series (SVT600–SVT6000), this model sits mid-range; larger siblings (SVT1500+) offer higher pumping speed, smaller ones suit lower flow demands.
Behavior under load and media
- Speed range 1400–6780 rpm allows throughput modulation; ultimate pressure 0.1 mbar.
- Oil-lubricated screws handle dry, non-explosive, non-abrasive gases; operating liquid (oil) quality and temperature govern stable performance.
- Noise level 78 ± 3 dB; surface temperatures up to ~80 °C require guarding.
Installation, control and operation
- Horizontal mounting only; floor-level installation needs no fastening but must be secured against falling.
- Suction port torque ≤100 Nm; discharge port hand-tight only. Flexible, de-energised connection to system; check valve if liquid carry-over risk.
- Electrical per IEC 60204-1; motor protection set to nameplate current; 3 AC 400 V ±10 % supply tolerance.
- Ambient 5–40 °C; continuous operation permitted up to 46 °C maximum; indoor/outdoor use with weather protection.
Integration & Operating Notes
Over-tightening the suction connection can crack the pump housing or distort the inlet flange. Use a torque wrench and tighten the discharge port by hand only to avoid damage.
Control stations must comply with EN 418 or IEC 417; each START must be located close to a STOP that takes priority. After a STOP or fault, restart only via a deliberately carried out procedure to prevent unexpected start-up.
Standard ambient range is 5–40 °C; continuous operation is permitted up to 46 °C. Above these limits, motor and converter overheating may occur. For outdoor installation, provide protection against rain, sunlight, snow and icing.
Selection & Integration Q&A
Choose SVT 1000 for 892 m³/h at 0.1 mbar with 15 kW. Larger siblings (SVT1500+) suit higher flow; smaller (SVT600/800) suit lower flow. The integrated VFC enables demand-based speed control from 1400–6780 rpm, avoiding external drives.
Supply 3 AC 400 V ±10 %, 50/60 Hz. Use a motor protection switch set to the nameplate rated current and follow IEC 60204-1.
Yes, indoors or outdoors with protection against rain, sunlight, snow and icing. Install horizontally on a level, rigid surface; floor-level needs no fastening but secure against falling. Ambient 5–40 °C; continuous operation permitted up to 46 °C maximum. Not for ATEX areas.
Base unit excludes check valve, level sensor LS-7, pressure switch, solenoid valve, thermostatic mixer (not for stainless steel), and cavitation protection. Plan bearing service every 2.5 years/20,000 h.