Technical Data Sheet — L-BV5 2BV5110 IE3 vacuum pump (EN)
Technical Reference Summary
Covered Models & Document Scope
Ficha técnica 2BV5 110: bomba de vacío de anillo líquido en configuración ATEX, gama de modelos L-BV5, tamaño 2BV5110. Variantes: fundición (material K, código de pedido F91) y acero inoxidable (material H, código de pedido F91); variantes de tensión 50 Hz (400 Δ / 690 Y, 500 Δ) y 60 Hz (460 Δ, 575).
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Ultimate inlet pressure | 33 mbar abs. p.1 ↗ | 2BV5110 |
| Cavitation-free operation down to | 80 mbar abs. p.1 ↗ | 2BV5110 |
| Suction capacity | 120 m³/h p.2 ↗ | 2BV5110, 50 Hz, cast iron (K) |
| Suction capacity | 122 m³/h p.2 ↗ | 2BV5110, 50 Hz, stainless steel (H) |
| Suction capacity | 135 m³/h p.2 ↗ | 2BV5110, 60 Hz, cast iron (K) |
| Suction capacity | 138 m³/h p.2 ↗ | 2BV5110, 60 Hz, stainless steel (H) |
| Voltage | 400 Δ / 690 Y V p.2 ↗ | 2BV5110, 50 Hz |
| Voltage | 500 Δ V p.2 ↗ | 2BV5110, 50 Hz |
| Voltage | 460 Δ V p.2 ↗ | 2BV5110, 60 Hz |
| Voltage | 575 V p.2 ↗ | 2BV5110, 60 Hz |
| Current | 9,8 Δ / 5,7 Y A p.2 ↗ | 2BV5110, 50 Hz, 400 Δ / 690 Y |
| Current | 7,8 Δ A p.2 ↗ | 2BV5110, 50 Hz, 500 Δ |
| Current | 11,7 Δ A p.2 ↗ | 2BV5110, 60 Hz, 460 Δ |
| Current | 9,4 A p.2 ↗ | 2BV5110, 60 Hz, 575 |
| Motor power | 4,2 kW p.2 ↗ | 2BV5110, 50 Hz |
| Motor power | 5,6 kW p.2 ↗ | 2BV5110, 60 Hz |
| Service factor | 1,19 - p.2 ↗ | 2BV5110, 50 Hz |
| Service factor | 1,21 - p.2 ↗ | 2BV5110, 60 Hz |
| Efficiency class | IE3 - p.2 ↗ | 2BV5110 |
| Noise level | 61 dB(A) p.2 ↗ | 2BV5110, 50 Hz |
| Noise level | 67 dB(A) p.2 ↗ | 2BV5110, 60 Hz |
| Weight | 120 kg p.2 ↗ | 2BV5110, cast iron (K) |
| Weight | 122 kg p.2 ↗ | 2BV5110, stainless steel (H) |
| Protection rating | IP55 - p.1 ↗ | 2BV5110 |
| Operating liquid quantity | 0,25 / 0,25 m³/h p.2 ↗ | 2BV5110, 50 Hz / 60 Hz, p1 >500 mbar, fresh water |
Operating Limits
- Minimum inlet pressure: 33 mbar abs. p.1 ↗
- Cavitation-free operation minimum inlet pressure: 80 mbar abs. p.1 ↗
- Max. additional water carry-over: 2,50 m³/h p.2 ↗
- Max. back pressure: 1300 mbar abs. p.2 ↗
- Protection rating: IP55 p.1 ↗
- ATEX category: 2G, temperature class T4 inside pump, T3 ambient p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-5 p.2 ↗ | 2BV5 | Pump family L-BV5 liquid ring vacuum pump |
| 6-9 p.2 ↗ | 110 | Size 2BV5110 |
| field after 2BV5110-0 p.2 ↗ | □ | Voltage/frequency variant: D (50 Hz, 400 Δ / 690 Y), 5 (50 Hz, 500 Δ), G (60 Hz, 460 Δ), blank (60 Hz, 575) |
| field after voltage p.2 ↗ | D02 / G03 | Voltage/frequency code: D02 = 50 Hz, G03 = 60 Hz |
| field after frequency code p.2 ↗ | 6B / 5B | Connection variant: 6B for 400 Δ / 690 Y and 460 Δ, 5B for 500 Δ and 575 |