Elmo Rietschle 2BL2281
Elmo Rietschle 2BL2281 — Liquid Ring Vacuum Pumps with Motor power 5.5 kW, Pumping speed 25 m³/h.
The 2BL2281 is a single-stage, oil-free liquid ring vacuum pump from the L-BL2 series, configured as a compact 'Pump in a Box' with a 5.5 kW IE3 motor for 3~ 50/60 Hz supply. It delivers 25.0 m³/h at 50 Hz and 29.9 m³/h at 60 Hz, distinguishing it within the series by its higher power and capacity compared to siblings like the 2BL2061 (4.35 kW) and 2BL2141 (3.4 kW). Its primary purpose is oil-free vacuum generation in industrial processes where contamination-free operation and compact integration are required.
Elmo Rietschle L-BL2 Series — Model Comparison & Selection
| Model | Lubrication type | Operating principle | Motor power, kW | Power supply | Weight, kg | Noise level, dB |
|---|---|---|---|---|---|---|
| 2BL2281 Current | oil-free | liquid ring | 5.5 | AC | 73 | 78 |
| 2BL2041 | oil-free | liquid ring | — | AC | 69 | — |
| 2BL2061 | oil-free | liquid ring | 4.3 | 3~ AC | 73 | 64 |
| 2BL2101 | oil-lubricated | Venturi | — | AC | — | 78 |
| 2BL2141 | oil-lubricated | liquid ring | 3.4 | AC | 101 | 78 |
| 2BL2251 | oil-free | liquid ring | 5.6 | AC | 76 | 71 |
| 2BL2341 | dry | liquid ring | 7 | AC | 261 | — |
| 2BL2501 | oil-lubricated | liquid ring | 15 | AC | 583 | 72 |
Full specifications
| Lubrication type | oil-free |
| Motor power | 5.5 kW |
| Operating principle | liquid ring |
| Pumping speed | 25.0 m³/h (50 Hz) 60 Hz: 29.9 m³/h |
| Number of stages | 1 dimensionless |
| Weight | 73 kg |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 78 dB |
| Operating temperature | F |
| Protection rating | IP55 |
| Cooling type | air |
Description
Construction and Series Positioning
- Single-stage liquid ring vacuum pump with oil-free operation, eliminating hydrocarbon contamination in the pumped gas.
- Integrated 'Pump in a Box' design includes the pump, 5.5 kW IE3 motor, and coupling in a compact enclosure, reducing installation footprint.
- IP55 protection rating and air cooling allow operation in dusty or humid environments without additional enclosures.
- Within the L-BL2 series, the 2BL2281 offers higher motor power (5.5 kW) and correspondingly higher pumping speed than the 2BL2061 (4.35 kW) and 2BL2141 (3.4 kW), making it suitable for applications requiring greater capacity. Sibling 2BL2101 uses a Venturi principle and oil lubrication, representing a different technology.
Behavior Under Load and Media
- The liquid ring principle uses a service liquid (typically water) to create the vacuum; the oil-free design means the service liquid contacts the process gas directly, so compatibility of the liquid with the process must be ensured.
- Pumping speed is 25.0 m³/h at 50 Hz and 29.9 m³/h at 60 Hz, providing flexibility for different regional power supplies.
- Noise level is 78 dB, typical for liquid ring pumps of this size; consider acoustic attenuation if installed in noise-sensitive areas.
- No digitized curve points are available in the provided facts, so detailed performance curves (e.g., ultimate pressure vs. flow) should be obtained from the manufacturer for precise system design.
Installation, Connection, and Operation
- The pump requires a 3-phase AC power supply (3~ 50/60 Hz) and must be connected to a suitable motor starter or variable frequency drive (VFD) rated for 5.5 kW. The IE3 motor efficiency class may influence VFD selection and energy consumption.
- Service liquid connections (inlet and outlet) must be provided; the liquid ring pump requires a continuous supply of service liquid during operation. The quality and temperature of the service liquid affect pump performance and must be within manufacturer specifications.
- The compact 'Pump in a Box' design simplifies mounting; ensure the installation location allows sufficient air cooling and access for maintenance. The IP55 rating protects against dust and water jets, but the pump should not be submerged.
- The technical data sheet mentions motor variants (K03-1B, K03-6B, Q03-3B, Q03-7B) and material variants (K, B, R, H); the specific variant for this model must be confirmed on the nameplate to ensure compatibility with the process gas and environment.
Integration & Operating Notes
The 5.5 kW IE3 motor requires a properly sized contactor or motor protection switch with thermal overload and phase-failure protection. Exceeding the motor's service factor or operating on unbalanced phases can cause overheating and winding damage. Verify that the supply voltage matches the motor nameplate (e.g., 400 V at 50 Hz) and that the protection setting is adjusted to the motor's full-load current.
The liquid ring pump requires a continuous service liquid supply (typically water) to form the ring. The liquid must be free of abrasive particles and chemically compatible with the pump materials. High liquid temperature reduces achievable vacuum and pumping speed; ensure the liquid temperature is within the manufacturer's specified range (often below 30 °C for water). Insufficient liquid flow can cause cavitation and loss of capacity.
The compact 'Pump in a Box' design should be mounted on a flat, vibration-resistant surface. Maintain adequate clearance around the enclosure for air cooling; restricted airflow can lead to motor overheating. The IP55 rating allows outdoor installation but avoid direct water spray or immersion. Ensure the service liquid connections are accessible for maintenance.
Although oil-free, the pump's bearings may require periodic lubrication (if grease-lubricated) and the service liquid system should be checked for flow and contamination. Inspect the liquid ring and impeller for wear or deposits. The manufacturer's maintenance schedule should be followed; typically, service intervals depend on operating hours and process conditions. Keep spare service liquid filters and seals on hand as consumables.
Selection & Integration Q&A
Choose the 2BL2281 when you need higher pumping speed (25.0 m³/h at 50 Hz) and a 5.5 kW motor for more demanding applications. The 2BL2061 offers 4.35 kW and lower capacity, while the 2BL2141 has 3.4 kW. Select the 2BL2281 for oil-free operation with greater capacity; choose siblings for lower power or different lubrication.
The pump requires a continuous service liquid (typically water) supply to form the liquid ring. Provide connections for liquid inlet and outlet, and ensure the liquid is clean, compatible with pump materials, and at a temperature that maintains vacuum performance (usually below 30 °C). The liquid flow rate must match the pump's requirements; consult the data sheet for specific flow values. A strainer and flow control valve are recommended.
The pump has IP55 protection, suitable for dusty and humid environments but not for immersion. Ambient temperature and altitude affect motor cooling; ensure adequate ventilation and do not exceed the motor's rated ambient temperature (typically 40 °C). The pump is air-cooled, so keep the enclosure clear. For continuous duty, ensure the service liquid supply is uninterrupted; intermittent operation may require priming. Avoid frequent starts that could overheat the motor.
The base delivery typically includes the pump, motor, and coupling in the enclosure, but not the service liquid piping, valves, strainers, or control panel. A motor starter or VFD, electrical cables, and mounting bolts are also not included. Recommended spares include service liquid filters, shaft seals, and bearings. Consult the manual for a complete list of optional accessories such as vacuum gauges and liquid separators.