Peter Huber Kältemaschinenbau KISS K20 Kälte-Badthermostat
Peter Huber Kältemaschinenbau ·Made in Germany · In Active Production

Peter Huber Kältemaschinenbau KISS K20 Kälte-Badthermostat

Peter Huber Kältemaschinenbau KISS K20 Kälte-Badthermostat — Thermostatic baths with Noise level 50 dB.

The KISS K20 is a 17-litre refrigerated bath thermostat with a pressure/suction pump and a -30 to 200 °C working range, positioned between the K15 and K25 in the KISS series. Its air-cooled R-290 refrigeration stage delivers 0.4 kW at 20 °C but only 0.065 kW at -30 °C, so it suits sub-ambient and high-temperature bath duties where heat loads are modest at the cold end.

Noise level
50 dB

Direct drop-in replacements

Eppendorf
MixMate ®
53%
match
⚖️ Compare

Peter Huber Kältemaschinenbau KISS Series — Model Comparison & Selection

Model Noise level, dBPower supplyPump connectionTemperature range, °CWeight, kgFilling volume, m³
KISS K20 Kälte-Badthermostat Current 50220-240V 1~/2~ 50/60Hz(Option, #19607)-30–200410.01
KISS K12 Kälte-Badthermostat —110-115V 1~ 50/60Hz(Option, #19607)-20–20028—
KISS K25 Kälte-Badthermostat 50220-240V 1~/2~ 50/60Hz(Option, #19607)-30–200390.015
KISS K6 Kälte-Badumwälzthermostat 57208-240V 1~/2~ 50/60HzM16x1 AG male-25–200250.002
KISS K6s Kälte-Badumwälzthermostat 57208-240V 1~/2~ 50/60HzM16x1 AG male-25–200250.002

Full specifications

Core Performance & Functional Specifications
Noise level 50 dB(A)
Alarm output optic, acoustic
Bath volume 17 l
Dimensions (w × D × H) 350 x 555 x 615 mm
Filling volume 10 l (min.)
Maximum delivery flow rate 14 l/min (pressure pump max.; 0, 25 bar)
Pump connection (Option, #19607) (Option)
Pump speed adjustable no
Pump type Pressure and suction pump, speed not variable
Refrigerator air-cooled, natural refrigerant
Temperature range -30...200 °C
Temperature stability mfr ±0, 05 K
Heating capacity mfr 1, 8 - 2, 1 kW
Delivery capacity suction pump max. mfr 10, 5 l/min (suction pump max.; 0, 17 bar)
Bath opening WxD/BD mfr 290 x 329 / 150
Dimensions, Weight & Mechanical Design
Weight 41 kg
Electrical, Power & Drive Specifications
Power supply 220-240V 1~/2~ 50/60Hz
Current consumption max. mfr 10 + 2 A (max.)
Interfaces, Connections & Control
Controller KISS
Digital interface USB (Device), RS232 Interface
Temperature display OLED Display
Materials, Media & Process Compatibility
Refrigerant R-290 (A3, H220) (1st stage)
Refrigerant quantity 1st stage mfr 0, 072 kg (1st stage)
Operating Conditions, Environment & Protection
Ambient temperature limit 5...40 °C
Protection rating IP20
Cooling capacity mfr 20: 0, 4; 0: 0, 35; -10: 0, 27; -20: 0, 16; -30: (at °C)
Standards, Safety & General Data
Safety class III / FL

Description

Construction and series positioning

The KISS K20 is a benchtop refrigerated bath thermostat with a 17 l bath and a 290 x 329 mm opening (150 mm depth), built around a KISS controller with OLED display. Within the KISS series it sits between the K12/K15 and the K25: the K20 offers more bath volume than the smaller siblings while sharing the 50 dB(A) noise level of the K25, whereas the K6 circulating variant is louder at 57 dB(A). The unit is 350 x 555 x 615 mm and weighs 41 kg.

Thermal behaviour

Installation, control and operation

The refrigeration circuit uses R-290 (A3, H220) with 0.072 kg charge in the first stage and an air-cooled condenser, so ventilation and clearance around the unit are mandatory. Electrical supply is 220–240 V, 1~ or 2~, 50/60 Hz, with maximum current consumption of 10 + 2 A. Control and monitoring are via the KISS controller with OLED display, USB device port and RS232 interface; alarm signalling is optic and acoustic. Overtemperature protection is adjustable per DIN 12876, safety class III/FL, and an autostart function restarts the unit after power failure.

Integration & Operating Notes

Electrical
Supply tolerance is narrow and combined deviations are prohibited

Voltage may deviate by no more than ±5 % and frequency by ±2 %; the combination of -5 % voltage with +2 % frequency is explicitly not allowed. Verify the site supply before connection, especially on generator-fed or weak grids, because simultaneous deviations can damage the compressor.

Datasheet, Installation notes, page 2
Process Limits
Plastic pump is incompatible with acetone and polyglycols

The standard plastic pump is not resistant to acetone or polyglycols (depending on manufacturer). Select an alternative heat transfer fluid or specify a more resistant pump variant at order; otherwise pump failure and fluid contamination are likely.

Datasheet, Operation notes, page 2
Cooling & Media
Use glycol-mixed water for freeze protection below ambient

For operation near or below 0 °C the manufacturer recommends mixing water with glysantine or ethylene glycol rather than using pure water, to prevent freezing and damage to the bath and pump circuit.

Datasheet, Operation notes, page 2
Mounting
Air-cooled condenser requires clearance and cool ambient air

The refrigerating unit is air-cooled; respect the space requirements around the unit and keep ambient temperature between 5 and 40 °C. Cooling capacity may drop when ambient rises above 20 °C, so size the installation for the actual room conditions.

Datasheet, Installation notes, page 2
Control & I/O
External Pt100 is display-only and must be factory-ordered

The Pt100 sensor connection (option #10688) is factory-fitted only and is used to display, not control, an external process temperature. If external monitoring is required, specify it with the order; it cannot be retrofitted later.

Datasheet, Options, page 1
Control & I/O
Autostart after power failure may be unsafe for some processes

An autostart function restarts the unit automatically after a mains interruption. Evaluate whether unattended restart is acceptable for your process and samples; if not, the restart behaviour must be addressed in the site safety concept.

Datasheet, Operation notes, page 1
Electrical
EMC Class A equipment is intended for industrial environments

The unit is classified Class A, Group 1 to EN55011, intended for industrial environments; it may cause interference in residential areas. Coordinate EMC with adjacent sensitive instrumentation if installed outside a dedicated lab zone.

Datasheet, Compliance, page 2

Selection & Integration Q&A

When should I choose the KISS K20 rather than the K15 or K25 siblings?

Pick the K20 when you need a 17 l bath and the -30 to 200 °C range with modest cold-end loads; the K15 offers less bath volume, the K25 more, and the K6 circulating variant is louder at 57 dB(A) versus 50 dB(A).

What electrical supply and protection must be provided for the K20?

A 220–240 V, 1~ or 2~, 50/60 Hz supply rated for the 10 + 2 A maximum current, with voltage within ±5 % and frequency within ±2 %; the combination of -5 % voltage and +2 % frequency is not permitted.

Where can the unit be installed and what ambient conditions apply?

In a dry, protected location (IP20, no water spray) with ambient between 5 and 40 °C and adequate air flow around the air-cooled condenser; cooling capacity may drop above 20 °C ambient, so size for the actual room temperature.

What is not included in base delivery and must be ordered or provided separately?

The Pt100 sensor connection (#10688, display only) and the pump connection option (#19607) are factory options, not standard; the heat transfer fluid and freeze-protection glycol mixture are user-supplied, and the pump is not speed-variable.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
KISS K20 Immersion Circulator
Datasheet ·102,1 КБ ·2 pp.