Elmo Rietschle VCD 202
Elmo Rietschle VCD 202 — Central Industrial & Medical Vacuum Systems with Motor power 4 kW, Noise level 69 dB, Pumping speed 200 m³/h.
The VCD 202 is an oil-flooded rotary vane vacuum pump in the VCD series, configured with a 4.0 kW IE3 motor for 50 Hz operation and delivering 200 m³/h nominal suction capacity at an ultimate vacuum of 3 mbar (abs.). It is distinguished from smaller and larger siblings by its G 2 suction and exhaust connections and an 8 l oil sump, making it suitable for central industrial vacuum systems requiring continuous duty in the 0.5–500 mbar (abs.) range.
Elmo Rietschle VCD Series — Model Comparison & Selection
Full specifications
| Motor power | 4.0 kW (50 Hz) |
| Noise level | 69 dB (50 Hz) 60 Hz: 76 dB |
| Pumping speed | 200 m3/h (50 Hz) 60 Hz: 240 m3/h |
| Ultimate pressure | 3 mbar |
| Rotational speed | 1465 rpm (50 Hz) 60 Hz: 1765 rpm |
| Nominal suction capacity mfr | 200 m3/h (50 Hz) |
| Nominal suction capacity mfr | 240 m3/h (60 Hz) |
| Motor efficiency mfr | 89.1 % (50 Hz) |
| Exhaust air outlet mfr | G 2 |
| Correct amount of oil mfr | 8 l |
| Weight | 195 kg (50 Hz) 60 Hz: 200 kg |
| Height | 402 mm XD design with additional gas ballast valve: 480 mm |
| Length | 840 mm (50 Hz) 60 Hz: 925 mm |
| Width | 523 mm |
| Current | 14.3 / 8.2 A (50 Hz) |
| Voltage | 230 / 400 V ± 10 % V (50 Hz) |
| Rated voltage (alt 50 Hz) mfr | 400 / 690 V ± 10 % V (50 Hz) |
| Inlet connection | G 2 |
| Outlet connection | G 2 |
| Height (without terminal box) mfr | 402 / 480 mm |
| Oil capacity mfr | 8 l |
| Sound pressure level (max.) mfr | 73 dB(A) (50 Hz) |
| Sound pressure level (max.) mfr | 76 dB(A) (60 Hz) |
| Average noise level (EN ISO 3744) mfr | 69 dB(A) (50 Hz) |
| Sound pressure level (max.) EN ISO 3744 mfr | 73 dB(A) (50 Hz) |
| Sound pressure level (max.) EN ISO 3744 mfr | 76 dB(A) (60 Hz) |
| Sound pressure level (max.) EN ISO 3744 (alt 50 Hz) mfr | 73 dB (50 Hz) |
Description
Construction and series positioning
- The VCD 202 is a single-stage, oil-flooded rotary vane pump with an integral non-return valve, gas ballast valve, micro filter on the intake, and oil-mist separator on the outlet. It is supplied with a sound cover and cooling fan.
- Within the VCD series, the 202 sits between the VCD 40 and VCD 400. Its 200 m³/h (50 Hz) nominal suction capacity and G 2 connections are larger than the VCD 40 but smaller than the VCD 400, which targets higher flow rates.
- The pump is available in standard, IV (reduced final vacuum, no gas ballast), and XD (increased water-vapour compatibility) designs. The VCD 202 standard design covers continuous intake pressures from 0.5 to 500 mbar (abs.); for permanent operation above 100 mbar (abs.), the next larger motor output must be used.
Behavior under load and media
- The ultimate vacuum is 3 mbar (abs.) for the standard design. Continuous operation outside the specified intake pressure range risks oil leakage through the outlet.
- Permissible media are air (with water vapour but no liquid water) and non-explosive, non-flammable, non-aggressive, non-poisonous dry gases. Explosive, flammable, aggressive, poisonous media, dust (ATEX zones 20–22), solvents, oxygen, and other oxidants are prohibited.
- Back pressure on the outlet must not exceed +0.1 bar; exceeding this can destroy components. For permanent operation above 100 mbar (abs.), the next larger motor output must be used.
- When evacuating closed systems, the volume to be evacuated must not exceed 2% of the nominal suction capacity (i.e., 4 m³ for the VCD 202 at 50 Hz).
Installation, connection, and operation
- The pump must be installed horizontally on a level, straight foundation capable of bearing its weight (195 kg at 50 Hz). Cooling air inlets and outlets require at least 30 cm clearance from walls, and 50 cm around the machine for maintenance.
- Electrical connection: 230/400 V ±10%, 50 Hz, 4.0 kW motor, 14.3/8.2 A current consumption, 1465 min⁻¹ speed. Voltage deviation of ±5% and frequency deviation of ±2% are permissible without derating. Motor protection class IP 55, insulation class F.
- Suction and exhaust connections are G 2; pipes must be screwed in by hand only. Oil filling: 8 l of ISO VG 100 oil (e.g., MULTI-LUBE 100, SUPER-LUBE 100, ECO-LUBE 100). Check oil level daily.
- Ambient and suction temperature must be between 12 and 40 °C. Storage conditions: 0–80% relative humidity, -10 to +60 °C. For storage over 3 months, use preservation oil.
Integration & Operating Notes
The exhaust line must be sized and routed to avoid any counter pressure above +0.1 bar. Sealing or constricting the exhaust air outlet may lead to destruction of components. Verify that any downstream piping, silencers, or filters do not introduce additional back pressure.
Operating the standard pump continuously outside this range risks oil leaking through the outlet opening. For permanent operation above 100 mbar (abs.), the next larger motor output must be used. For closed-system evacuation, the volume must not exceed 2% of nominal suction capacity (4 m³ at 50 Hz).
Use ISO VG 100 oil (e.g., MULTI-LUBE 100, SUPER-LUBE 100, ECO-LUBE 100). Reduce intervals if the discharged medium is contaminated. Oil separator elements (5x) must be replaced every 2000 operating hours or when filter resistance reaches 0.7 bar. Check oil level daily and top up to the upper edge of the sight glass.
Operation outside this range requires consultation with the manufacturer. For storage, relative humidity must be 0–80% and temperature -10 to +60 °C. For long-term storage (more than 3 months), use a preservation oil rather than operating oil.
Selection & Integration Q&A
Choose the VCD 202 when your required suction capacity is around 200 m³/h at 50 Hz and ultimate vacuum of 3 mbar (abs.) is sufficient. The VCD 40 is smaller, while the VCD 400 offers higher capacity. The VCD 202 also provides G 2 connections and an 8 l oil sump, suitable for medium-scale central vacuum systems.
The suction and exhaust connections are G 2 thread. Pipes must be screwed in by hand only. Ensure the exhaust line does not create back pressure exceeding +0.1 bar. For the suction line, use piping rated for the ultimate vacuum of 3 mbar (abs.) and avoid restrictive fittings that could limit flow.
Install horizontally on a level foundation able to bear 195 kg. Maintain 30 cm clearance for cooling air and 50 cm for maintenance. Ambient and suction temperature must be 12–40 °C. For continuous operation above 100 mbar (abs.), a larger motor is required. The pump is not suitable for explosive, flammable, or aggressive media.
The base delivery includes the pump with oil. For oil changes, use ISO VG 100 oil (8 l capacity). Oil separator elements (5x) must be replaced every 2000 h or at 0.7 bar. Air filters may be needed. No cables or remote control accessories are included; electrical connection parts must be supplied by the installer.