Nabertherm F 30
Nabertherm F 30 — Fusing furnaces.
The Nabertherm F 30 is a top-loading fusing furnace with a 410 × 410 × 230 mm chamber and 950 °C maximum temperature, powered by a 2 kW single-phase connection. It is the smallest model in the F-series, positioned below the F 75 and F 110 for low-throughput fusing and glass melting where floor space is limited to 0.13 m².
Nabertherm Top Loader as Fusing Furnaces | Nabertherm Series — Model Comparison & Selection
Full specifications
| Electrical connection | 1-phase |
| Nominal power | 2 kW |
| Floor space mfr | 0.13 |
| Inner dimensions (W × D × H) mfr | 410 × 410 × 230 mm |
| Outer dimensions (W × D × H) mfr | 640 × 770 × 585 mm |
| Weight | 55 kg |
| Max temperature | 950 °C |
Description
Construction and series positioning
- Top-loader architecture with a manually lifted lid; chamber dimensions 410 × 410 × 230 mm (W × D × H) and outer dimensions 640 × 770 × 585 mm.
- Weighs 55 kg and occupies 0.13 m² of floor space, making it the most compact of the F-series siblings (F 75, F 110).
- Single-phase electrical connection at 2 kW nominal power; no three-phase or high-power variant is indicated for this model.
Thermal behavior and process role
- Maximum operating temperature is 950 °C, suitable for fusing, glass melting, and similar processes that do not require higher-temperature chamber furnaces.
- No digitized curve points are available for this model; heating and cooling behavior must be derived from the controller configuration and load.
- The top-loading design provides unobstructed access to the chamber from above, which is advantageous for loading crucibles or large flat charges.
Control and integration
- The furnace is compatible with Nabertherm's standard controller series 500 and the MyNabertherm app for process data storage and temperature control (per the Prozesssteuerung document).
- No specific controller is included in the base delivery; the controller must be selected and ordered separately according to the required functions (e.g., program control, data recording).
- Installation requires a single-phase supply sized for 2 kW; no other electrical specifications (voltage, current) are provided in the verified facts.
Integration & Operating Notes
The furnace does not include a controller in the base scope. Nabertherm offers the series 500 controllers and MyNabertherm app for programming and data logging. The specific controller model and any required thermocouples or interface modules must be ordered separately and matched to the 950 °C maximum temperature.
Operating above 950 °C risks damage to heating elements and insulation. Loads must be placed to avoid contact with the lid seal or heating elements when the lid is closed. The chamber dimensions (410 × 410 × 230 mm) define the maximum charge size; overloading can cause uneven heating and premature element failure.
Selection & Integration Q&A
Choose the F 30 for small batches or low-throughput fusing where the 410 × 410 × 230 mm chamber and 950 °C limit are sufficient and floor space is tight (0.13 m²). The F 75 and F 110 offer larger chambers but require more space and power; select them only if you need higher capacity.
The F 30 requires a single-phase 2 kW supply and a separate controller. Nabertherm's series 500 controllers or MyNabertherm app can be used for programming and data logging. Ensure the controller supports type K or appropriate thermocouples for 950 °C and that the supply circuit is dedicated and properly fused.
Base delivery excludes controller, thermocouples, and process recording accessories. Periodic maintenance includes checking heating elements and door seal, and calibrating the controller. No specific maintenance interval is given in the verified facts; refer to the manual for recommended schedules.