Peter Huber Kältemaschinenbau KISS K20 Kälte-Badthermostat
Peter Huber Kältemaschinenbau KISS K20 Kälte-Badthermostat — Thermostatic baths with Noise level 50 dB.
The KISS K20 is a 17-litre refrigerated bath thermostat with a pressure/suction pump and a -30 to 200 °C working range, positioned between the K15 and K25 in the KISS series. Its air-cooled R-290 refrigeration stage delivers 0.4 kW at 20 °C but only 0.065 kW at -30 °C, so it suits sub-ambient and high-temperature bath duties where heat loads are modest at the cold end.
Direct drop-in replacements
Peter Huber Kältemaschinenbau KISS Series — Model Comparison & Selection
| Model | Noise level, dB | Power supply | Pump connection | Temperature range, °C | Weight, kg | Filling volume, m³ |
|---|---|---|---|---|---|---|
| KISS K20 Kälte-Badthermostat Current | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 41 | 0.01 |
| KISS K12 Kälte-Badthermostat | — | 110-115V 1~ 50/60Hz | (Option, #19607) | -20–200 | 28 | — |
| KISS K25 Kälte-Badthermostat | 50 | 220-240V 1~/2~ 50/60Hz | (Option, #19607) | -30–200 | 39 | 0.015 |
| KISS K6 Kälte-Badumwälzthermostat | 57 | 208-240V 1~/2~ 50/60Hz | M16x1 AG male | -25–200 | 25 | 0.002 |
| KISS K6s Kälte-Badumwälzthermostat | 57 | 208-240V 1~/2~ 50/60Hz | M16x1 AG male | -25–200 | 25 | 0.002 |
Full specifications
| Noise level | 50 dB(A) |
| Alarm output | optic, acoustic |
| Bath volume | 17 l |
| Dimensions (w × D × H) | 350 x 555 x 615 mm |
| Filling volume | 10 l (min.) |
| Maximum delivery flow rate | 14 l/min (pressure pump max.; 0, 25 bar) |
| Pump connection | (Option, #19607) (Option) |
| Pump speed adjustable | no |
| Pump type | Pressure and suction pump, speed not variable |
| Refrigerator | air-cooled, natural refrigerant |
| Temperature range | -30...200 °C |
| Temperature stability mfr | ±0, 05 K |
| Heating capacity mfr | 1, 8 - 2, 1 kW |
| Delivery capacity suction pump max. mfr | 10, 5 l/min (suction pump max.; 0, 17 bar) |
| Bath opening WxD/BD mfr | 290 x 329 / 150 |
| Weight | 41 kg |
| Power supply | 220-240V 1~/2~ 50/60Hz |
| Current consumption max. mfr | 10 + 2 A (max.) |
| Controller | KISS |
| Digital interface | USB (Device), RS232 Interface |
| Temperature display | OLED Display |
| Refrigerant | R-290 (A3, H220) (1st stage) |
| Refrigerant quantity 1st stage mfr | 0, 072 kg (1st stage) |
| Ambient temperature limit | 5...40 °C |
| Protection rating | IP20 |
| Cooling capacity mfr | 20: 0, 4; 0: 0, 35; -10: 0, 27; -20: 0, 16; -30: (at °C) |
| Safety class | III / FL |
Description
Construction and series positioning
The KISS K20 is a benchtop refrigerated bath thermostat with a 17 l bath and a 290 x 329 mm opening (150 mm depth), built around a KISS controller with OLED display. Within the KISS series it sits between the K12/K15 and the K25: the K20 offers more bath volume than the smaller siblings while sharing the 50 dB(A) noise level of the K25, whereas the K6 circulating variant is louder at 57 dB(A). The unit is 350 x 555 x 615 mm and weighs 41 kg.
Thermal behaviour
- Working range: -30 to 200 °C, with ±0.05 K stability and 1.8–2.1 kW heating capacity.
- Cooling capacity is strongly temperature-dependent: 0.4 kW at 20 °C, 0.35 kW at 0 °C, 0.27 kW at -10 °C, 0.16 kW at -20 °C and 0.065 kW at -30 °C. Size the process heat load against the capacity at the actual setpoint, not the nominal 20 °C figure.
- The pressure and suction pump is not speed-variable; maximum delivery is 14 l/min on the pressure side and 10.5 l/min on the suction side.
Installation, control and operation
The refrigeration circuit uses R-290 (A3, H220) with 0.072 kg charge in the first stage and an air-cooled condenser, so ventilation and clearance around the unit are mandatory. Electrical supply is 220–240 V, 1~ or 2~, 50/60 Hz, with maximum current consumption of 10 + 2 A. Control and monitoring are via the KISS controller with OLED display, USB device port and RS232 interface; alarm signalling is optic and acoustic. Overtemperature protection is adjustable per DIN 12876, safety class III/FL, and an autostart function restarts the unit after power failure.
Integration & Operating Notes
Voltage may deviate by no more than ±5 % and frequency by ±2 %; the combination of -5 % voltage with +2 % frequency is explicitly not allowed. Verify the site supply before connection, especially on generator-fed or weak grids, because simultaneous deviations can damage the compressor.
The standard plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). Select an alternative heat transfer fluid or specify a more resistant pump variant at order; otherwise pump failure and fluid contamination are likely.
For operation near or below 0 °C the manufacturer recommends mixing water with glysantine or ethylene glycol rather than using pure water, to prevent freezing and damage to the bath and pump circuit.
The refrigerating unit is air-cooled; respect the space requirements around the unit and keep ambient temperature between 5 and 40 °C. Cooling capacity may drop when ambient rises above 20 °C, so size the installation for the actual room conditions.
The Pt100 sensor connection (option #10688) is factory-fitted only and is used to display, not control, an external process temperature. If external monitoring is required, specify it with the order; it cannot be retrofitted later.
An autostart function restarts the unit automatically after a mains interruption. Evaluate whether unattended restart is acceptable for your process and samples; if not, the restart behaviour must be addressed in the site safety concept.
The unit is classified Class A, Group 1 to EN55011, intended for industrial environments; it may cause interference in residential areas. Coordinate EMC with adjacent sensitive instrumentation if installed outside a dedicated lab zone.
Selection & Integration Q&A
Pick the K20 when you need a 17 l bath and the -30 to 200 °C range with modest cold-end loads; the K15 offers less bath volume, the K25 more, and the K6 circulating variant is louder at 57 dB(A) versus 50 dB(A).
A 220–240 V, 1~ or 2~, 50/60 Hz supply rated for the 10 + 2 A maximum current, with voltage within ±5 % and frequency within ±2 %; the combination of -5 % voltage and +2 % frequency is not permitted.
In a dry, protected location (IP20, no water spray) with ambient between 5 and 40 °C and adequate air flow around the air-cooled condenser; cooling capacity may drop above 20 °C ambient, so size for the actual room temperature.
The Pt100 sensor connection (#10688, display only) and the pump connection option (#19607) are factory options, not standard; the heat transfer fluid and freeze-protection glycol mixture are user-supplied, and the pump is not speed-variable.