Elmo Rietschle 2BL2281
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BL2281

Elmo Rietschle 2BL2281 — Liquid Ring Vacuum Pumps with Motor power 5.5 kW, Pumping speed 25 m³/h.

The 2BL2281 is a single-stage, oil-free liquid ring vacuum pump from the L-BL2 series, configured as a compact 'Pump in a Box' with a 5.5 kW IE3 motor for 3~ 50/60 Hz supply. It delivers 25.0 m³/h at 50 Hz and 29.9 m³/h at 60 Hz, distinguishing it within the series by its higher power and capacity compared to siblings like the 2BL2061 (4.35 kW) and 2BL2141 (3.4 kW). Its primary purpose is oil-free vacuum generation in industrial processes where contamination-free operation and compact integration are required.

Motor power
5.5 kW
Pumping speed
25 m³/h

Elmo Rietschle L-BL2 Series — Model Comparison & Selection

Model Lubrication typeOperating principleMotor power, kWPower supplyWeight, kgNoise level, dB
2BL2281 Current oil-freeliquid ring5.5AC7378
2BL2041 oil-freeliquid ring—AC69—
2BL2061 oil-freeliquid ring4.33~ AC7364
2BL2101 oil-lubricatedVenturi—AC—78
2BL2141 oil-lubricatedliquid ring3.4AC10178
2BL2251 oil-freeliquid ring5.6AC7671
2BL2341 dryliquid ring7AC261—
2BL2501 oil-lubricatedliquid ring15AC58372

Full specifications

Core Performance & Functional Specifications
Lubrication type oil-free
Motor power 5.5 kW
Operating principle liquid ring
Pumping speed 25.0 m³/h (50 Hz)
60 Hz: 29.9 m³/h
Dimensions, Weight & Mechanical Design
Number of stages 1 dimensionless
Weight 73 kg
Electrical, Power & Drive Specifications
Power supply AC (3~ 50/60 Hz)
Operating Conditions, Environment & Protection
Noise level 78 dB
Operating temperature F
Protection rating IP55
Cooling type air

Description

Construction and Series Positioning

Behavior Under Load and Media

Installation, Connection, and Operation

Integration & Operating Notes

Electrical
Motor must be protected against overload and phase loss

The 5.5 kW IE3 motor requires a properly sized contactor or motor protection switch with thermal overload and phase-failure protection. Exceeding the motor's service factor or operating on unbalanced phases can cause overheating and winding damage. Verify that the supply voltage matches the motor nameplate (e.g., 400 V at 50 Hz) and that the protection setting is adjusted to the motor's full-load current.

Technical Data Sheet — L-BL2 2BL2281 IE3 vacuum pump (EN), Edition 06/2017
Process Limits
Service liquid quality and temperature affect vacuum performance

The liquid ring pump requires a continuous service liquid supply (typically water) to form the ring. The liquid must be free of abrasive particles and chemically compatible with the pump materials. High liquid temperature reduces achievable vacuum and pumping speed; ensure the liquid temperature is within the manufacturer's specified range (often below 30 °C for water). Insufficient liquid flow can cause cavitation and loss of capacity.

Technical Data Sheet — L-BL2 2BL2281 IE3 vacuum pump (EN), Edition 06/2017
Mounting
Install on a level surface with sufficient air cooling clearance

The compact 'Pump in a Box' design should be mounted on a flat, vibration-resistant surface. Maintain adequate clearance around the enclosure for air cooling; restricted airflow can lead to motor overheating. The IP55 rating allows outdoor installation but avoid direct water spray or immersion. Ensure the service liquid connections are accessible for maintenance.

Technical Data Sheet — L-BL2 2BL2281 IE3 vacuum pump (EN), Edition 06/2017
Maintenance
Regular inspection of service liquid and bearings is required

Although oil-free, the pump's bearings may require periodic lubrication (if grease-lubricated) and the service liquid system should be checked for flow and contamination. Inspect the liquid ring and impeller for wear or deposits. The manufacturer's maintenance schedule should be followed; typically, service intervals depend on operating hours and process conditions. Keep spare service liquid filters and seals on hand as consumables.

Technical Data Sheet — L-BL2 2BL2281 IE3 vacuum pump (EN), Edition 06/2017

Selection & Integration Q&A

When should I choose the 2BL2281 over other L-BL2 series models like the 2BL2061 or 2BL2141?

Choose the 2BL2281 when you need higher pumping speed (25.0 m³/h at 50 Hz) and a 5.5 kW motor for more demanding applications. The 2BL2061 offers 4.35 kW and lower capacity, while the 2BL2141 has 3.4 kW. Select the 2BL2281 for oil-free operation with greater capacity; choose siblings for lower power or different lubrication.

What are the requirements for the service liquid supply and connections for the 2BL2281?

The pump requires a continuous service liquid (typically water) supply to form the liquid ring. Provide connections for liquid inlet and outlet, and ensure the liquid is clean, compatible with pump materials, and at a temperature that maintains vacuum performance (usually below 30 °C). The liquid flow rate must match the pump's requirements; consult the data sheet for specific flow values. A strainer and flow control valve are recommended.

What environmental and duty-cycle limits apply to the 2BL2281 installation?

The pump has IP55 protection, suitable for dusty and humid environments but not for immersion. Ambient temperature and altitude affect motor cooling; ensure adequate ventilation and do not exceed the motor's rated ambient temperature (typically 40 °C). The pump is air-cooled, so keep the enclosure clear. For continuous duty, ensure the service liquid supply is uninterrupted; intermittent operation may require priming. Avoid frequent starts that could overheat the motor.

What maintenance items and accessories are not included with the base pump?

The base delivery typically includes the pump, motor, and coupling in the enclosure, but not the service liquid piping, valves, strainers, or control panel. A motor starter or VFD, electrical cables, and mounting bolts are also not included. Recommended spares include service liquid filters, shaft seals, and bearings. Consult the manual for a complete list of optional accessories such as vacuum gauges and liquid separators.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BL2 2BL2281 IE3 vacuum pump (EN)
Datasheet ·271,0 КБ ·3 pp.
View PDF