Elmo Rietschle 2BL2061
Elmo Rietschle 2BL2061 — Liquid Ring Vacuum Pumps with Max inlet pressure 101.3 kPa, Motor power 4.35 kW.
The 2BL2061 is a single-stage, oil-free liquid-ring vacuum pump from the L-BL2 series, configured as a compact 'Pump in a Box' with a 4.3 kW (50 Hz) / 4.35 kW (60 Hz) IE3 motor and IP55 protection. It handles inlet pressures up to 1013 mbar and is distinguished within the series by its oil-free operation and air cooling, making it suitable for clean, oil-sensitive vacuum duties. Its primary role is to provide reliable vacuum in systems where contamination-free operation and compact integration are required.
Elmo Rietschle L-BL2 Series — Model Comparison & Selection
| Model | Lubrication type | Operating principle | Motor power, kW | Power supply | Weight, kg | Noise level, dB |
|---|---|---|---|---|---|---|
| 2BL2061 Current | oil-free | liquid ring | 4.3 | 3~ AC | 73 | 64 |
| 2BL2041 | oil-free | liquid ring | — | AC | 69 | — |
| 2BL2101 | oil-lubricated | Venturi | — | AC | — | 78 |
| 2BL2141 | oil-lubricated | liquid ring | 3.4 | AC | 101 | 78 |
| 2BL2251 | oil-free | liquid ring | 5.6 | AC | 76 | 71 |
| 2BL2281 | oil-free | liquid ring | 5.5 | AC | 73 | 78 |
| 2BL2341 | dry | liquid ring | 7 | AC | 261 | — |
| 2BL2501 | oil-lubricated | liquid ring | 15 | AC | 583 | 72 |
Full specifications
| Lubrication type | oil-free |
| Max inlet pressure | 1013 mbar |
| Motor power | 4.3 kW (50 Hz, 380-420 V) 60 Hz, 440-480 V: 4.35 kW |
| Operating principle | liquid ring |
| Number of stages | 1 dimensionless |
| Weight | 73 kg |
| Power supply | 3~ AC (50/60 Hz) |
| Noise level | 64 dB(A) |
| Protection rating | IP55 |
| Cooling type | air |
Description
Construction and series positioning
- Single-stage liquid-ring principle with oil-free lubrication, eliminating oil carryover into the process.
- Compact 'Pump in a Box' design integrates pump, motor, and air cooling into a single unit, reducing installation footprint.
- Within the L-BL2 series, the 2BL2061 sits between the smaller 2BL2041 and the higher-power 2BL2251; unlike the 2BL2101 (Venturi) and 2BL2141 (oil-lubricated), it maintains oil-free operation and a liquid-ring working principle.
- Motor is a 3~ AC IE3 unit rated 4.3 kW at 50 Hz (380–420 V) and 4.35 kW at 60 Hz (440–480 V), with IP55 protection and insulation class F.
Behavior under load and media
- The pump is designed for continuous duty with a maximum inlet pressure of 1013 mbar, allowing operation from atmospheric pressure down to its ultimate vacuum (not specified in the provided data).
- Air cooling ensures heat dissipation without a liquid cooling circuit, simplifying media connections.
- Oil-free operation makes it compatible with processes where oil contamination is unacceptable; the liquid-ring medium (typically water) must be supplied separately and is not integral to the pump.
- Noise level is 64 dB(A), typical for this size of liquid-ring pump.
Installation, connection, and control
- The pump requires a 3-phase AC supply; voltage and frequency must match the motor nameplate (50 Hz: 380–420 V; 60 Hz: 440–480 V).
- IP55 protection allows installation in dusty or wet environments, but the pump should be positioned to allow free air flow for cooling.
- The compact design typically includes suction and discharge ports; piping must be sized to avoid excessive pressure drop and to accommodate the liquid-ring service liquid.
- Control and monitoring (e.g., overload protection) must be provided externally; the data sheet does not specify integrated controls.
Integration & Operating Notes
Applying 50 Hz voltage (380–420 V) to a 60 Hz motor or vice versa will cause overheating, reduced torque, or failure. Verify the actual supply matches the ordered variant before commissioning. The IE3 motor requires proper overload protection set to the full-load current.
The pump is air-cooled and relies on ambient air circulation. Install with minimum clearances around the fan intake and exhaust; do not enclose in a sealed cabinet without forced ventilation. Ambient temperature limits are not specified in the provided data, but typical practice is to avoid exceeding 40 °C.
Although oil-free, the liquid-ring pump requires a continuous service liquid (typically water) supply. Check for adequate flow, temperature, and cleanliness; contaminated liquid can cause wear and reduced performance. Bearings are grease-lubricated for life in many models, but periodic inspection is recommended. Refer to the instruction manual for specific intervals.
Selection & Integration Q&A
Choose 2BL2061 for oil-free liquid-ring duty with 4.3 kW motor, balancing capacity and size. The 2BL2041 is smaller/lower power; the 2BL2251 offers higher power (5.6 kW) for greater capacity. Select 2BL2061 when its flow/pressure curve matches your process and oil-free operation is mandatory.
Provide a 3-phase AC supply matching the motor nameplate: 380–420 V at 50 Hz or 440–480 V at 60 Hz. Use a motor protection circuit breaker or overload relay set to the motor's full-load current (not specified in data sheet). Ensure proper grounding and IP55-compliant connections.
The base pump includes the motor and pump unit but typically excludes service liquid piping, suction/discharge flanges, control panel, and motor protection. A service liquid supply (water) must be provided. Spare parts like seals and bearings are available separately; refer to the manual for scheduled replacement intervals.