Peter Huber Kältemaschinenbau KISS K12 Kälte-Badthermostat
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau KISS K12 Kälte-Badthermostat

Peter Huber Kältemaschinenbau KISS K12 Kälte-Badthermostat — Thermostatic baths.

The KISS K12 is a 10.5-litre refrigerated bath thermostat with a pressure/suction pump, rated -20 to 200 °C and ±0.05 K stability. Within the KISS series it is the mid-volume unit, distinguished by 1.5 kW heating and 0.25 kW cooling at 20 °C. It serves as a temperature-controlled source for external circuits or direct bath immersion.

Direct drop-in replacements

Eppendorf
MixMate ®
71%
match
⚖️ Compare

Peter Huber Kältemaschinenbau KISS Series — Model Comparison & Selection

Model Noise level, dBPower supplyPump connectionTemperature range, °CWeight, kgFilling volume, m³
KISS K12 Kälte-Badthermostat Current —110-115V 1~ 50/60Hz(Option, #19607)-20–20028—
KISS K20 Kälte-Badthermostat 50220-240V 1~/2~ 50/60Hz(Option, #19607)-30–200410.01
KISS K25 Kälte-Badthermostat 50220-240V 1~/2~ 50/60Hz(Option, #19607)-30–200390.015
KISS K6 Kälte-Badumwälzthermostat 57208-240V 1~/2~ 50/60HzM16x1 AG male-25–200250.002
KISS K6s Kälte-Badumwälzthermostat 57208-240V 1~/2~ 50/60HzM16x1 AG male-25–200250.002

Full specifications

Core Performance & Functional Specifications
Maximum delivery flow rate 14 l/min (pressure pump max, 0, 25 bar)
Pump connection (Option, #19607) (Option)
Pump speed adjustable no
Pump type Pressure and suction pump, speed not variable
Temperature range -20...200 °C
Temperature stability mfr ±0, 05 K
Alarm message mfr optic, acoustic
Dimensions (W x D x H) mfr 350 x 560 x 430 mm
Heating capacity mfr 1, 5 kW
Delivery capacity suction pump max. mfr 10, 5 l/min (suction pump max, 0, 17 bar)
Bath opening WxD/BD mfr 290 x 152 / 150
Bath volume mfr 10, 5 l
Filling volume min. mfr 7, 5 l (min)
Dimensions, Weight & Mechanical Design
Weight 28 kg
Electrical, Power & Drive Specifications
Power supply 110-115V 1~ 50/60Hz
Current consumption max. mfr 15 + 2, 6 A (max)
Interfaces, Connections & Control
Controller KISS
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Cooling capacity mfr 20: 0, 25; 0: 0, 2; -10: 0, 12; -20: 0, 05 kW (at °C)
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

Thermal behaviour

Control, connection and operation

Integration & Operating Notes

Electrical
Verify 110–115 V supply and 10 A fuse before commissioning

The unit requires 110–115 V single-phase 50/60 Hz with a minimum 10 A fuse; max current is 15 + 2.6 A. Voltage tolerance is ±5% only with ±2% frequency, and -5% voltage with +2% frequency is not allowed. A country-specific plug must be specified at ordering.

Datasheet, Specifications; Installation notes
Process Limits
Check heat load at the coldest set point, not at 20 °C

Cooling capacity drops from 0.25 kW at 20 °C to 0.05 kW at -20 °C. Size the refrigerating duty against the actual heat load at the lowest required temperature; ambient above 5–40 °C further reduces capacity.

Datasheet, Specifications
Cooling & Media
Avoid acetone and polyglycols with the standard plastic pump

The plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). For freeze protection, mix water with glysantine or ethylene glycol rather than using pure water.

Datasheet, Operation notes
Mounting
Install in a dry, non-condensing location; IP20 only

IP20 protection means the unit must be kept from water ingress and condensation. The refrigerant R-290 (A3, H220) is flammable, so room ventilation and ignition-source planning apply. EMC Class A, Group 1 may cause interference in residential settings.

Datasheet, Installation notes
Control & I/O
Pt100 option is display-only and must be ordered factory-fitted

The optional Pt100 sensor connection (#10688) displays, but does not control, process temperature and is only available factory fitted. USB (Device) and RS232 are standard; pump connection option #19607 is separate.

Datasheet, Options

Selection & Integration Q&A

When should I choose the KISS K12 rather than a sibling K6, K15, K20 or K25?

Pick the K12 for a 10.5 l bath with 1.5 kW heating and 0.25 kW cooling at 20 °C. The K6 is smaller; K15/K20/K25 offer larger baths. Confirm the required bath volume and coldest-set-point heat load before deciding.

What must be verified on the electrical supply and plug before ordering?

The K12 needs 110–115 V 1~ 50/60 Hz with a minimum 10 A fuse; max current is 15 + 2.6 A. Voltage tolerance is ±5% only with ±2% frequency. A country-specific plug must be specified at ordering.

What installation environment and duty limits apply?

Ambient must stay 5–40 °C; cooling capacity may fall as ambient rises. IP20 requires a dry, non-condensing location. R-290 (A3, H220) is flammable, so ventilation and ignition-source planning are needed. EMC is Class A, Group 1.

Which accessories or consumables are not included and must be planned separately?

The country-specific plug must be specified at ordering. The Pt100 sensor connection (#10688) is factory-fitted only and display-only; pump connection #19607 is an option. Bath fluid (water with glysantine or ethylene glycol) is not supplied.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
KISS K12 Immersion Circulator
Datasheet ·30,0 КБ ·2 pp.
View PDF