Agilent Technologies Fragment Analyzer Capillary Arrays
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Fragment Analyzer Capillary Arrays

Agilent Technologies Fragment Analyzer Capillary Arrays — Automated electrophoresis.

The Agilent Fragment Analyzer Capillary Arrays are 12-capillary consumable arrays for the 5200/5300/5400 Fragment Analyzer systems, offered in ultrashort, short and long formats. They enable automated electrophoresis with a 22 cm effective length, 2 µL sample consumption and 50 min analysis time, delivering sizing and quantification for DNA/RNA QC.

Agilent Technologies Fragment Analyzer Systems Series — Model Comparison & Selection

Model Measurement rangePlate capacityAverage sizing of 2 200 nt ivt mrna, ntLower marker size of hs rna kit, ntMaximum ivt mrna sample size analyzed, ntSample volume per well, microliter
Fragment Analyzer Capillary Arrays Current —12———2
5200 Fragment Analyzer ——23701560002
5300 Fragment Analyzer ——2370156000—
RNA QC, DNA QC, Fragment Analyzer —12———2
Ultra-high-throughput fragment analysis 5400 Fragment Analyzer 0.5nine plates2370156000—

Full specifications

Core Performance & Functional Specifications
Analysis time 50 min
Analysis Time6 55 min
Analysis Time7 40 min
Detector type Charged Coupled Device
Plate capacity 12 samples
Sample Input Volume 2 µL
Sample volume 2 µl
Sample Volume Per Well 2 µL
Separation resolution mfr 3 bp
Dilutions per sample mfr single single
Gel capacity mfr Two gel gel
Input concentration dynamic range mfr two orders of magnitude magnitude
RQN quality score scale mfr 1...10
Sizing range mfr 200 nt
Sizing accuracy mfr 20
Sizing precision mfr 20
Quantification accuracy mfr 30
Quantification precision mfr 20
Quantification range (DNA Fragment) mfr 0.1 ng/μL
Quantification range (DNA Smear) mfr 5 ng/μL
Guaranteed shelf life mfr 4 months
Kit size mfr 500 samples
DNA fragment concentration range mfr 0.5 ng/μL
Number of capillaries mfr 12 capillaries
RQN scale mfr 1...10
Capillary arrays mfr 12 arrays
n–1 resolution mfr 60 nt
Samples separated per run mfr 12 samples
Maximum queued samples mfr 288 samples
Capillary counts mfr 12 capillaries
sample separation time mfr 30 minutes
samples per run mfr 12 samples
capillary array options mfr 12 arrays
resolution range mfr 60 nt
Maximum DNA concentration mfr 600 sample
Limit of detection (S/N > 3) or sensitivity mfr 50 pg/μL
Input concentration range mfr 50 pg/μL
Quantitative range mfr 50 pg/μL
Maximum DNA concentration per fragment mfr 600 pg/μL
Maximum DNA concentration per total sample mfr 5 ng/μL
Final sample volume (Plasmid DNA Kit) mfr 24 μL
Dimensions, Weight & Mechanical Design
Effective Length 22 cm
Length 47 cm
Effective length (FA 12-Capillary Array Ultrashort) mfr 22 cm
Total length (FA 12-Capillary Array Ultrashort) mfr 47 cm
Effective length (FA 12-Capillary Array Short) mfr 33 cm
Total length (FA 12-Capillary Array Short) mfr 55 cm
Effective length (FA 12-Capillary Array Long) mfr 55 cm
Total length (FA 12-Capillary Array Long) mfr 80 cm
Standards, Safety & General Data
Standard Warranty One-year

Description

Construction and series positioning

Performance in operation

Installation and operation

Integration & Operating Notes

Compatibility
Array must match the Fragment Analyzer model and capillary count

The 12-capillary arrays are intended for the 5200/5300/5400 Fragment Analyzer systems; installing an array of the wrong capillary count or format (ultrashort, short, long) will not fit the instrument's capillary drive and will invalidate separation length and sizing performance. Confirm the array format against the installed instrument configuration before ordering.

Consumables brochure 5994-0407EN; Fragment Analyzer brochure 5994-0414EN
Process Limits
Sample concentration must stay within the kit's dynamic range

Quantification is specified from 0.1 ng/µL for DNA fragments and 5 ng/µL for DNA smears, with a DNA fragment concentration range starting at 0.5 ng/µL and a two-orders-of-magnitude input dynamic range. Samples outside this window require dilution; only single dilutions per sample are supported, so plan dilution before loading.

Consumables brochure 5994-0407EN
Maintenance
Replace arrays and reagents within shelf-life and gel capacity

Each array supports two gels, and reagent kits are guaranteed for 4 months at room temperature. Track gel count and reagent expiry per array so that separation resolution (100) and sizing precision (2 % CV) are not degraded by exhausted gels or expired reagents.

Consumables brochure 5994-0407EN
Electrical
No separate electrical supply is specified for the array

The array is a passive consumable; the matched specifications list only a CCD detector and no voltage, current or interface ratings for the array itself. Electrical and control requirements are determined by the host Fragment Analyzer instrument, not by the array.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the 12-capillary array configuration versus a higher-throughput Fragment Analyzer sibling?

Pick the 12-capillary array when daily demand is 12–96 samples run one to three times per day, matching the 5200 system. For one to two 96-well plates up to three times per day choose the 5300; for more than two plates per day with robotic automation choose the 5400.

What adjacent consumables and reagents must be ordered with the array to run a DNA fragment analysis?

The array is supplied separately from the reagent kits; pair it with a DNA/NGS kit such as DNF-473, DNF-474, DNF-476, DNF-477, DNF-905, DNF-910, DNF-915 or DNF-920. Kits cover 500 samples and are room-temperature stable for 4 months.

What maintenance and replacement schedule applies to the array and its reagents?

Each array supports two gels; replace it after the gel capacity is exhausted. Reagent kits carry a guaranteed 4-month shelf life at room temperature, so schedule reagent replacement accordingly to preserve sizing precision of 2 % CV.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Fragment Analyzer Systems: Reliable Results for Nucleic Acid Quality Control
Brochure ·4,8 МБ ·16 pp.
View PDF
PDF
Build Consistency into Your Lab's Workflow
Brochure ·12,3 МБ ·12 pp.
View PDF
PDF
Agilent Fragment Analyzer Consumables
Datasheet ·269,6 КБ ·5 pp.
View PDF