Elmo Rietschle 2BL2501
Elmo Rietschle 2BL2501 — Liquid Ring Vacuum Pumps with Max inlet pressure 101.3 kPa, Motor power 15 kW.
The 2BL2501 is an oil-lubricated liquid ring vacuum pump from the L-BL2 series, configured as a compact 'Pump in a Box' with a 15.0 kW (60 Hz) / 12.4 kW (50 Hz) IE3 motor. It operates at a maximum inlet pressure of 1013 mbar and 1500 rpm at 50 Hz, distinguishing it from oil-free siblings (2BL2041, 2BL2061) and lower-power oil-lubricated models (2BL2141). It is intended for continuous vacuum generation in industrial processes where a liquid ring seal and oil lubrication are acceptable.
Elmo Rietschle L-BL2 Series — Model Comparison & Selection
| Model | Lubrication type | Operating principle | Motor power, kW | Power supply | Weight, kg | Noise level, dB |
|---|---|---|---|---|---|---|
| 2BL2501 Current | oil-lubricated | liquid ring | 15 | AC | 583 | 72 |
| 2BL2041 | oil-free | liquid ring | — | AC | 69 | — |
| 2BL2061 | oil-free | liquid ring | 4.3 | 3~ AC | 73 | 64 |
| 2BL2101 | oil-lubricated | Venturi | — | AC | — | 78 |
| 2BL2141 | oil-lubricated | liquid ring | 3.4 | AC | 101 | 78 |
| 2BL2251 | oil-free | liquid ring | 5.6 | AC | 76 | 71 |
| 2BL2281 | oil-free | liquid ring | 5.5 | AC | 73 | 78 |
| 2BL2341 | dry | liquid ring | 7 | AC | 261 | — |
Full specifications
| Lubrication type | oil-lubricated |
| Max inlet pressure | 1013 mbar |
| Motor power | 12.4 kW (50 Hz) 60 Hz: 15.0 kW |
| Operating principle | liquid ring |
| Rotational speed | 1500 rpm (50 Hz) |
| Weight | 583 kg |
| Power supply | AC |
| Noise level | 72 dB(A) |
| Operating temperature | 20 °C |
| Protection rating | IP55 |
| Cooling type | air |
| Sound pressure level (alt var) mfr | 75 dB(A) |
Description
Construction and positioning
- The 2BL2501 is a liquid ring vacuum pump with oil-lubricated bearings.
- It is part of the L-BL2 series.
- Within the series, this model is the higher-power oil-lubricated variant (15.0 kW at 60 Hz) compared to the 2BL2141 (3.4 kW) and differs from oil-free models (2BL2041, 2BL2061) and the Venturi-type 2BL2101.
Behavior under load and media
- The pump achieves a maximum inlet pressure of 1013 mbar, suitable for rough vacuum applications.
- At 50 Hz, it runs at 1500 rpm with a 12.4 kW motor; at 60 Hz, motor power increases to 15.0 kW.
- Liquid ring operation requires a service liquid (typically water) to form the sealing ring; the oil lubrication is confined to bearings and does not contact the process gas.
- Noise level is 72 dB(A) (75 dB(A) for an alternative variant).
Installation, connection, and control
- The pump is supplied with a 3-phase AC motor, IP55 protection, and is designed for 50/60 Hz operation.
- Ordering codes (e.g., 2BL2501-0□K02-1B) include voltage/frequency substitution codes (K, Q, 3, 6) that must be specified to match the site power supply.
- The compact enclosure simplifies installation, but adequate ventilation and access for maintenance are required.
- Control and monitoring are typically via a motor starter or variable frequency drive; the pump has no integrated sensors or controllers as standard.
Integration & Operating Notes
The 2BL2501 is available with different voltage and frequency configurations (codes K, Q, 3, 6). Applying the wrong supply can cause overheating, reduced performance, or motor failure. Verify the nameplate and ordering code before connection.
The liquid ring requires a continuous supply of service liquid (usually water) at adequate pressure and flow. Contamination or insufficient flow will reduce capacity and may damage the pump. A strainer and flow control are recommended.
The compact 'Pump in a Box' design requires a flat, vibration-free mounting surface and clearance for air cooling. Ambient temperature should be within the specified operating range to avoid overheating.
Oil-lubricated bearings require periodic oil changes per the maintenance schedule. The service liquid system should be inspected for flow and cleanliness. Neglect can lead to bearing failure or reduced vacuum.
Selection & Integration Q&A
Choose the 2BL2501 for higher power (15 kW at 60 Hz) and oil-lubricated reliability in rough vacuum. Select oil-free siblings (2BL2041, 2BL2061) for clean processes, or lower-power 2BL2141 for smaller duties.
The motor is 3-phase AC, 50/60 Hz, with power 12.4 kW (50 Hz) or 15.0 kW (60 Hz). Use a starter or VFD rated for the motor current and voltage code ordered. Ensure supply matches nameplate.
The base delivery includes the pump and motor only. Service liquid piping, strainers, oil for initial fill, and control devices are not included. Order oil and service liquid components separately per the manual.