Elmo Rietschle VCD 202
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle VCD 202

Elmo Rietschle VCD 202 — Central Industrial & Medical Vacuum Systems with Motor power 4 kW, Noise level 69 dB, Pumping speed 200 m³/h.

The VCD 202 is an oil-flooded rotary vane vacuum pump in the VCD series, configured with a 4.0 kW IE3 motor for 50 Hz operation and delivering 200 m³/h nominal suction capacity at an ultimate vacuum of 3 mbar (abs.). It is distinguished from smaller and larger siblings by its G 2 suction and exhaust connections and an 8 l oil sump, making it suitable for central industrial vacuum systems requiring continuous duty in the 0.5–500 mbar (abs.) range.

Motor power
4 kW
Noise level
69 dB
Pumping speed
200 m³/h
Ultimate pressure
3 mbar
Weight
195 kg

Elmo Rietschle VCD Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBPumping speed, m³/hUltimate pressure, mbarWeight, kgCurrent, A
VCD 202 Current 46924031958.2–14.3
VCD 40 1.162400.5552.34–4.07
VCD 400 975120.135710.5–18.1

Full specifications

Core Performance & Functional Specifications
Motor power 4.0 kW (50 Hz)
Noise level 69 dB (50 Hz)
60 Hz: 76 dB
Pumping speed 200 m3/h (50 Hz)
60 Hz: 240 m3/h
Ultimate pressure 3 mbar
Rotational speed 1465 rpm (50 Hz)
60 Hz: 1765 rpm
Nominal suction capacity mfr 200 m3/h (50 Hz)
Nominal suction capacity mfr 240 m3/h (60 Hz)
Motor efficiency mfr 89.1 % (50 Hz)
Exhaust air outlet mfr G 2
Correct amount of oil mfr 8 l
Dimensions, Weight & Mechanical Design
Weight 195 kg (50 Hz)
60 Hz: 200 kg
Height 402 mm
XD design with additional gas ballast valve: 480 mm
Length 840 mm (50 Hz)
60 Hz: 925 mm
Width 523 mm
Electrical, Power & Drive Specifications
Current 14.3 / 8.2 A (50 Hz)
Voltage 230 / 400 V ± 10 % V (50 Hz)
Rated voltage (alt 50 Hz) mfr 400 / 690 V ± 10 % V (50 Hz)
Interfaces, Connections & Control
Inlet connection G 2
Outlet connection G 2
Height (without terminal box) mfr 402 / 480 mm
Materials, Media & Process Compatibility
Oil capacity mfr 8 l
Operating Conditions, Environment & Protection
Sound pressure level (max.) mfr 73 dB(A) (50 Hz)
Sound pressure level (max.) mfr 76 dB(A) (60 Hz)
Standards, Safety & General Data
Average noise level (EN ISO 3744) mfr 69 dB(A) (50 Hz)
Sound pressure level (max.) EN ISO 3744 mfr 73 dB(A) (50 Hz)
Sound pressure level (max.) EN ISO 3744 mfr 76 dB(A) (60 Hz)
Sound pressure level (max.) EN ISO 3744 (alt 50 Hz) mfr 73 dB (50 Hz)

Description

Construction and series positioning

Behavior under load and media

Installation, connection, and operation

Integration & Operating Notes

Process Limits
Exhaust back pressure must not exceed +0.1 bar

The exhaust line must be sized and routed to avoid any counter pressure above +0.1 bar. Sealing or constricting the exhaust air outlet may lead to destruction of components. Verify that any downstream piping, silencers, or filters do not introduce additional back pressure.

Operating Instructions BA 232-20-EN, Section 2.4, page 7; Section 5.3, page 16
Process Limits
Continuous intake pressure range is 0.5 to 500 mbar (abs.)

Operating the standard pump continuously outside this range risks oil leaking through the outlet opening. For permanent operation above 100 mbar (abs.), the next larger motor output must be used. For closed-system evacuation, the volume must not exceed 2% of nominal suction capacity (4 m³ at 50 Hz).

Operating Instructions BA 232-20-EN, Section 4.3, page 14
Maintenance
First oil change after 500 hours, then every 500–2000 hours

Use ISO VG 100 oil (e.g., MULTI-LUBE 100, SUPER-LUBE 100, ECO-LUBE 100). Reduce intervals if the discharged medium is contaminated. Oil separator elements (5x) must be replaced every 2000 operating hours or when filter resistance reaches 0.7 bar. Check oil level daily and top up to the upper edge of the sight glass.

Operating Instructions BA 232-20-EN, Section 7.2.3, page 23; Section 7.2.4, page 24
Environment
Ambient and suction temperature must stay between 12 and 40 °C

Operation outside this range requires consultation with the manufacturer. For storage, relative humidity must be 0–80% and temperature -10 to +60 °C. For long-term storage (more than 3 months), use a preservation oil rather than operating oil.

Operating Instructions BA 232-20-EN, Section 2.3, page 7; Section 3.2.1, page 11

Selection & Integration Q&A

When should I choose the VCD 202 over the VCD 40 or VCD 400?

Choose the VCD 202 when your required suction capacity is around 200 m³/h at 50 Hz and ultimate vacuum of 3 mbar (abs.) is sufficient. The VCD 40 is smaller, while the VCD 400 offers higher capacity. The VCD 202 also provides G 2 connections and an 8 l oil sump, suitable for medium-scale central vacuum systems.

What are the requirements for connecting the VCD 202 to my existing vacuum piping?

The suction and exhaust connections are G 2 thread. Pipes must be screwed in by hand only. Ensure the exhaust line does not create back pressure exceeding +0.1 bar. For the suction line, use piping rated for the ultimate vacuum of 3 mbar (abs.) and avoid restrictive fittings that could limit flow.

What are the mounting and duty-cycle limitations for the VCD 202?

Install horizontally on a level foundation able to bear 195 kg. Maintain 30 cm clearance for cooling air and 50 cm for maintenance. Ambient and suction temperature must be 12–40 °C. For continuous operation above 100 mbar (abs.), a larger motor is required. The pump is not suitable for explosive, flammable, or aggressive media.

What maintenance items and accessories are required but not included with the base pump?

The base delivery includes the pump with oil. For oil changes, use ISO VG 100 oil (8 l capacity). Oil separator elements (5x) must be replaced every 2000 h or at 0.7 bar. Air filters may be needed. No cables or remote control accessories are included; electrical connection parts must be supplied by the installer.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Operating Instructions — vacuum pump (BA 232-20-EN, ed. 1.2 9.2.2018, EN)
Manual ·2,6 МБ ·32 pp.
View PDF
PDF
Technical Data Sheet — IE3 vacuum pump DE/EN)
Datasheet ·661,3 КБ ·3 pp.
View PDF