Peter Huber Kältemaschinenbau HB240 Umwälz-Heizgerät
Peter Huber Kältemaschinenbau HB240 Umwälz-Heizgerät — Thermostatic baths.
The HB240 is a 24 kW, 400 V three-phase heating bath circulator for external open operation, delivering 60–250 °C with a magnetically coupled stainless-steel pump (up to 100 l/min, 3.5 bar). It has no expansion tank, so the external application must provide filling and volume compensation. It is the mid-high capacity unit in the HB series, positioned between the HB120 and HB480.
Direct drop-in replacements
Peter Huber Kältemaschinenbau Umwaelz Heizgeraete Series — Model Comparison & Selection
| Model | Dimensions w d h | Power supply | Pump connection | Pump type | Heating capacity, W | Ambient temperature limit, °C |
|---|---|---|---|---|---|---|
| HB240 Umwälz-Heizgerät Current | 570 x 700 x 1171 | 400V 3~ 50Hz | M30x1, 5 AG male | magnetically coupled, st | 24000 | 5–40 |
| HB120 Umwälz-Heizgerät | 479 x 539 x 695 | 380-460V 3~ 50/60Hz | M30x1, 5 AG male | magnetically coupled, st | — | 5–40 |
| HB480 Umwälz-Heizgerät | 570 x 700 x 1171 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 48000 | 5–40 |
| HB60 Umwälz-Heizgerät | 323 x 451 x 498 | 400V 3~N 50Hz | M30x1, 5 AG male | Pressure pump, speed not | 6000 | 5–40 |
| HB720 Umwälz-Heizgerät | 800 x 1007 x 1607 | 400V 3~ 50Hz | M38x1, 5 AG male | magnetically coupled, st | 72000 | 5–40 |
Full specifications
| Dimensions (w × D × H) | 570 x 700 x 1171 mm |
| Heating capacity | 24 kW |
| Pump connection | M30x1, 5 AG male |
| Pump speed adjustable | Yes |
| Pump type | magnetically coupled, stainless steel |
| External sensor connection | Pt100 |
| Temperature range | 60...250 °C |
| Power supply | 400V 3~ 50Hz |
| Controller | Pilot ONE |
| Display resolution | 0, 01 K |
| Digital interface | Ethernet, USB (Host u. Device), RS232 |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Safety class | II / FL |
Description
Construction and series positioning
- The HB240 is a stainless-steel heating bath circulator (heating, housing and pump in stainless steel) with a magnetically coupled, variable-speed pressure pump and M30x1.5 male pump connection.
- It is designed exclusively for external open operation and has no expansion tank; the external circuit must supply filling and volume compensation.
- Within the HB series (HB45, HB60, HB120, HB240, HB480), the HB240 sits above the HB120 and below the HB480 in heating capacity; the 24 kW rating and 60–250 °C range define its place.
- Control is via the Pilot ONE controller with 0.01 K display resolution; interfaces include Ethernet, USB (host and device) and RS232; an external Pt100 sensor can be connected.
Behavior under load and media
- The 24 kW heating power supports the 60–250 °C range; the minimum temperature of 60 °C is reachable only if ambient temperature is below 60 °C and application heat loss is between 0.1 kW and 2.8 kW (depending on HB model).
- The circulation pump delivers up to 100 l/min at up to 3.5 bar; the external circuit pressure drop must be checked against this.
- The unit is EMC class A, group 1 (EN 55011), intended for industrial environments; it may cause radio interference in residential areas.
- Safety classification II/FL with adjustable overtemperature protection per DIN 12876; leakage current from the external temperature control must be considered for earthing and RCD selection.
Installation, connection and operation
- Power supply is 400 V 3~ 50 Hz; the unit is delivered with cable but without a plug, so the customer must provide a suitable three-phase connection and plug.
- Voltage and frequency tolerances are ±10% only if they do not act in opposite directions; supply quality must be verified before commissioning.
- Ambient temperature must remain between 5 °C and 40 °C; protection rating is IP20.
- Pump connection is M30x1.5 male; mating hoses or adapters must match this thread.
Integration & Operating Notes
Because the HB240 has no expansion tank and is designed exclusively for external open operation, the external application must supply the filling volume and compensate for thermal expansion; otherwise the unit cannot operate correctly.
The unit is delivered with a cable but without a plug for three-phase devices under 63 A, so the customer must provide a suitable 400 V three-phase plug and connection by a qualified electrician.
To reach the 60 °C minimum temperature, ambient must be below 60 °C and the external application heat loss must fall between 0.1 kW and 2.8 kW depending on the HB model; outside this window the minimum temperature may not be achieved.
The unit is classified EMC class A, group 1 to EN 55011, so it may cause radio interference in residential areas and is intended for industrial environments; consider EMC coordination if installed near sensitive electronics.
Leakage current from the external temperature control must be considered when selecting protective devices and earthing; proper earthing and RCD selection are required.
The circulation pump delivers up to 100 l/min at up to 3.5 bar; the pressure drop of the external application must be checked to ensure the pump can overcome it.
The unit has adjustable overtemperature protection according to DIN 12876 and safety classification II/FL; the installer must configure the limit to protect the external application and fluid.
Selection & Integration Q&A
Choose the HB240 when 24 kW heating and 60–250 °C suit your load; the HB120 offers lower capacity and the HB480 higher. The HB240 sits between them in the series, so match heating power and pump duty to your application heat loss and circuit pressure drop.
Provide an external open circuit with filling and volume compensation (no expansion tank on the unit), hoses or adapters with M30x1.5 female thread, and a 400 V 3~ 50 Hz supply with a suitable plug (cable supplied without plug). Verify voltage/frequency within ±10% without opposing deviation.
The base delivery includes a cable but no plug, so a 400 V three-phase plug is required. No maintenance schedule or consumables are specified in the available datasheet; use stainless-steel-compatible thermofluid and cleaning agents, and set the adjustable overtemperature protection for the application.